Alpen HPP X25 AAMA Summaries 04-2014.xlsx

AAMA Test Reports
AAMA Test Report Summaries: X25 Series Windows
When you buy fiberglass super‐insulating Alpen high performance windows, you can rest assured in knowing you are getting windows that meet the standards of AAMA (the American Architectural Manufacturers Association). AAMA a third‐party organization, is a leading window industry source of performance standards and certification. Tests focus on the window's ability to withstand wind loads, water resistance, air infiltration and force entry.
Test Summaries
Description
Performance Grade (Test size)
AAMA/WDMA/CSA 101/I.S.2/A440‐08
AAMA/WDMA/CSA 101/I.S.2/A440‐05
CW‐PG50 (36" x 72")
C‐50 (36" x 72")
ANSI/AAMA/NWWDA 101/I.S.2‐97
LC‐50 (36" x 72")
Results
50.13 psf (2400 Pa)
2 2
0.02 cfm/ft (0.1 L/s/m )
Performance Grade (Test size)
X25 Series Casement Window
Design Pressure psf (Pa)
Air Infiltration @1.57 psf (@75 Pa)
Water Penetration Resistance Test Pressure psf (Pa)
Operating force (in motion) lbf (N)
Forced Entry Resistance (ASTM F‐588)
7.52 psf (360 Pa)
1 lbf (4 N)
Grade 10
Expiration: 07‐14‐15
X25 Series Awning Window
AAMA/WDMA/CSA 101/I.S.2/A440‐08
CW‐PG50 (60" x 36")
AAMA/WDMA/CSA 101/I.S.2/A440‐05
ANSI/AAMA/NWWDA 101/I.S.2‐97
C‐50 (60" x 36")
C‐50 (60" x 36")
Results
Design Pressure psf (Pa)
Air Infiltration @1.57 psf (@75 Pa)
Water Penetration Resistance Test Pressure psf (Pa)
Operating force (in motion) lbf (N)
50.13 psf (2500 Pa)
2 2
<0.01 cfm/ft (0.1 L/s/m )
FForced Entry Resistance (ASTM F‐588)
dE
R i
(ASTM F 588)
G
d 10
Grade 10
Expiration: 02‐15‐16
X25 High Profile (HP) Picture Window
AAMA/WDMA/CSA 101/I.S.2/A440‐08
AAMA/WDMA/CSA 101/I.S.2/A440‐05
ANSI/AAMA/NWWDA 101/I.S.2‐97
Design Pressure psf (Pa)
Air Infiltration @1.57 psf (@75 Pa)
Water Penetration Resistance Test Pressure psf (Pa)
Operating force (in motion) lbf (N)
Forced Entry Resistance (ASTM F‐588)
X25 Low Profile (LP) Picture Window
AAMA/WDMA/CSA 101/I.S.2/A440‐08
AAMA/WDMA/CSA 101/I.S.2/A440‐05
ANSI/AAMA/NWWDA 101/I.S.2‐97
Design Pressure psf (Pa)
Air Infiltration @1.57 psf (@75 Pa)
Water Penetration Resistance Test Pressure psf (Pa)
Operating force (in motion) lbf (N)
Forced Entry Resistance (ASTM F‐588)
7.52 psf (360 Pa)
<1.0 lbf (<5 N)
CW‐PG45 (60" x 60")
C‐45 (60" x 60")
C‐45 (60" x 60")
CW‐PG35 (72" x 96")
C‐35 (72" x 96")
C‐35 (72" x 96")
Results
45.11 psf (2160 Pa)
2 2
0.02 cfm/ft (0.05 L/s/m )
Results
35.09 psf (1680 Pa)
<0.01 cfm/ft2 (<0.05 L/s/m2 )
15.04 psf (720 Pa)
N/A
Grade 40
Expiration: 05‐11‐15
7.52 psf (360 Pa)
N/A
Grade 40
Expiration: 05‐12‐15
CW‐PG70 (60" x 60")
CW‐PG45 (72" x 96")
C‐70 (60" x 60")
C‐70 (60" x 60")
Results
C‐45 (72" x 96")
C‐45 (72" x 96")
Results
70.18 psf (3360 Pa)
2 2
<0.01 cfm/ft (<0.05 L/s/m )
45.11 psf (2160 Pa)
<0.01 cfm/ft2 (<0.05 L/s/m2 )
12.11 psf (580 Pa)
7.52 psf (360 Pa)
N/A
Grade 40
Expiration: 10‐26‐15
N/A
Grade 40
Expiration: 10‐25‐15
Alpen HPP, LLC | www.AlpenHPP.com | [email protected] | Ph: 303.834.3600 | 800.882.4466 | Fax: 303.834.3541 | 12‐2013
AAMA Test Reports
AAMA Test Report Summaries: X25 Series Windows
***Single‐hung, double‐hung and horizontal slider styles are available only in 525 and 725 Series.
Test Summaries
Description
Performance Grade (Test size)
AAMA/WDMA/CSA 101/I.S.2/A440‐08
LC‐PG50 (55" x 91")
AAMA/WDMA/CSA 101/I.S.2/A440‐05
ANSI/AAMA/NWWDA 101/I.S.2‐97
C‐50 (55" x 91")
C‐50 (55" x 91")
Results
50.13 psf (2400 Pa)
2 2
0.11 cfm/ft (0.6 L/s/m )
Performance Grade (Test size)
X25 Single‐hung Window
Design Pressure psf (Pa)
Air Infiltration @1.57 psf (@75 Pa)
Water Penetration Resistance Test Pressure psf (Pa)
Operating force (in motion) lbf (N)
Forced Entry Resistance (ASTM F‐588)
7.52 psf (360 Pa)
35 lbf (155 N)
Grade 20
Expiration: 05‐16‐15
X25 Double‐hung Window ‐ Standard performance
AAMA/WDMA/CSA 101/I.S.2/A440‐08
LC‐PG50 (40" x 63")
AAMA/WDMA/CSA 101/I.S.2/A440‐05
ANSI/AAMA/NWWDA 101/I.S.2‐97
LC‐50 (40" x 63")
Results
Design Pressure psf (Pa)
Air Infiltration @1.57 psf (@75 Pa)
Water Penetration Resistance Test Pressure psf (Pa)
Operating force (in motion) lbf (N)
Forced Entry Resistance (ASTM F‐588)
50.13 psf (2400 Pa)
2 2
0.16 cfm/ft (0.81 L/s/m )
7.52 psf (360 Pa)
22 lbf (98 N)
Grade 10
Expiration: 01 22 2016
Expiration: 01‐22‐2016
X25 Double‐hung Window ‐ Optional request for CW performance model (special quote required)
AAMA/WDMA/CSA 101/I.S.2/A440‐08
CW‐PG30 (55" x 91")
ANSI/AAMA/NWWDA 101/I.S.2‐97
Design Pressure psf (Pa)
Air Infiltration @1.57 psf (@75 Pa)
Water Penetration Resistance Test Pressure psf (Pa)
Operating force (in motion) lbf (N)
Forced Entry Resistance (ASTM F‐588)
C‐30 (55" x 91")
Results
30.08 psf (1440 Pa)
2 2
0.16 cfm/ft (0.8 L/s/m )
7.52 psf (360 Pa)
34 lbf (151 N)
Grade 20
Expiration: 01‐22‐2016
X25 Horizontal Slider Window (2‐panel)
AAMA/WDMA/CSA 101/I.S.2/A440‐08
AAMA/WDMA/CSA 101/I.S.2/A440‐05
ANSI/AAMA/NWWDA 101/I.S.2‐97
Design Pressure psf (Pa)
Air Infiltration @1.57 psf (@75 Pa)
Water Penetration Resistance Test Pressure psf (Pa)
Operating force (in motion) lbf (N)
Forced Entry Resistance (ASTM F‐588)
R‐PG25 (72" x 48")
R‐25 (72" x 48")
Results
25.06 psf (1200 Pa)
2 2
0.10 cfm/ft (0.51 L/s/m )
3.76 psf (180 Pa)
8 lbf (36 N)
Grade 10
Expiration: 08‐25‐16
X25 Horizontal Slider Window (3‐panel)
Tested unit configuration:
AAMA/WDMA/CSA 101/I.S.2/A440‐08
AAMA/WDMA/CSA 101/I.S.2/A440‐05
1/3 ‐ 1/3 ‐ 1/3
Tested window size qualifies
ANSI/AAMA/NWWDA 101/I.S.2‐97
1/4 ‐ 1/2 ‐ 1/4 at tested
window size.
Design Pressure psf (Pa)
Air Infiltration @1.57 psf (@75 Pa)
Water Penetration Resistance Test Pressure psf (Pa)
Operating force (in motion) lbf (N)
Forced Entry Resistance (ASTM F‐588)
R‐PG25 (XOX 132" x 48")
CW‐PG30 (XOX 108" x 60")
R‐25 (XOX 132" x 48")
R‐25 (XOX 132" x 48")
Results
C‐30 (XOX 108" x 60")
C‐30 (XOX 108" x 60")
Results
25.06 psf (1200 Pa)
2 2
0.09 cfm/ft (0.5 L/s/m )
30.08 psf (2400 Pa)
0.09 cfm/ft2 (0.5 L/s/m2 )
3.76 psf (180 Pa)
13 lbf (58 N)
Grade 10
Expiration: 08‐02‐15
5.43 psf (260 Pa)
12 lbf (53 N)
Grade 10
Expiration: 10‐25‐15