Circuit Breaker Enclosures Enclosures Class 610 • • • • • Table 7.137: Circuit Breaker Enclosures Circuit Breaker Cat. No. Prefix FAL, FHL, FCL FA100S QBL, QDL, QGL, QJL HDL, HGL, HJL, HLL JDL, JGL, JJL, JLL HDL JDL LAL, LHL, Q4L LAL MGL, MJL, PGL, PJL, PKL, PLL PGL, PJL, PKL, PLL Enclosure Rating Poles Cat. No. $ Price 7 MINIATURE AND MOLDED CASE CIRCUIT BREAKERS FA100DS FAL, FHL, FCL HDL, HGL, HJL, HLL JDL, JGL, JJL, JLL KILq, KCL LAL, LHL, Q4L LEL, LXL, LXIL LCL, LIL MGL, MJL, PGL, PJL, PKL, PLL PGL, PJL, PKL, PLLl 15–100 A 100–200 A 100–225 A 15–150 A 150–250 A 15–100 A 150–250 A 125–400 A 125–400 A 1, 2, 3 2 2, 3 2, 3 2, 3 3 3 2, 3 3 300–800 A 2, 3 — 250–1200 A 2, 3 — 15–100 A 15–150 A 150–250 A 110–250 A 125–400 A 100–600 A 300–600 A 1, 2, 3 2, 3 2, 3 2, 3 2, 3 3 2, 3 300–800 2, 3 Cat. No. NEMA 1 Flush FA100F 189.00 — — Q23225NFb 218.00 $ Price NEMA 1 Surface FA100S 189.00 Q22200NSb 176.00 Q23225NSb 218.00 Cat. No. NEMA 3Ra FA100RB Q22200NRBb Q23225NRBb $ Price 500.00 380.00 417.00 J250Fcde 285.00 J250Scde 285.00 J250Rcde 840.00 — — LA400F — — — 356.00 — HD100Sfgcei JD250Sigfce LA400S LA400LSgiw 285.00 285.00 356.00 356.00 — — LA400R — — — 1655.00 — — M800Sjk 783.00 M800Rjm 2159.00 — P1200Sk NEMA 4, 4X, 5, 3, 3R Stainless Steel (Hubs—See page 3-9) FA100RB ZZZVFKQHLGHUHOHFWULFXV Circuit breaker enclosures are UL Listed, CSA Certified and are suitable for use as service equipment except as footnoted. The short circuit rating of an enclosed circuit breaker is equal to the rating of the circuit breaker installed, except as footnoted. Circuit breakers are ordered and shipped separately for field installation. For enclosure accessories and dimensions refer to page 7-58. See Supplemental Digest page 3-35 for NEMA 7 and 9 enclosures for FAL circuit breakers. 1260.00 P1200Rm NEMA 12/3R, 12K (Hubs—See page 3-9) With Knockouts (NEMA 12K) 351.00 2790.00 Without Knockoutsn (NEMA 12/3R, 5) FA100AWK 335.00 FA100DS 1431.00 FA100A J250DScde 3405.00 — — J250AWKcde 582.00 IK250DS LA400DS — — 5238.00 5673.00 — — — — — — — — — — IK250AWK LA400AWK LX600AWK LX600AWK 878.00 903.00 3728.00 3728.00 M800DSo 10125.00 — — M800AWKo 2459.00 P1200AWKo 5700.00 — — — — Nema 7r Cast Aluminum Nema 9u Cast Aluminum JDL, JGLstv 150–250 A 2, 3 J225X 4083.00 J225Y 2834.00 a Enclosures with NRB or RB suffix have provisions for 3/4 in. through 2-1/2 in. bolt-on hubs in top endwall. Enclosures with R suffix have blank endwalls and require field cut opening. For details and hub catalog numbers see page 3-9. b Not CSA Certified. c Accepts standard rated 80% breakers. Not rated at 100%. d Maximum short circuit rating is 25 kAIR at 600 Vac, 65 kAIR at 480 Vac, 125 kAIR at 240 Vac. e Earth Leakage Module and Ground Fault Module are not compatible with these enclosures. f Maximum short circuit rating is 25 kAIR, 240 Vac. g Order service ground kit PKOGTA2 if required. h Maximum short circuit rating is 18 kAIR, 480 Vac and 240 Vac. i Copper wire only. j When using a CT in the M800S and R enclosure the unit will no longer accommodate a 200% neutral solution. k CE certified per IEC60439-1, IP20D, PE type TN-C or TN-S l Accepts MGL or MJL standard rated (80%) breakers. Accepts PGL, PJL or PLL circuit breakers rated 80% (1200 A maximum) or 100% rated breakers, (800A maximum). m CE certified per IEC60439-1, IP24D, PE type TN-C or TN-S n Suitable for rainproof NEMA 3R application by removing drain screw from bottom endwall. o CE certified per IEC60439-1, IP56, PE type TN-C or TN-S p LEL 100% rated circuit breaker except for 600 A sensor. q Short circuit rating is 100 k AIR at 480 Vac maximum. r NEMA 7—Indoor Hazardous Locations—Division 1 and 2, Class I, Groups C and D; Class II, Groups E, F,and G; Class III. s 80% rated circuit breakers only; SCCR 65 kA @ 240 Vac, 25 kA @ 480 Vac, 18 kA @ 600 Vac. t Not UL Listed due to wire bending space. u NEMA 9—Indoor Hazardous Locations—Division 1 and 2, Class II, Groups E, F,and G; Class III. v Has a tapped 2-1/2 in. conduit opening on top and bottom end wall w Short circuit current rating is 30 k AIR at 480 Vac. 600–1200 2, 3 316 Grade Stainless Steel Circuit Breaker Enclosures—NEMA 3, 3R, 4X, 5 and 12 Type 316 stainless steel circuit breaker enclosures offer superior corrosion resistance to a wider range of chemicals than Type 304 stainless steel enclosures. Type 316 better resists chloride and is often used in marine, waste treatment and transportation applications. Use watertight hubs from Section 3 page 10 of Digest 176. For other accessories reference Table 7.142 and Table 7.143. For dimensional information, reference Table 7.144. Table 7.138: 316 Grade Stainless Steel CIrcuit Breaker Enclosures Circuit Breakery Cat. No. Prefix...Suffix HDL, HGL, HJL, HLL JDL, JGL, JJL, JLL MGL, MJL, PGL, PJL PKL, PLL Table 7.139: NEMA 3, 3R, 4X, 5 and 12 Ampere Rating 15–150 A 150–250 A Poles 2, 3 2, 3 Enclosure Cat. No. $ Price J250SS 4698.00 300–800 A 2, 3 M800SS 13972.00 DC CIrcuit Breaker Enclosures for MA and MH DC-Rated Circuit Breakers Circuit Breakery x y NEMA 1 Surface Enclosurex Cat. No. Prefix...Suffix Ampere Rating MAL, MHL 125–1000 A UL Listed Only Use 500 Vdc or 250 Vdc rated circuit breakers only. Poles 2, 3 Enclosure Cat. No. MA1200S $ Price 1355.00 Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Page 7-58 Dimensions. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Page 7-58 7-56 DE1 DE2A Discount Schedule © 2012 Schneider Electric All Rights Reserved
© Copyright 2025 ExpyDoc