EIDIS COOLROOM REFRIGERATION SYSTEMS Drop-in, Push-in & Slide-in Packaged Coldroom Refrigeration Systems Series 4 Outstanding Quality and Reliability ty. Built in Australia to perform r in Australian conditions www.eidis.com.au Push-In Unit Company Philosophy Customer satisfaction. Constant improvement in construction and efficiency. Use of proven componentry and controls from the world’s leading manufacturers. Simplicity of design facilitating on-site service, particularly in remote locations. 1212/4 Model Special units to customer requirements. 1212/4 Model ROOF PANEL Drop-in Models ROOF PANEL ROOF PANEL P ROOF PANEL P 2012/4 Model Features Push-in Global Model Slide-in Models P WALL PANEL W WALL PANEL Model • Both heat exchange coils use rifle bore tubing. • Accurate metal pressing by C.N.C. Turret. • Compact construction minimising freight cost. • Bench tested before packaging. • Each system has an installation Both heat exchange coils useinstruction rifle bore tubing. sheet, a unit to coldroom sealing strip, Accurate metal pressing by C.N.C. Turret. electronic componentry useage instructions where required and a drawing showing cut out Compact and construction minimising freight cost. dimensions positioning. • Constant construction and Bench improvement tested before in packaging. efficiency. systemcomponentry has an installation instruction • UseEach of proven and controls from sheet, a unit to coldroom sealing strip, the world’s leading manufacturers. electronic componentry useage instructions • Simplicity of design facilitating on-site service, where required and a drawing showing cut out particularly in remote locations. dimensions and positioning. • Special units to customer requirements. WALL PANEL W P WALL PANEL Features 1212/4 Drop-in, Slide-in & Push-In Coldroom Refrigeration Systems Series 4 (NOMINAL) WATTS (NOMINAL) 1300 (NOMINAL) EVAP. KTD (NOMINAL) 5 68/466/4 1300 1940 6.8 5 88/468/4 1940 2280 7 6.8 88/4 1212/4 2280 3220 6 1212/4 2012/4DIE 3220 4200 66/4PI Global 66/4PI Global 1300 1300 68/4PI Global 68/4PI Global 1940 1940 88/4PI Global 88/4PI Global 2280 2280 66/4 COMPRESSOR COMPRESSOR HP REFRIGERANT (NOMINAL) HP REFRIGERANT 1(NOMINAL) /2 R404A POWER INPUT NOMINAL POWER INPUT EVAPORATOR FAN NOMINAL DIAMETER WATTS AMPS EVAPORATOR FAN DIAMETER WATTS AMPS 300mm 73 3.8 1/2 R404A R404A 300mm 300mm 73 73 4.1 3.8 7 11/4 /8 R404A R404A 300mm 300mm 73 73 6.0 4.1 7 1 11/21 /4 R404A R404A 300mm 350mm 130 73 10.26.0 5 6 1 21/41 /2 R404A R404A 350mm 2 x 300mm 2 x 80130 10.2 13.3 FLA 5 5 1/2 R404A R404A 300mm 300mm 73 73 3.8 3.8 7/8 R404A R404A 300mm 300mm 73 73 4.1 4.1 R404A R404A 300mm 300mm 73 73 6.0 6.0 6.8 6.8 7 7 7/8 1/2 7/8 1 11/41 /4 Standard power requirement 220/240 volt 50/HZ. • Standard power requirement 220/240 volt 50/HZ. Easily installed. • Easily installed. No skilled personnel needed on site. • No skilled personnel needed on site. • Just place in a prepared hole.hole. Just place in a prepared • Units are provided with electrical cable and 3 pin plug. Units are provided with electrical cable and 3 pin plug. • Reliable, safe operation. Reliable, safe operation. • Controls of conventional design, unaffected by voltage spikes.of conventional design, unaffected by Controls voltage spikes.models have cross ambient • Drop-In & Slide-In temperature 2°Ccross to 3°Cambient Drop-In controls & Slide-Infactory modelssethave roomtemperature temperature.controls PI Globalfactory modelset electonic 2°C to 3°C controls, LED display. Adjustable user. roomwith temperature. PI Global modelby electonic LEDwith display. Adjustable user. • Dual controls, pressure with control manual or auto by reset on high cut to protect against airflow on Dualout pressure control with condenser manual or auto reset restriction on out Drop-in and Slide-in high cut to protect against Models. condenser airflow • Optional electronic digital controls can Models. be supplied on restriction on Drop-in and Slide-in unit if indicated at time of ordering. Optional electronic digital controls can be supplied • Vibration freeif balanced external fans. on unit indicated at time ofrotor ordering. • Baseplate powder coated. Vibration free balanced external rotor fans. • Moulded white a.b.s. insulated inner panel. Baseplate powder coated. • Evaporator casing, white powder coated aluminium. Moulded white a.b.s. insulated inner panel. Evaporator casing, white powder coated aluminium. Drop-in Models Models ROOF PANEL P ROOF PANEL P Slide-in Models Models P PANEL W WALL MODELS REFRIGERATION CAPACITY REFRIGERATION WATTS CAPACITY EVAP. KTD W WALL P PANEL MODELS MODEL 66/4, 68/4, 88/4 DROP-IN MODEL L 66/4, 68/4, 88/4 DROP-IN VERTICAL WALL OF COLDROOM VERTICAL WALL OF COLDROOM Minimum 150mm (6 inches) from back wall. Minimum 150mm (6 inches) from back wal 350mm 350mm Packaged Dimensions and Weights CUT OUT HOLE SIZES l. Rubber Seal placed Rubberaround Seal the top around surface placed surface ofthe thetophole. of the hole. AIRFLOW AIRFLOW WEIGHT 66/4 720 x 460 x 99 52kg 68/4 720 x 460 x 1060 61kg 88/4 720 x 460 x 1060 67kg 1212/4 970 x 680 x 1120 120kg 2012/4 1440 x 920 x 1370 180kg Slide-In Units DROP-IN UNIT POSITION WITH FANUNIT AT THE FRONT DROP-IN POSITION INSIDE THE WITH FAN ATCOLDROOM. THE FRONT INSIDE THE COLDROOM. PLAN VIEW OF COLDROOM PLAN VIEW OF COLDROOM MODEL 66/4SI, 68/4SI, 88/4SI MODEL 66/4PI, 68/4PI, 88/4PI GLOBAL PUSH-IN SYSTEM MODEL 66/4SI, 68/4SI, 88/4SI CEILING OF COLDROOM MODEL 66/4PI, 68/4PI, 88/4PI GLOBAL PUSH-IN SYSTEM CEILING HOLEOF IN COLDROOM WALL OF MODEL DIMENSIONS WEIGHT 66/4SI 1120 x 700 x 670 73kg 68/4SI 1120 x 700 x 670 82kg 88/4SI 1120 x 700 x 670 86kg 0 x 670 120kg 1212/4SI 1420 x 1000 400mm400mm DIMENSIONS 635mm HOLE IN ROOF OF COLDROOM HOLE IN WALL OF 635x350mm COLDROOM 635x350mm Drop-In Units MODEL 635mm COLDROOM 625x400mm HOLE IN WALL OF 625mm COLDROOM 625x400mm 625mm POSITION UNIT WITH FAN AT THE FRONT POSITION WITH INSIDE THE UNIT COLDROOM. FAN AT THE FRONT INSIDE THE COLDROOM. SIDE VIEW OF COLDROOM Rubber Seal placed around the front edge Rubber Seal of the hole. placed around the top surface of the hole. SIDE VIEW OF COLDROOM MODEL 1212/4 DROP-IN SYSTEM Push-In Global Units VERTICAL WALL OF COLDROOM Minimum 300mm (12 inches) from back wall. MODEL 1212/4 D ROP-IN SYSTEM WEIGHT 66/4PI 920 x 780 x 890 71kg 68/4PI 920 x 780 x 890 73kg 88/4PI 920 x 780 x 890 73kg VERTICAL800mm WALL OF COLDROOM 500mm DIMENSIONS 500mm MODEL HOLE IN ROOF OF COLDROOM Rubber Seal l. placed around the top surface of the hole. Minimum 300mm (12 inches) from back wal 800x500mm 800mm HOLE IN WALL OF COLDROOM 800x500mm Rubber Seal placed around the top surface of the hol e. AIRFLOW DROP-IN UNIT POSITION AIRFLOW WITH FAN AT THE FRONT INSIDE THE COLDROOM. DROP-IN UNIT POSITION WITH FAN AT THE FRONT INSIDE THE COLDROOM. PLAN VIEW OF COLDROOM MODEL 2012/4 DROP-IN SYSTEM PLAN VIEW OF COLDROOM VERTICAL WALL OF COLDROOM Minimum 300mm (12 inches) from back wall. RATHMINES HOLDINGS PTY LTD T/AS ABN 91 009 339 959 Factory: 10 Hyne Road, South Guildford, WA 6055 Australia 1235mm 510mm Eidis Refrigeration Systems HOLE IN ROOF OF COLDROOM 1235x510mm Rubber Seal placed around the top surface of the hole. AIRFLOW Correspondence: PO Box 35, Guildford Western Australia 6935 Telephone: +61 (08) 9478 3293 Facsimile: +61 (08) 9277 5785 Web Site: www.eidis.com.au Email: [email protected] DROP-IN UNIT POSITION WITH FAN AT THE FRONT INSIDE THE COLDROOM. PLAN VIEW OF COLDROOM THE MANUFACTURER RESERVES THE RIGHT TO CHANGE SPECIFICATION AS NECESSARY WITHOUT NOTICE.
© Copyright 2024 ExpyDoc