Fire Damper FIRE DAMPER FD40 KAD Air Conditioning Est. P.O. Box 5389, Dubai, UAE. Tel: +971 4 806 7676 Fax: +971 4 806 7688 Email: [email protected] Web: www.kadairconditioning.com klimaoprema HR-10430 Samobor, Croatia, Gradna 78A. FIRE DAMPER - FD40 FIRE DAMPER FD40 • • • 350 Used for the isolation of duct penetrations between fire compartments. Fire dampers consist of housing, fire-resistant damper blade and release mechanism. Casing made of galvanised sheet steel, damper blade made of special insulating material, damper blade shaft and push rod made of stainless steel, plastic plain bearings made of brass, seals made of polyurethane and elastomer. FIRE PROTECTION • Fire resistance according to EN 1366-2, classified according to EN 13501-3, Declaration of performance given according to Anex III of Regulation No 305/2011 • • • Rigid wall: Flexible wall: Ceiling / floor: EI 120 (ve, i↔o)S EI 120 (ve, i↔o)S EI 120 (ho, i↔o)S DAMPER MODELS FD40-M rectangular fire damper with electric actuator. • • • • B 30 30 Options: M230 – electric actuator AC 230V M24 – electric actuator AC/DC 24V 30 120 250 H 4 2 5 3 6 30 1 2 3 4 5 6 01 fire damper housing damper blade electric actuator: Belimo B(L)F thermo-electric tripping device (72°C) smoke seal intumescent strip thermoelectric activation (72°C) with electric actuator and return spring integrated end switches fully automatic operation networking capability (MP-BUS, LonWorks, AS-i BUS) DIMENSIONS Min. dimensions B(W) x H [mm] Max. dimensions B(W) x H [mm] 200x200 1500x800 All possible combinations of width and height are available. Standard dimensions are avaliable with increments of 50mm. Design changes reserved FIRE DAMPER - FD40 INSTALLATION IN RIGID WALL Fire damper FD40 is suitable for installation in all types of rigid, flexible walls and ceilings. Installation should be performed according to the installation instructions provided by the manufacturer. Installation steps: 1. Wall opening H(B)+160mm 2. Damper fixing (damper blade should be in a closed position during installation!) 3. Fill the gap between damper and wall with mortar During installation use wooden struts to prevent deformation of casing, caused by drying gypsium plaster or mortar. 20 0 Opening in the wall: (B+160) x (H+160) 137 z> 100 s> 80 standard gypsum plaster Masterboard thickness 20mm After installation check for damper blade mobility, preform an opening and closing test. Design changes reserved 02 FIRE DAMPER - FD40 INSTALLATION IN FLEXIBLE WALL 20 0 Opening in the wall: (B+160) x (H+160) 12307 25 >1 z standard concrete mortar s≥ 80 Masterboard thickness 20mm CW metal profile gypsum plasterboards (thickness 12,5mm) mineral wool (density 50kg/m3) screw for gypsum plasterboard After installation check for damper blade mobility, preform an opening and closing test. INSTALLATION IN CEILING Opening in the wall: (B+160) x (H+160) 0 After installation check for damper blade mobility, preform an opening and closing test. 03 80 s> Design changes reserved 13270 z>125 20 Masterboard thickness 20mm gypsum plaster or mortar FIRE DAMPER - FD40 SELECTION DIAGRAM Symbol: v - air velocity in the duct [m/s] ∆pt - total pressure loss [Pa] LWA - sound power level [dB(A)] Total pressure loss and sound power level for B=400: 0 70 H= 0 0 8 H= The values of total pressure loss for other sizes are obtained in a manner that read value from the graph is multiplied with the correction value from the table. Value of sound power are obtained in a manner that read value is added the correction value from the table. B [mm] 200 250 300 350 400 450 500 550 600 650 700 750 800 850 900 950 10001200 12001500 ∆pt x 1,22 1,14 1,07 1,0 0,94 0,88 0,83 0,77 0,73 0,68 0,64 0,6 0,58 0,56 0,55 0,54 0,5 0,4 Lwa+ -1 -1 0 0 0 0 0 0 0 0 1 1 2 2 2 3 3 4 ORDERING KEY FD40 - 400x300 - M230 - S - G1 Damper type Damper dimensions B(W) x H [mm] Mechanism type: R - manual mechanism E230 - solenoid actuator AC230V E24 - solenoid actuator AC 24V M230 - electric actuator AC230V M24 - electric actuator AC/DC 24V Options: s - electric limit switches (indicating damper “OPEN” and “CLOSED”) z - electric limit switch (indicating damper “CLOSED”) o - electric limit switch (indicating damper “OPEN”) Grille: G1 - grid on one side G2 - grid on both sides Design changes reserved 04 FIRE DAMPER - FD40 OPERATING INSTRUCTIONS Damper is delivered in closed position. When electric actuator is connected to the power supply damper will open. When the damper reaches the end position (damper open), in which is it blocked, the electromotor will stop. Closing fire damper takes place automatically when a power failure occurs. Thermal tripping device that comes with fire damper causes power circuit break at a temperature of 72 °C (inside or outside duct). If checking is needed for proper fuctioning of fire damper, pushing the switch on the thermal tripping device will close damper. When switch on tripping device is released, the damper will open. switch for checking for proper fuctioning BLF230 BELIMO handle for manual opening Manual opening Damper can be opened without connecting to a voltage with enclosed handle turning in the direction of the arrow on electric acuator (clockwise). Damper can be locked in the desired position by fast turning back handle a quarter of a turn (counterclockwise). To unlock the electromotor, turn handle clockwise for a quarter of a turn. If the handle is released, damper will be closed by return spring. When damper is opened manually, electric actuator will not move the damper into closed position after power failure (thermoelectric fuse). FD40-R DAMPER CLOSED CLOSED 05 OPEN DAMPER OPEN CLOSED Design changes reserved OPEN FIRE DAMPER - FD40 FD40-E Fire damper is delivered in closed position. To open the damper, handle should be turned in counter-clockwise direction to “OPEN” position. It is possible to close damper with solenoid. The damper is opened manually. Manual damper activation is intended for periodic maintenance. DAMPER CLOSED CLOSED DAMPER OPEN OPEN CLOSED OPEN ELECTRICAL CARACTERISTICS AND WIRING SCHEME OF ELECTRICAL ACTUATOR BELIMO BLF24-T BF24-T BLF230-T BF230-T AC/DC 24V, 50/60Hz AC/DC 24V, 50/60Hz AC 230V, 50/60Hz AC 230V, 50/60Hz Type of Belimo actuator voltage Nominal voltage / power consumption opening 5W 7W 6W 8W holding 2,5 W 2W 3W 3W for wire sizing 7 VA 10 VA 7 VA 12,5 VA 1 mA...3 A (0.5 A), DC 5 V...AC 250 V 1 mA...6 A (3 A), DC 5 V...AC 250 V 40...75 s <140 s ~20 s ~16 s 1 mA...3 A (0,5 A), DC 1mA...6A (3A), DC 5V... 5 V...AC 250V AC 250V End switch motor Running time spring-return 40...75 s <120 s ~20 s ~16 s Ambient temperature range T 1 ~ – max. 50°C 1 2 S1 S2 S3 S4 S5 S6 + 2 S1 S2 S3 S4 S5 S6 Tf1 <5° <80° Tf2 Tf3 Tf1 Tf2 Tf3 LED negative (direct-current) or neutral (alternating current) positive (direct-current) or faze (alternating current) common micro switch closed damper normally closed micro switch closed damper normally open micro switch closed damper common micro switch open damper normally closed micro switch open damper normally open micro switch open damper temperature sensor on the outer side of the duct (ambient temperature) max. 72°C temperature sensor on the inner side of the duct (temperature in the duct) max. 72°C temperature sensor on the inner side of the duct (temperature in the duct) max. 72°C BAE72B-S Belimo BLF24-T i BF24-T supply via safety isolation transformer Design changes reserved 06 CONTACT US KAD Air Conditioning Est. P.O. Box 5389, Dubai, UAE. Tel: +971 4 806 7676 Fax: +971 4 806 7688 Email: [email protected] Web: www.kadairconditioning.com klimaoprema HR-10430 Samobor, Croatia, Gradna 78A.
© Copyright 2024 ExpyDoc