Autolimiter® II Automatic Overfill Prevention Valve

SERVICE STATION HARDWARE
UNDERGROUND STORAGE TANK EQUIPMENT
Autolimiter II
Automatic Overfill
Prevention Valve
®
The EBW® brand Autolimiter® overfill prevention valve is a self
contained two-stage positive shut-off valve designed to prevent
the overfill of an underground storage tank (UST) during a gravity
fed product delivery. When the liquid level of the UST reaches
about 92% of the tank capacity during a fill, the product in the tank
raises the lower float of the valve. The primary poppet of the valve
is then released and reduces flow to about 10% of normal flow. The
sudden reduction in flow created by the closing of the primary
poppet provides “line shock” to the fill hose notifying the transport
delivery driver the tank is nearing 95% capacity. The transport
delivery driver can then stop filling the tank, disconnect and drain
the delivery hose. The upper float will close off the product flow
when the product level reaches 95% of the tank capacity.
Highlights
•Two-stage, spring-loaded shut-off flapper reduces line
shock.
•Vertical float design allows for valve to be removed
even when tank is full.
•Inspection test port.
•Bottom tube threads on (except for -04 models).
•Designed solely for use in underground storage tanks.
For gravity drops only. No attempt should be made to
utilize this product with aboveground storage tanks.
The valve would not function, creating a very
dangerous condition.
Specifications
Approvals
•ULC listed.
•CARB approved.
Dimensions
60"
1,524 mm
Cut To Length
and Field
Flare
Factory Flared
Top Tube
Assembly
Cut To
Length and
Field Install
60"
1,524 mm
Factory
Installed Top
Tube Assembly
•EVR Phase 1 models require T-6100-FT installation tool.
•Biofuel compatible model options feature hard coat
anodized valve body and Viton seals.
15.5"
393 mm
96" / 120"
2,438 mm /
3,048 mm
Valve
Assembly
Thread On
Bottom
Assembly
All Non-CARB Models
15.5"
393 mm
96" / 120"
2,438 mm /
3,048 mm
All CARB Models
Valve
Assembly
Thread On
Bottom
Assembly
SERVICE STATION HARDWARE
UNDERGROUND STORAGE TANK EQUIPMENT
Specifications continued
Installation Dimensions
Top of Riser
Seamless
Flanged Top
Tube
Factory
Supplied
Aluminum
Tubing Seals
to OD of
Valve
A
2nd Stage
Float
Riser Pipe
Top of Tank
C
1st Stage
Float
95%
16" (406 mm)
Aluminum
Thread On
Lower Drop
Tube (To be
Field Cut)
B
Bottom of Tank
6" (152 mm) Standard Spacing or Per Local Code
Note: EVR valves require faring tool.
Model
708-491-01
708-491-02
708-491-11
708-491-31
708-491-12
708-491-32
708-491-21
708-492-01
708-492-02
708-492-11
708-492-31
708-492-12
708-492-32
708-493-03
708-493-04
708-493-23
708-493-24
708-492-22
708-494-XX
A
In.
60
60
60
60
60
60
60
120
120
120
120
120
120
78
78
78
78
120
Valve only
B
mm
1524
1524
1930
1930
1930
1930
1524
3048
3048
3048
3048
3048
3048
981
981
981
981
3048
In.
96
120
96
96
120
120
96
96
120
96
96
120
120
96
120
96
120
120
C
mm
2438.4
3048
2438.4
2438.4
3048
3048
2438.4
2438.4
3048
2438.4
2438.4
3048
3048
2438.4
3048
2438.4
3048
3048
In.
172
196
172
172
196
196
172
232
256
216
216
240
240
172
196
190
214
256
mm
4368.8
4978.4
4368.8
4368.8
4978.4
4368.8
4368.8
5892.8
6502.4
5486
5486
6096
6096
4368.8
4978.4
4826
5435.6
6502.4
SERVICE STATION HARDWARE
UNDERGROUND STORAGE TANK EQUIPMENT
Ordering Information
Model
708-491-01
708-491-02
708-491-11*
708-491-31**
708-491-12*
708-491-32**
708-491-21***
708-492-01
708-492-02
708-492-11*
708-492-21***
708-492-22**
708-492-31**
Description
Dual point Autolimiter® II overfill prevention valve
Dual point Autolimiter® II overfill prevention valve
Dual point Autolimiter® II overfill prevention valve
Dual point Autolimiter® II overfill prevention valve
Dual point Autolimiter® II overfill prevention valve
Dual point Autolimiter® II overfill prevention valve
Dual point Autolimiter® II overfill prevention valve
Dual point Autolimiter® II overfill prevention valve
Dual point Autolimiter® II overfill prevention valve
Dual point Autolimiter® II overfill prevention valve
Dual point Autolimiter® II overfill prevention valve
Dual point Autolimiter® II overfill prevention valve
Dual point Autolimiter® II overfill prevention valve
708-492-12*
708-492-32**
708-493-03
708-493-04
708-493-23
708-493-24
708-340-901
708-494-02
708-494-03
708-494-04
708-498-01
708-498-02
708-498-03
708-498-11***
Dual point Autolimiter® II overfill prevention valve
Dual point Autolimiter® II overfill prevention valve
Coaxial Non-Poppet Autolimiter® II overfill prevention valve
Coaxial Non-Poppet Autolimiter® II overfill prevention valve
Poppeted coaxil adaptor, tube Autolimiter®: 6.5' top 8" bottom
Poppeted coaxil adaptor, tube Autolimiter® kit: 6.5' top 8" bottom
Poppeted Coax Tightening Tool
Dual point utolimiter® II valve only
Coaxial utolimiter® II valve only
Dual point valve/adapter kit
Installation kit - dual point
Installation kit - CARB EVR
Installation kit - coaxial
Installation kit - dual point AGB
*CARB EVR Phase 1 Certification VR-101 for gas, factory installed top tube to valve body.
**CARB EVR Phase 1 Certification VR-101 for gas/E85, factory installed top tube to valve body.
***Biofuel Compatible (E-85/Biodiesel).
A Franklin Fueling Systems Brand
franklinfueling.com
3760 Marsh Rd. • Madison, WI 53718, USA
Tel: +1 608 838 8786 • Fax: +1 608 838 6433
Tel: USA & Canada +1 800 225 9787 • Tel: UK +44 (0)1473 243300
Tel: Mex 001 800 738 7610 • Tel: FR +33 (0)1 69 21 41 41 • Tel: CH +86 10 8565 4566
FFS-0275 07-14
Overall Length
172.00 in. / 4368.8 mm
196.00 in. / 4978.4 mm
172.00 in. / 4368.8 mm
172.00 in. / 4368.8 mm
196.00 in. / 4978.4 mm
196.00 in. / 4978.4 mm
172.00 in. / 4368.8 mm
232.00 in. / 5892.8 mm
256.00 in. / 6502.4 mm
216.00 in. / 5486.0 mm
216.00 in. / 5486.0 mm
256.00 in. / 6502.4 mm
216.00 in. / 5486.0 mm
240.00 in. / 6096.0 mm
240.00 in. / 6096.0 mm
172.00 in. / 4368.8 mm
196.00 in. / 4978.4 mm
190 in / 4826 mm
214 in / 5435.6 mm
N/A
Rivet on
Rivet on
Rivet on
N/A
N/A
N/A
N/A