0.0 44 34 32 22 22 35 0.1Cu (LV) 0.05Cu 3c (LV) 68 0.1Cu (LV) 7/16/3(LV) 45 46 46 0.06Cu 3c (LV) 0.1Cu (LV) 33 34 35Al/CuCNE (LV) running at 1ph 0.1Cu (LV) 23 7 BROWNLOW STREET 23 0.05Cu 3c (LV) 0.06Cu (LV) 14 ) 0.06Cu 3c (LV 12 70CNE (LV) 24 GRANVILLE STREET 0.05Cu 3c (LV) CAMPION GREE 1ph Unknown 0.1Cu (LV) N 13 2 1 0.06Cu 3c (LV) ) 0.06Cu 3c (LV 1 0.05Cu 3c (LV) 0.1Cu (LV) 22 20 0.1Cu (LV) 13 14 20 12 95Al/CuCNE (LV) 185 CU 33 185Cu (33kV,decom) 0.15 CU 33kV pilot 185 CU 33kV Campion Court 1 2 0.1Cu (LV) 0.1 CU 11kV 185 3c Al/Cu CNE 02/2014 0.15 CU 33kV depth 1.00m 185 3c Al/Cu CNEROAD Ass. Route 10/2012 CAMPION 0.2Cu (LV) SJT 0.2Cu (LV) 0.2 4c CU SJT 35 Hyb 0.2 4c CU 59 53 2Cu (LV) 35 Hyb AR 41 0.3AL (LV) 185 CU 33kV 3 x 150 1c Cu XLPE 33kV 04/2010 [o] 185 CU 33kV 185 CU 33kV 0.2Cu (LV) S.T.A. 55 0.1 CU 11kV 0.1 CU 11kV 0.0225 2c CU AR Cable Route Unknown 57 1ph Unknown LE 27 1ph Unknown AR 15 0.2Cu (LV) 0.1 CU 11kV 0.1 CU 11kV 0.1Cu (LV) 0.1Cu (LV) 0.2Cu (LV) 0.2Cu (LV) S.T.A. 0.3AL (LV) 0.3AL (LV) 93/2577 (42D2045) HAZEL CLOSE El PLEASANT WAY 6 x 0.3Al + 1 x 0.2Cu (LV) Tails 34 Sub 35CNE (LV) Sta 1 15 18 185Al/CuCNE (LV) E JASMINE GROV 14 5 14 Z HA 12 EL 14 SE 24 CLO AL (LV ) 12 8 ) 0.3 26 E CN (LV 35 9 PL03 UNSET ROUTE UNKNOWN 7 6 2 Recreation Ground U/K 1ph 35 Hyb 30a 0.0225 2c CU Cable Route Unknown Warning: PDF designed for colour print only with no page scaling. This Information is given as a guide only and its accuracy cannot be guaranteed 23 27 5Al/CuCNE (LV) 95Al/CuCNE (LV) Link Box Approx. Scales: 1:1250 Area or Circle dig site 1:500 Line dig site S LV HV (11kV) Line/Area Date Requested: 10/04/2014 Job Reference: 1151416 Site Location: 432289 266630 Requested by: MR Stephan Parra Your Scheme/Reference: n/a SURF Telecoms PL Service Site Location Contact Us Mapping Enquiries: All areas 0121 623 9780 General Enquiries: Midlands 0845 724 0240 South Wales 0845 601 3341 South West 0845 601 2989 Underground Cable Overhead Line 0.06Cu (LV) S Pilot Cables P P PME Earth Pole Mounted Transformer Underground Earth Ground Mounted Transformer HV (33kV) HV (66kV) HV (132kV) E * Advice should be sought from the Western Power Distribution General Enquiries team for any work that is to take place in proximity to 132kV underground cables and 132kV overhead lines IMPORTANT NOTICES These plans are provided as a general guide only. Services or recent additions to the network may not be shown. Cables, overhead lines & substations owned by other electricity network owners or private companies may be present but will not be shown. You should always verify exact locations of cables using a cable locator and by careful use of hand tools in accordance with HSE guidance note HSG47. When working within 10m of any overhead electric line you should follow the requirements of HSE Guidance Note GS6. For further advice on working near our electricity cables or lines, call our General Enquiries number. Report damage immediately – KEEP EVERYONE AWAY FROM THE AREA East Mids 0800 056 8090 West Mids 0800 328 1111 South Wales 0800 052 0400 South West 0800 365 900 Crown Copyright © All Rights Reserved. Ordnance Survey Licence numbers: EL27318X, 100024877 and 100021807. WPD Copyright: This copy has been made by or with the authority of Western Power Distribution (WPD) pursuant to Section 47 of the Copyright Designs and Patents Act 1988 unless that Act provides a relevant exception to copyright the copy must not be copied without the prior permission of the copyright owner Plans generated by DigSAFE Pro (tm) software provided by PelicanCorp
© Copyright 2024 ExpyDoc