TCM 230K MJS

TCM-230K Coriolis Flow Meter
SPECIFICATIONS:
Mass Flow Rate
Volumetric
Flow Rate
Nominal Meter
Size
Pressure
Rating
8433 Lbs/Min (230,000 Kg/Hr)
1012 Gpm, 230,000 Lph,
34,700 Bbl/Day
3-4"
1450 psig (100 bar)
ACCURACY:
Basic Accuracy = ±0.10%of flow reading
Zero Stability = 0.01% of full scale, 0.84 lbs/min (23.0 kg/hr)
Basic accuracy ±0.10% of flow rate + zero stability * 100% flow rate.
(Stated accuracy combines the effects of repeatability, linearity, and hysteresis.)
DENSITY:
Density Accuracy: Liquids: ±1.0 kg/m3, ±0.001 g/cm 3
Density Repeatability: ±0.5 kg/m3, ±0.0005 g/cm3
Density Range: Up to 2,500 kg/m3, 2.5 g/cm3
TEMPERATURE:
Media Temperature Range: -40 to 212°F (-40 to 100°C)
Temperature Accuracy: ±1.0°C, ±0.5%
of reading, repeatability ±0.1%.
PRESSURE:
Process Pressure Effect*:
Mass Flow Accuracy:
±0.001% of rate per PSI**
Density Accuracy:
±0.00003 g/cm3 per PSI**
MATERIALS OF CONSTRUCTION:
Wetted Parts:
316L SS seamless tubing
Case: 304 SS
Casting: 316 SS Grade CF3M
Brazing Alloy: BNi-2
Proud Distributor of TRICOR Coriolis Technology:
421 N 10th St • La Porte, TX 77571
Off (281) 842-7600• Fax (281) 842-7601
www.mjsusa.com • [email protected]