SERVICE STATION HARDWARE UNDERGROUND STORAGE TANK EQUIPMENT Autolimiter II Automatic Overfill Prevention Valve ® The EBW® brand Autolimiter® overfill prevention valve is a self contained two-stage positive shut-off valve designed to prevent the overfill of an underground storage tank (UST) during a gravity fed product delivery. When the liquid level of the UST reaches about 92% of the tank capacity during a fill, the product in the tank raises the lower float of the valve. The primary poppet of the valve is then released and reduces flow to about 10% of normal flow. The sudden reduction in flow created by the closing of the primary poppet provides “line shock” to the fill hose notifying the transport delivery driver the tank is nearing 95% capacity. The transport delivery driver can then stop filling the tank, disconnect and drain the delivery hose. The upper float will close off the product flow when the product level reaches 95% of the tank capacity. Highlights •Two-stage, spring-loaded shut-off flapper reduces line shock. •Vertical float design allows for valve to be removed even when tank is full. •Inspection test port. •Bottom tube threads on (except for -04 models). •Designed solely for use in underground storage tanks. For gravity drops only. No attempt should be made to utilize this product with aboveground storage tanks. The valve would not function, creating a very dangerous condition. Specifications Approvals •ULC listed. •CARB approved. Dimensions 60" 1,524 mm Cut To Length and Field Flare Factory Flared Top Tube Assembly Cut To Length and Field Install 60" 1,524 mm Factory Installed Top Tube Assembly •EVR Phase 1 models require T-6100-FT installation tool. •Biofuel compatible model options feature hard coat anodized valve body and Viton seals. 15.5" 393 mm 96" / 120" 2,438 mm / 3,048 mm Valve Assembly Thread On Bottom Assembly All Non-CARB Models 15.5" 393 mm 96" / 120" 2,438 mm / 3,048 mm All CARB Models Valve Assembly Thread On Bottom Assembly SERVICE STATION HARDWARE UNDERGROUND STORAGE TANK EQUIPMENT Specifications continued Installation Dimensions Top of Riser Seamless Flanged Top Tube Factory Supplied Aluminum Tubing Seals to OD of Valve A 2nd Stage Float Riser Pipe Top of Tank C 1st Stage Float 95% 16" (406 mm) Aluminum Thread On Lower Drop Tube (To be Field Cut) B Bottom of Tank 6" (152 mm) Standard Spacing or Per Local Code Note: EVR valves require faring tool. Model 708-491-01 708-491-02 708-491-11 708-491-31 708-491-12 708-491-32 708-491-21 708-492-01 708-492-02 708-492-11 708-492-31 708-492-12 708-492-32 708-493-03 708-493-04 708-493-23 708-493-24 708-492-22 708-494-XX A In. 60 60 60 60 60 60 60 120 120 120 120 120 120 78 78 78 78 120 Valve only B mm 1524 1524 1930 1930 1930 1930 1524 3048 3048 3048 3048 3048 3048 981 981 981 981 3048 In. 96 120 96 96 120 120 96 96 120 96 96 120 120 96 120 96 120 120 C mm 2438.4 3048 2438.4 2438.4 3048 3048 2438.4 2438.4 3048 2438.4 2438.4 3048 3048 2438.4 3048 2438.4 3048 3048 In. 172 196 172 172 196 196 172 232 256 216 216 240 240 172 196 190 214 256 mm 4368.8 4978.4 4368.8 4368.8 4978.4 4368.8 4368.8 5892.8 6502.4 5486 5486 6096 6096 4368.8 4978.4 4826 5435.6 6502.4 SERVICE STATION HARDWARE UNDERGROUND STORAGE TANK EQUIPMENT Ordering Information Model 708-491-01 708-491-02 708-491-11* 708-491-31** 708-491-12* 708-491-32** 708-491-21*** 708-492-01 708-492-02 708-492-11* 708-492-21*** 708-492-22** 708-492-31** Description Dual point Autolimiter® II overfill prevention valve Dual point Autolimiter® II overfill prevention valve Dual point Autolimiter® II overfill prevention valve Dual point Autolimiter® II overfill prevention valve Dual point Autolimiter® II overfill prevention valve Dual point Autolimiter® II overfill prevention valve Dual point Autolimiter® II overfill prevention valve Dual point Autolimiter® II overfill prevention valve Dual point Autolimiter® II overfill prevention valve Dual point Autolimiter® II overfill prevention valve Dual point Autolimiter® II overfill prevention valve Dual point Autolimiter® II overfill prevention valve Dual point Autolimiter® II overfill prevention valve 708-492-12* 708-492-32** 708-493-03 708-493-04 708-493-23 708-493-24 708-340-901 708-494-02 708-494-03 708-494-04 708-498-01 708-498-02 708-498-03 708-498-11*** Dual point Autolimiter® II overfill prevention valve Dual point Autolimiter® II overfill prevention valve Coaxial Non-Poppet Autolimiter® II overfill prevention valve Coaxial Non-Poppet Autolimiter® II overfill prevention valve Poppeted coaxil adaptor, tube Autolimiter®: 6.5' top 8" bottom Poppeted coaxil adaptor, tube Autolimiter® kit: 6.5' top 8" bottom Poppeted Coax Tightening Tool Dual point utolimiter® II valve only Coaxial utolimiter® II valve only Dual point valve/adapter kit Installation kit - dual point Installation kit - CARB EVR Installation kit - coaxial Installation kit - dual point AGB *CARB EVR Phase 1 Certification VR-101 for gas, factory installed top tube to valve body. **CARB EVR Phase 1 Certification VR-101 for gas/E85, factory installed top tube to valve body. ***Biofuel Compatible (E-85/Biodiesel). A Franklin Fueling Systems Brand franklinfueling.com 3760 Marsh Rd. • Madison, WI 53718, USA Tel: +1 608 838 8786 • Fax: +1 608 838 6433 Tel: USA & Canada +1 800 225 9787 • Tel: UK +44 (0)1473 243300 Tel: Mex 001 800 738 7610 • Tel: FR +33 (0)1 69 21 41 41 • Tel: CH +86 10 8565 4566 FFS-0275 07-14 Overall Length 172.00 in. / 4368.8 mm 196.00 in. / 4978.4 mm 172.00 in. / 4368.8 mm 172.00 in. / 4368.8 mm 196.00 in. / 4978.4 mm 196.00 in. / 4978.4 mm 172.00 in. / 4368.8 mm 232.00 in. / 5892.8 mm 256.00 in. / 6502.4 mm 216.00 in. / 5486.0 mm 216.00 in. / 5486.0 mm 256.00 in. / 6502.4 mm 216.00 in. / 5486.0 mm 240.00 in. / 6096.0 mm 240.00 in. / 6096.0 mm 172.00 in. / 4368.8 mm 196.00 in. / 4978.4 mm 190 in / 4826 mm 214 in / 5435.6 mm N/A Rivet on Rivet on Rivet on N/A N/A N/A N/A
© Copyright 2025 ExpyDoc