CELL-tainer single-use bioreactor for microbial fermentation and cell cultures – CM200US / CM200EU The CELL-tainer ® bioreactor system provides accurate, low shear mixing and high mass transfer rates. Mixing of cell cultures is essential to create and maintain homogenous conditions in the bioreactor. The single-use bioreactor bag is positioned in the tray and placed on the rocking platform creating a two-dimensional movement (including a wave like motion) in the culture medium. The rocker angle and frequency can be adjusted to increase or decrease the mixing time and the oxygen transfer rate. The CELL-tainer ® control system has three password protected access levels. The access to the local human interface can be blocked by the supervisory software allowing the system to be used in compliance with 21 CFR part 11. The robust design and heavy-duty motor guarantee years of trouble-free operation at extreme low noise levels. Specifications System specifications - CM200US/CM200EU Dimensions unit W x H x D = 3500 x 1670 x 1750 mm (approx.) (Height excl. signal light is 1500 mm) Weight (empty) 1100 kg (approx.) Floorload < 210 kg/m2 under operation Dimensions bag or shaker platform W x H x D = 1400 x 1000 x 200 mm (approx.) Light protection Closed cabinet. The top sections of the cabinet can be shift to side in order to load the bag. Internal view is possible with camera mounted inside. Movement profile 20 movement: horizontal displacement combined with vertical displacement. Tilt angle is manually adjustable. Tilt angle: 7 steps from 5.35 – 14.41°; positioning in steps of 1.28° Rotational speed 1– 30 rpm; resolution 1 rpm; accuracy 0.3 rpm Temperature control Sensor on platform, directly under the bag; accuracy ± 0.2º C Control range: 20 – 40º C (under ambient temperature conditions) Resolution: 0.5º C Heating/cooling capacity Temperature control by heat-exchanger (water-filled) underneath the bag, connected to a thermo-circulator (electrical heater / chiller, integrated in the CELL-tainer-system). Heating capacity: 5 KW. Cooling capacity: 2.4 KW DO measurement Dissolved Oxygen amplifier with polarographic electrode to be positioned into a separate membrane plug mounted in the bottom of the bag. 5 – 150% air saturation (± 5% air saturation). Air flow control by mass flow controller (HTK) 0 – 200 Ln/min DO control (PID) Mass flow controllers (HTK), 0 – 50 Ln/min O2, 0 – 50 Ln /min N2 pH measurement pH – amplifier with disposable electrochemical sensor fixed mounted in the bottom of the bag. pH = 2.00 – 10.00 (± 0.03 unit) pH control (PID) Alkaline: Peristaltic pump Watson-Marlow, 24VDC, 45 rpm Watson-Marlow Pumphead 313: applicable with 1.6mm wall tube Complete with adjustable tube clamps for 0.5 mm to 8.0 mm ID tubing Acid: Peristaltic pump Watson-Marlow, 24VDC, 45 rpm Watson-Marlow Pumphead 313: applicable with 1.6mm wall tubing Complete with adjustable tube clamps for 0.5 mm to 8.0 mm ID tubing or Mass flow controller (CO2) 0 – 50 Ln/min Air supply 1 – 6 barg. Additional gasses (O2, N2): 1 – 2 barg. Gasses internally reduced to 0.1 barg max. Maximum bag pressure (operating) 0.12 barg Exhaust gas Easy-Load filter heater for exhaust gas filter. Maximum setpoint 15º C above culture temperature; cut-off at 50º C 170 mm 1750 mm Bag specifications – CB-260L-CELL Film materialClear-Pak® film Ultra Low Density Polyethylene (ULDPE) Outer Layer EVOH Gas Barrier Layer 1500 mm Ultra Low Density Polyethylene (ULDPE) Contact Layer 3500 mm Process monitoring and control Single Board panel PC (B&R) with I/O cards PP5OO Display 15" XGA display touchscreen Data storage and operation - Measuring rpm. T, DO, pH (adjustable sampling time) - Data storage / batch - Alarm logs: door open, change set-points, not reaching set-point, sensor failure - Dose monitoring: show total sec/ml or percent in the Process View screen - Manual operation of valves and pumps - Manual position of tray (jog, sample, drain) Data export USB interface (csv. file) Safety Door opening / safety switch (stop) on all functions Protection CE/ IP54 Power EU: 400 VAC, 50hz, (3 Phase, 0, ground) 16 A NA: To be specified by order Manuals Operation and Installation The CELL-tainer software consists of: • Process Parameters: - PID factors, dead zone for pH, %DO (including rpm cascade with 02) and temperature control - PID set points and motor speed - Constant outputs actuators • Measurements and control of pH, %DO and temperature Charter Medical’s Clear-Pak® bio-containers are designed for applications in processing, handling, storage and transport of sterile fluids. Clear-Pak® is a single web film in a multilayer, co-extruded format with an Ultra Low Density Polyethylene (ULDPE) contact layer, EVOH gas barrier layer, and Polyethylene (PE) outer layer. The film thickness is 13 mil and offers superior clarity, excellent gas barrier properties and is animal derivative component free. Complex validation package available upon request. Sealing Heat sealing Sterilization Gamma irradiation Sensor mounting Mounted through 2 bottom plugs: polycarbonate • disposable pH sensor, fixed mounted • disposable DO sensor, fixed mounted Bag positioning Via 2 bottom plugs: polycarbonate Connections top • 3x addition, C-Flex® 1/4" x 3/8", + female luerlock and (male) cap • 1x gas inlet line, Silicone 1/2" x 3/4" including filter, 0.2µm • 1x gas outlet line, Silicone 1/2" x 3/4" including filter, 0.2µm • A 1 1/2" Tri-clover port in the gas-outline line prevents liquid being forced into this line. • 1x diptube line: sample-septum (luer, swabable valve) Connections bottom 1x drain line, C-Flex®, 1/2" x 3/4", press-in-plug Size 1320mm x 1000 mm Physical Test Data (post gamma irradiation*) Property Test Protocol Tensile Strength ASTM D882 Yield Strength ASTM D882 Elongation at Break ASTM D882 Elastic Modulus ASTM D882 Tear Resistance ASTM D1004 Penetration Resistance ASTM F1306 ASTM D3985 O2 Transmission Rate ASTM F2476 CO2 Transmission Rate Moisture Vapor Transmission Rate ASTM F1249 Clarity ASTM D1003 Haze ASTM D1003 Transmittance ASTM D1003 Operating Range Average Value 1900 psi 1200 psi 460% 39,000 psi 5.25 lb 4.94 in.lb <0.003 cc/100in2-day-atm <0.01 cc/100in2-day-atm 0.021 g/100in2-day 97% 7% 93% -80ºC to 50ºC • Activation of valves and pumps: O2, N2, Base and Acid / CO2 and Feed • Feed control: a)auto-feed, on timer basis b)on basis of DO% (feed reduction, to prevent anaerobic conditions in the culture) • Alarms and Events: Stop, Start, Emergency Stop, Opening Door, Sensor Failure, Motor Failure, Parameters too Low / High • Safety: when the motor is running, the covers (sliding left and right) are secured (locked). When released, covers can be opened and the bag can be positioned. • System settings: IP address, screensaver, log interval, volume factors The CELL-tainer life cycle is according to Laboratory equipment Category D/E. Biocompatibility Test Data (post gam ma irradiation*) Property USP Class VI Cytotoxicity Bacteria Endotoxin Heavy Metals Buffering Capacity Non-Volatile Residue (NVR) Residue on Ignition Appearance Acidity and Alkalinity Absorbance Reducing Substances Local Effects After Implantation Irritation and Delayed-type Sensitivity Systemic Toxicity Particulates Test Protocol USP <88> USP <87> USP <85> USP <661> USP <661> USP <661> USP <661> EP <3.1.5> EP <3.1.5> EP <3.1.5> EP <3.1.5> ISO 10993-6 ISO 10993-10 ISO 10993-11 USP <788> Value Pass Pass Pass Pass < 1 mL < 1 mg Pass Pass Pass 0.01,Pass 0.02 mL, Pass Pass Pass Pass Pass *Gamma Irradiation Level; Minimum 25 kGy 3948-A Westpoint Blvd., Winston-Salem, NC 27103, USA Toll Free: 866.458.3116 | Fax: 336.714.4241 | www.chartermedical.com is owned by Lydall, Inc. and/or its subsidiaries and is registered at least in the US. CELL-tainer ® is owned by Cellution Biotech B.V. Watson-Marlow is owned by Watson-Marlow Pumps Group ® C-Flex is owned by Saint-Gobain Performance Plastics ® Clear-Pak is owned by Charter Medical, Ltd. and is registered at least in the US. All data and statements concerning these products may be considered as being indicative of representative properties and characteristics obtainable. We make no warranty, express or implied, concerning actual use or results because of industry specific influences.
© Copyright 2024 ExpyDoc