Hilti MI/MQ Technical Guide
5.0 Installation System Hangers
5.9 Cast In
Continuous Concrete Insert Strut
Product Features
• Use with a variety of Hilti fasteners to hang threaded rod
• PV foam insert keeps wet concrete out of channel and
removes easily in one piece once concrete is cured
Material Specifications
Material and finish
ASTM A1011 (replaces A570) Grade 33 Carbon Steel
Pre-galvanized to G90
Ordering Information
Description
Qty
Item No.
Cast In Strut 1 3/8" x 12 ga x 20'
10
03448648
Cast In Strut 13/16" x 12 ga x 20'
10
03448649
Note: Allow two to three weeks for delivery.
Technical Data — Allowable Loads1, 2, 3
Nut
Thickness
Box Qty
Item No.
Allowable Tension
(Pullout) (lbs)
Allowable Shear
(Slip) (lbs)
MQM-F 1/4”
n.a.
50
00377881
755
2002
7
MQM-F 3/8”
n.a.
50
00377882
1800
5502
15
30
Description
Bolt Torque
(ft-lbs)
MQM-F 1/2”
n.a.
50
00377883
1800
5502
1/4" Spring Nut
1/4”
100
00258246
450
300
6
3/8" Spring Nut
3/8"
100
00258247
1100
800
19
1/2" Spring Nut
1/2"
100
00258248
2000
1500
50
3/8" Channel Nut
3/8”
100
00311937
1100
800
19
1/2" Channel Nut
1/2"
100
00311938
2000
1500
50
5/8" Channel Nut
1/2"
100
00311939
2000
1500
100
3/4" Channel Nut
1/2"
100
00311940
2000
1500
125
See pag
es
91 and 9
2
for addit
ional
product
informati
on.
1 MQM Wing Nuts should be used in tension applications only. Standard Channel or Spring Nuts can be used in shear and/or tension applications.
2 See technical data for the individual part for safety factor and other load data.
3 Values are for galvanized strut and MQM Wing Nuts.
Technical Data General Notes
Allowable tensile load capacity is 2000 lbs/ft based on minimum concrete
compressive strength of 3000 psi NW and a safety factor of 2.5. Applied loads
must be >2" from the end of strut. The minimum distance between the CIS strut
center line and the concrete edge is 5". The minimum cut length of strut is 16" to
achieve the allowable load. Hilti end caps item 00313377 must be used on field
cut ends. Field cuts must be located at typical locations as shown in the picture
to the right. Shorter lengths require “cast in end caps” and result in lower load
values.
Cast-In end caps
Hilti, Inc. (US) 1-800-879-8000 | www.us.hilti.com I en español 1-800-879-5000 I Hilti (Canada) Corp. 1-800-363-4458 I www.hilti.ca I MI/MQ Technical Guide 2012
129
Hilti MI/MQ Technical Guide
5.0 Installation System Hangers
Concrete Spot Insert
Product Features
• Use as a structural attachment in concrete. Knockout helps
keep interior empty during pour.
Material Specifications
Material and finish
Carbon Steel Electro-Galvanized meeting ASTM B633
SC3 Type I
Conforms with
Federal Specification WW-H-171 (Type 19) and
Manufacturers Standardization Society ANSI/
MSS-SP-58 (Type 18). Not UL or FM Listed
Installation
Install in accordance with ANSI/MSS-SP-58. Place
knockout side down on form and nail in place. After
concrete pour, knockout can be removed with a
screwdriver. Rod should be threaded through the
inset nut until it tightens against the top of the insert.
Ordering and Technical Information
Concrete Insert
Description
Max. Allowable Tensile Load (lb)1
Qty
Item No.
600
25
03442103
Qty
Item No.
Insert Nut 1/4"
100
3448644
Insert Nut 3/8"
100
3448645
Insert Nut 1/2"
100
3448646
Insert Nut 5/8"
100
3448647
Concrete Insert EG
1 Based on a safety factor of 3
Square Nut for Insert
Description
Note — Available on special order basis. Please contact Hilti for pricing and delivery. Not returnable.
130
Hilti, Inc. (US) 1-800-879-8000 | www.us.hilti.com I en español 1-800-879-5000 I Hilti (Canada) Corp. 1-800-363-4458 I www.hilti.ca I MI/MQ Technical Guide 2012