Circuit Breaker Enclosures Enclosures

Circuit Breaker
Enclosures
Enclosures
Class 610
•
•
•
•
•
Table 7.137:
Circuit Breaker Enclosures
Circuit Breaker
Cat. No. Prefix
FAL, FHL, FCL
FA100S
QBL, QDL, QGL, QJL
HDL, HGL, HJL, HLL
JDL, JGL, JJL, JLL
HDL
JDL
LAL, LHL, Q4L
LAL
MGL, MJL, PGL, PJL,
PKL, PLL
PGL, PJL, PKL, PLL
Enclosure
Rating
Poles
Cat. No.
$ Price
7
MINIATURE AND MOLDED CASE
CIRCUIT BREAKERS
FA100DS
FAL, FHL, FCL
HDL, HGL, HJL, HLL
JDL, JGL, JJL, JLL
KILq, KCL
LAL, LHL, Q4L
LEL, LXL, LXIL
LCL, LIL
MGL, MJL, PGL, PJL,
PKL, PLL
PGL, PJL, PKL, PLLl
15–100 A
100–200 A
100–225 A
15–150 A
150–250 A
15–100 A
150–250 A
125–400 A
125–400 A
1, 2, 3
2
2, 3
2, 3
2, 3
3
3
2, 3
3
300–800 A
2, 3
—
250–1200 A
2, 3
—
15–100 A
15–150 A
150–250 A
110–250 A
125–400 A
100–600 A
300–600 A
1, 2, 3
2, 3
2, 3
2, 3
2, 3
3
2, 3
300–800
2, 3
Cat. No.
NEMA 1 Flush
FA100F
189.00
—
—
Q23225NFb
218.00
$ Price
NEMA 1 Surface
FA100S
189.00
Q22200NSb
176.00
Q23225NSb
218.00
Cat. No.
NEMA 3Ra
FA100RB
Q22200NRBb
Q23225NRBb
$ Price
500.00
380.00
417.00
J250Fcde
285.00
J250Scde
285.00
J250Rcde
840.00
—
—
LA400F
—
—
—
356.00
—
HD100Sfgcei
JD250Sigfce
LA400S
LA400LSgiw
285.00
285.00
356.00
356.00
—
—
LA400R
—
—
—
1655.00
—
—
M800Sjk
783.00
M800Rjm
2159.00
—
P1200Sk
NEMA 4, 4X, 5, 3, 3R Stainless
Steel (Hubs—See page 3-9)
FA100RB
ZZZVFKQHLGHUHOHFWULFXV
Circuit breaker enclosures are UL Listed, CSA Certified and are suitable for use as service equipment except as footnoted.
The short circuit rating of an enclosed circuit breaker is equal to the rating of the circuit breaker installed, except as footnoted.
Circuit breakers are ordered and shipped separately for field installation.
For enclosure accessories and dimensions refer to page 7-58.
See Supplemental Digest page 3-35 for NEMA 7 and 9 enclosures for FAL circuit breakers.
1260.00
P1200Rm
NEMA 12/3R, 12K (Hubs—See page 3-9)
With Knockouts (NEMA 12K)
351.00
2790.00
Without Knockoutsn
(NEMA 12/3R, 5)
FA100AWK
335.00
FA100DS
1431.00
FA100A
J250DScde
3405.00
—
—
J250AWKcde
582.00
IK250DS
LA400DS
—
—
5238.00
5673.00
—
—
—
—
—
—
—
—
—
—
IK250AWK
LA400AWK
LX600AWK
LX600AWK
878.00
903.00
3728.00
3728.00
M800DSo
10125.00
—
—
M800AWKo
2459.00
P1200AWKo
5700.00
—
—
—
—
Nema 7r Cast Aluminum
Nema 9u Cast Aluminum
JDL, JGLstv
150–250 A
2, 3
J225X
4083.00
J225Y
2834.00
a
Enclosures with NRB or RB suffix have provisions for 3/4 in. through 2-1/2 in. bolt-on hubs in top endwall. Enclosures with R suffix have blank endwalls
and require field cut opening. For details and hub catalog numbers see page 3-9.
b
Not CSA Certified.
c
Accepts standard rated 80% breakers. Not rated at 100%.
d
Maximum short circuit rating is 25 kAIR at 600 Vac, 65 kAIR at 480 Vac, 125 kAIR at 240 Vac.
e
Earth Leakage Module and Ground Fault Module are not compatible with these enclosures.
f
Maximum short circuit rating is 25 kAIR, 240 Vac.
g
Order service ground kit PKOGTA2 if required.
h
Maximum short circuit rating is 18 kAIR, 480 Vac and 240 Vac.
i
Copper wire only.
j
When using a CT in the M800S and R enclosure the unit will no longer accommodate a 200% neutral solution.
k
CE certified per IEC60439-1, IP20D, PE type TN-C or TN-S
l
Accepts MGL or MJL standard rated (80%) breakers. Accepts PGL, PJL or PLL circuit breakers rated 80% (1200 A maximum) or
100% rated breakers, (800A maximum).
m
CE certified per IEC60439-1, IP24D, PE type TN-C or TN-S
n
Suitable for rainproof NEMA 3R application by removing drain screw from bottom endwall.
o
CE certified per IEC60439-1, IP56, PE type TN-C or TN-S
p
LEL 100% rated circuit breaker except for 600 A sensor.
q
Short circuit rating is 100 k AIR at 480 Vac maximum.
r
NEMA 7—Indoor Hazardous Locations—Division 1 and 2, Class I, Groups C and D; Class II, Groups E, F,and G; Class III.
s
80% rated circuit breakers only; SCCR 65 kA @ 240 Vac, 25 kA @ 480 Vac, 18 kA @ 600 Vac.
t
Not UL Listed due to wire bending space.
u
NEMA 9—Indoor Hazardous Locations—Division 1 and 2, Class II, Groups E, F,and G; Class III.
v
Has a tapped 2-1/2 in. conduit opening on top and bottom end wall
w
Short circuit current rating is 30 k AIR at 480 Vac.
600–1200
2, 3
316 Grade Stainless Steel Circuit Breaker Enclosures—NEMA 3, 3R, 4X, 5 and 12
Type 316 stainless steel circuit breaker enclosures offer superior corrosion resistance to a wider range of chemicals
than Type 304 stainless steel enclosures. Type 316 better resists chloride and is often used in marine, waste treatment
and transportation applications. Use watertight hubs from Section 3 page 10 of Digest 176. For other accessories
reference Table 7.142 and Table 7.143. For dimensional information, reference Table 7.144.
Table 7.138:
316 Grade Stainless Steel CIrcuit Breaker Enclosures
Circuit Breakery
Cat. No. Prefix...Suffix
HDL, HGL, HJL, HLL
JDL, JGL, JJL, JLL
MGL, MJL, PGL, PJL
PKL, PLL
Table 7.139:
NEMA 3, 3R, 4X, 5 and 12
Ampere Rating
15–150 A
150–250 A
Poles
2, 3
2, 3
Enclosure Cat. No.
$ Price
J250SS
4698.00
300–800 A
2, 3
M800SS
13972.00
DC CIrcuit Breaker Enclosures for MA and MH DC-Rated Circuit Breakers
Circuit Breakery
x
y
NEMA 1 Surface Enclosurex
Cat. No. Prefix...Suffix
Ampere Rating
MAL, MHL
125–1000 A
UL Listed Only
Use 500 Vdc or 250 Vdc rated circuit breakers only.
Poles
2, 3
Enclosure Cat. No.
MA1200S
$ Price
1355.00
Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Page 7-58
Dimensions. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Page 7-58
7-56
DE1
DE2A
Discount
Schedule