R410A Refrigerant PH95 Rooftop Packaged PERFORMANCE DATA INDOOR COIL ENTERING AIR TEMP 0c DB ℃ 21 23 25 27 29 31 WB ℃ 17 18 19 20 17 18 19 20 21 17 18 19 20 21 17 18 19 20 21 17 18 19 20 21 17 18 19 20 21 OUTDOOR COIL ENTERING TEMPERATURE 0C 3300℃ Tot. Cap Sens.Cap KW KW 95.2 98.6 101.4 103.5 95.5 98.7 101.4 103.8 106 95.8 98.9 101.4 103.7 106.3 96.5 99.6 101.4 104.3 107.1 97.8 100 101.6 104.3 107.2 100.3 102.2 105.8 107 109.4 68.6 62.7 56.5 50.2 74.5 68.6 62.4 56.2 49.8 80.4 74.5 68.3 61.9 55.6 85.7 80.4 74.1 67.8 61.5 85.7 81.2 80 73.7 67.4 89.7 88.2 87.8 81.9 79.3 35℃ LWB ℃ 10.9 11.8 12.9 14.1 10.9 11.9 12.9 14 15.1 10.8 11.8 12.9 14 15 10.7 12.2 12.9 14.1 15.4 10.6 12.1 12.9 14 15.3 10.4 11.9 12.8 14 15.1 Tot. Cap Sens.Cap KW KW 89.6 93 95.8 97.9 89.9 93.1 95.8 98.2 100.4 90.2 93.3 95.8 98.1 100.7 90.9 94 95.8 98.7 101.5 92.2 94.4 96 98.7 101.6 94.7 96.6 100.2 101.4 103.8 66.8 60.9 54.7 48.4 72.7 66.8 60.6 54.4 48 78.6 72.7 66.5 60.1 53.8 83.9 78.6 72.3 66 59.7 83.9 79.4 78.2 71.9 65.6 87.9 86.4 86 80.1 77.5 40℃ LWB ℃ 11.3 12.2 13.3 14.5 11.3 12.3 13.3 14.4 15.5 11.2 12.2 13.3 14.4 15.4 11.1 12.6 13.3 14.5 15.8 11 12.5 13.3 14.4 15.7 10.8 12.3 13.2 14.4 15.5 Tot. Cap Sens.Cap KW KW 85.3 88.7 91.5 93.6 85.6 88.8 91.5 93.9 96.1 85.9 89 91.5 93.8 96.4 86.6 89.7 91.5 94.4 97.2 87.9 90.1 91.7 94.4 97.3 90.4 92.3 95.9 97.1 99.5 64.9 59 52.8 46.5 70.8 64.9 58.7 52.5 46.1 76.7 70.8 64.6 58.2 51.9 82 76.7 70.4 64.1 57.8 82 77.5 76.3 70 63.7 86 84.5 84.1 78.2 75.6 45℃ LWB ℃ 11.3 12.2 13.3 14.5 11.3 12.3 13.3 14.4 15.5 11.2 12.2 13.3 14.4 15.4 11.1 12.6 13.3 14.5 15.8 11 12.5 13.3 14.4 15.7 10.8 12.3 13.2 14.4 15.5 Tot. Cap Sens.Cap KW KW 82 85.4 88.2 90.3 82.3 85.5 88.2 90.6 92.8 82.6 85.7 88.2 90.5 93.1 83.3 86.4 88.2 91.1 93.9 84.6 86.8 88.4 91.1 94 87.1 89 92.6 93.8 96.2 63.1 57.2 51 44.7 69 63.1 56.9 50.7 44.3 74.9 69 62.8 56.4 50.1 80.2 74.9 68.6 62.3 56 80.2 75.7 74.5 68.2 61.9 84.2 82.7 82.3 76.4 73.8 LWB ℃ 11.8 12.7 13.8 15 11.8 12.8 13.8 14.9 16 11.7 12.7 13.8 14.9 15.9 11.6 13.1 13.8 15 16.3 11.5 13 13.8 14.9 16.2 11.3 12.8 13.7 14.9 16 R410A Refrigerant – PH95 DUNNAIR Technical Specification PH95 Rooftop Packaged Model Total Cooling Capacity (kW)* 95.8 Number of Compressors Sensible Cooling Capacity (kW)* 72.3 Power Requirements (Volt /Phase) 415 / 3 Heating Capacity (kW) ** 96.2 Normal Max. Current (Amps /Phase) 74.4 Nominal Evaporator Air Flow (l/s) 5200 Power Input (kW) 34.2 *Entering air @ 27/19 ℃ and ambient 35℃ ** Entering air @ 21 ℃ DB and 7℃ ambient Cooling Performance Correction Capacity 2 Evaporator Coil % Rated Air Quantity - Nominal 4300 l/s Type Copper Tube / Aluminium Fins 80 90 100 110 120 Face Area (m2) 1.98 Total Cooling 0.95 0.98 1.00 1.02 1.04 Air Quantity (l/s) 5200 Sensible Cooling 0.89 0.95 1.00 1.05 1.09 Evaporator Fan Heating Performance Data Heating Capacity (kW) Number of Fans 1 Type Outdoor Coil Entering DB temperature ℃ 0 4 8 12 18 49.1 54.2 62.8 69.0 83.0 Centrifugal Drive Belt Motor Voltage /Phase /Frequency 415 / 3 / 50 Motor Power (kW) 5.5 Maximum Fan Speed (rpm) 679 Heating Performance Correction % Rated Air Quantity Multiplier 80 0.93 Return Air Temp. ℃ Approx. Defrost Factor 1.05 Outdoor Air Temp. ℃ 15 0 0.80 90 0.97 18 1.03 2 0.78 100 1.00 21 1.00 4-6 0.75 110 1.03 24 0.97 7 0.87 120 1.05 27 0.95 8 1.00 Multiplier Electrical Power Requirements 3 phase / 415V / 50Hz Normal Max. Current (Amps /Phase) 74.4 Condenser Coil Type Copper Tube / Aluminium Fins Face Area (m2) Compressor Number Per Unit 2 x 1.625 2 Type Scroll RPM (Nom) 2900 Normal Max. Current (amps /phase) 2 x36 Locked Rotor Current (amps /phase) 2 x160 Displacement (m3 /h) 2 x29.6 Condenser Fan Number of Fans Electrical Controls and Safeties High Pressure Switch (Setting kPa) 4200 Defrost Low Pressure Switch (Setting kPa) 600 Initiation Temperature (℃) -2 4 Type Axial Drive Direct Motor Watts /rpm 4 x550 / 950 Motor Voltage /Phase /Frequency 415 / 3 / 50 Refrigeration System Indoor Fan Overload Internal Termination Temperature (℃) 18 Refrigerant Type R410A Outdoor Fan Overload Internal Min. Period Between De-Ice (min) 30 Charge (kg) 2 x 11.2 Compressor Delay Timer 300 sec Max De-Ice Period (min) 10 Service Connections Rotor Lock Valves Expansion Control - In / Outdoor Unit TX Valve Standard Features Auto reset high pressure and auto reset low pressure cutouts Thermal overload protection on all motors Suction line accumulator Compressor crankcase heater Automatic de-ice system Limit start timer (anti short cycling) Thermally insulated indoor unit DUNNAIR (Aust) Pty Ltd supports a policy of continuous improvement. Therefore specifications and designs are subject to change without prior notice. Released Feb 2014 V3.1 Page 2 DUNNAIR R410A Refrigerant – PH95 DUNNAIR (Aust) Pty Ltd supports a policy of continuous improvement. Therefore specifications and designs are subject to change without prior notice. Released Feb 2014 V3.1 Page 3 DUNNAIR R410A Refrigerant – PH95 DUNNAIR (Aust) Pty Ltd supports a policy of continuous improvement. Therefore specifications and designs are subject to change without prior notice. Released Feb 2014 V3.1 Page 4 DUNNAIR R410A Refrigerant – PH95 DUNNAIR (Aust) Pty Ltd supports a policy of continuous improvement. Therefore specifications and designs are subject to change without prior notice. Released Feb 2014 V3.1 Page 5 DUNNAIR R410A Refrigerant – PH95 DUNNAIR (Aust) Pty Ltd supports a policy of continuous improvement. Therefore specifications and designs are subject to change without prior notice. Released Feb 2014 V3.1 Page 6
© Copyright 2024 ExpyDoc