Medical Isolation Transformers polyMIT® MTT 1000/UL CSA C22.2 No. 601.1-M90 innovative versatile experienced Medical Isolation Transformers Safety for your patients Our medical isolation transformers offer state-of-the-art technology in aesthetic and functional design fulfilling all the requirements of the medical standard act IEC 60601-1 3rd Edition. Hence, they are the best solution for all modern and patient-oriented practices and clinics. According to EU Directive 93/94/EWG medical electronic systems must be designed in such a way that at no time patients, operating personnel or other persons come to harm. Our medical isolation transformers meet this requirement by a secure galvanic separation from the public power supply. Thereby, the leakage current of a connected device or multiple devices is limited to values below the limits defined in the medical standard act IEC 60601-1 3rd Edition. Given the very low stray magnetic field and fault-tolerant design, our isolation transformers are especially suitable to use near monitors. Protect your patients, equipment and yourself with our medical isolation transformers of the latest generation! The ideal solution for secure power supply of: • Medical diagnosis and analysis devices (stationary and mobile) es: t a c ifi Cert 85 134 ition O d S E I d N r 3 • E 01-1 6 0 6 C 9001 • IE O y S I EN ormit f N n I o D C f • tion o a r a l c • De -1 2601 L U • • Medical electronic devices or systems for therapy, surgery etc. • IT equipment • Video systems polyMIT® Series Isolation transformers with surge limiter for inrush current limitation Type polyMIT 350 polyMIT 700 312900-01 312900-02 312900-03 312900-04 350 700 1000 1700 Item number Nominal power output [VA] Ambiant operating temperature (ta) Output voltage primary [V AC] +/- 10% 30% up to 75% IEC Power connector in accordance with EN 60320-1/C14 115 / 230 115 / 230 Supply frequency [Hz] Current consumption [A] 115 / 230 V Power input fuse [A] 115 / 230 V 3.25 / 1.65 6.40 / 3.20 4.0 / 2.0 8.0 / 4.0 230 9.10 / 4.55 7.65 10.0 / 6.3 10 yes Inrush current limitation Surge limiter NTC Overtemperature protection Self-resetting temperature switch 6 x IEC 60320 6 x IEC 60320 Output voltage secondary [V AC] Output current [A] 115 / 230 50/60 Power switch input (primary side) Device output (secondary) polyMIT 1700 + 10° C up to + 40° C Relative humidity Power input polyMIT 1000 8 x IEC 60320 8 x IEC 60320 230 1.53 3.05 4.35 7.39 Operation LED display green Touch leakage current < 100 μA under normal conditions, < 500 μA single fault condition Isolation, protective earth conductor resistance > 2 M Ohm / < 0,1 Ohm Test voltage PRI - SEC [V AC] 4400 Test voltage PRI/SEC-Chassis [V AC] 1700 Electric safety class Class 1 equipment, protective earthing IP classification IP20 Certification institution TÜV Certification in accordance with IEC 60601-1:2005 3rd Edition / EN 60601-1-2 Medical equipment classification according to German Medical Device Act (MPG) Class 1 device Potential equalisation Equipotential connector according to DIN 42801 Case, surface Dimensions [mm] (W x H x D) Weight approximately [kg] Metal housing in RAL 7035 170x105x280 190x105x300 6.5 9.5 230x105x330 260x105x350 13.5 19.0 Subject to technical modifications without notice. Scope of delivery (applies to all polyMIT models): 1 • Isolation transformer • Main power cable 3 x 1 mm², length 2.5 m, black • User manual • Retain clip (main power supply) • Replacement fuses1: - T 2.0 A H (4 pc.) - T 4.0 A H (4 pc.) Technical details of the included spare fuses for each model can be found in the user manual. polyMIT® Series Isolation transformers with electronic inrush current limitation Type Item number Nominal power output [VA] polyMIT 350e polyMIT 700e polyMIT 1000e polyMIT 1700e 312901-01 312901-02 312901-03 312901-04 350 700 1000 1700 Ambiant operating temperature (ta) + 10° C up to + 40° C Relative humidity Power input Output voltage primary [V AC] +/- 10% 30% up to 75% IEC Power connector in accordance with EN 60320-1/C14 115 / 230 115 / 230 Supply frequency [Hz] 115 / 230 230 50/60 Current consumption [A] 115 / 230 V 3.25 / 1.65 6.40 / 3.20 9.10 / 4.55 7.65 Power input fuse [A] 115 / 230 V 4.0 / 2.0 8.0 / 4.0 10.0 / 6.3 10 Power switch input (primary side) Inrush current limitation yes Electronic inrush current limitation and half-wave failure recognition Overtemperature protection Device output (secondary) Self-resetting temperature switch 6 x IEC 60320 6 x IEC 60320 1.53 3.05 Output voltage secondary [V AC] Output current [A] 8 x IEC 60320 8 x IEC 60320 230 4.35 7.39 Operation LED display green Touch leakage current < 100 μA under normal conditions, < 500 μA single fault condition Isolation, protective earth conductor resistance > 2 M Ohm / < 0,1 Ohm Test voltage PRI - SEC [V AC] 4400 Test voltage PRI/SEC-Chassis [V AC] 1700 Electric safety class Class 1 equipment, protective earthing IP classification IP20 Certification institution TÜV Certification in accordance with IEC 60601-1:2005 3rd Edition / EN 60601-1-2 Medical equipment classification according to German Medical Device Act (MPG) Class 1 device Potential equalisation Equipotential connector according to DIN 42801 Case, surface Dimensions [mm] (W x H x D) Weight approximately [kg] Metal housing in RAL 7035 170x105x280 190x105x300 6.5 9.5 230x105x330 260x105x350 13.5 19.0 Subject to technical modifications without notice. ® polyMIT® Series Accessories for the polyMIT® and polyMIT®e series Item no. 312902 312904 312903 312905 312906 505747 509876 537168 537169 537170 300327 300328 2 Item Wall mounting kit Strain relief bracket secondary2 Strain relief bracket secondary2 Connecting cable 1 metre Connecting cable 2 metres Power cable Europe, 4 metres Power cable US, 4 metres Replacement fuses T 2.0 A H (4 pc.) Replacement fuses T 4.0 A H (4 pc.) Replacement fuses T 8.0 A H (4 pc.) Replacement fuses T 6.3 A H (4 pc.) Replacement fuses T 10.0 A H (4 pc) Strain relief bracket only to use with connecting cable 312905 and 312906. suitable for polyMIT / polyMITe 350/700/1000/1700 polyMIT / polyMITe 350/700 polyMIT / polyMITe 1000/1700 polyMIT / polyMITe 350/700/1000/1700 polyMIT / polyMITe 350/700/1000/1700 polyMIT / polyMITe 350/700/1000/1700 polyMIT / polyMITe 350/700/1000/1700 polyMIT / polyMITe 350 polyMIT / polyMITe 350/700 polyMIT / polyMITe 700 polyMIT / polyMITe 1000 polyMIT / polyMITe 1000/1700 MTT 1000 with UL approval Type MTT 1000 / standing version, UL approved, with NTC Item number 312150 / 312150-01 Nominal power output [VA] 850 - 1000 Ambiant operating temperature (ta) + 10° C up to + 40° C Relative humidity 30% up to 75% Power input IEC Power connector in accordance with EN 60320-1/C14 Output voltage primary [V AC] 100 - 120 / 230 Supply frequency [Hz] 50 / 60 Current consumption [A] at 100 - 120 / 230 V 9.10 - 8.9 / 4.7 Power input fuse [A] at 100 - 120 / 230 V 10.0 / 6.3 Power switch input (primary side) yes Inrush current limitation Surge limiter NTC Overtemperature protection Self-resetting temperature switch Device output (secondary) 8 x IEC 60320 Output voltage secondary [V AC] 230 Output current [A] 4.35 Automatic circuit breaker [A] 6 Touch leakage current < 100 μA under normal conditions, < 500 μA single fault condition Isolation, protective earth conductor resistance > 2 M Ohm / < 0,1 Ohm Test voltage PRI - SEC [V AC] 4400 Test voltage PRI/SEC-Chassis [V AC] 1700 Electric safety class Class 1 equipment, protective earthing IP classification IP20 Certification institution TÜV / UL Certification in accordance with IEC 60601-1:2005 3rd Edition / IEC 60601-1-2 Applied standard for cUL UL 2601-1 (E222050) In compliance with CSA C22.2 No. 601.1-M90 Medical equipment classification according to German Medical Device Act (MPG) Class 1 device Potential equalisation Equipotential connector according to DIN 42801 Case, surface Metal housing in RAL 9002 Dimensions [mm] (W x H x D) 141 x 190 x 326 Weight approximately [kg] 14.6 +/- 10% Subject to technical modifications without notice. Accessories: Item no. Item 312150-01 MTT1000/UL without main power cable 312150-02 MTT1000/UL with US main power cable 300327 Replacement fuses T 6.3 A H (for 230 V), 4 pc. 300328 Replacement fuses T 10.0 A H (for 100 V / 120 V), 4 pc. Scope of delivery: - Isolation transformer - Main power cable (3 x 1.5 mm², length = 4 m) - User manual - Retain clip (main power supply) - Replacement fuses All benefits at a glance: • Secure galvanic separation of the patient‘s environment and public power supply • Limitation of the leakage current to values below the limits defined in the medical standard IEC 60601-1:2005 3rd Edition (certified) • Reliable power supply, also for sensitive medical electronic devices • Low stray magnetic field and fault-tolerant electric design • Compact housing in aesthetic and functional design • Wide range of products for every requirement • Optional available fastening kit for mounting in almost every location Application examples: Therapy equipment Treadmills (therapy / rehabilitation) Ultrasound ECG Tel. +49 8552 41-0 Fax +49 8552 41-275 E-Mail: [email protected] www.sedlbauer.de sed01PB003uk SEDLBAUER AG Wilhelm-Sedlbauer-Str. 2 D-94481 Grafenau - Industriegebiet Reismühle
© Copyright 2025 ExpyDoc