MXZ MULTI-ZONE SYSTEMS H2i® MXZ Outdoor units 1. SPECIFICATIONS............................................................................................................................................... H2i-MXZ-2 MXZ-2C20NAHZ............................................................................................................................................... H2i-MXZ-3 MXZ-3C24NAHZ............................................................................................................................................... H2i-MXZ-4 MXZ-3C30NAHZ............................................................................................................................................... H2i-MXZ-5 MXZ-4C36NAHZ............................................................................................................................................... H2i-MXZ-6 MXZ-5C42NAHZ............................................................................................................................................... H2i-MXZ-7 MXZ-8C48NAHZ............................................................................................................................................... H2i-MXZ-8 Branch Box........................................................................................................................................................ H2i-MXZ-9 PAC-MKA50BC PAC-MKA30BC..................................................................................................................... H2i-MXZ-9 Efficiency Ratings............................................................................................................................................ H2i-MXZ-10 1-1. Compatibility Table....................................................................................................................................H2i-MXZ-11 1-2. Cooling and Heating Capacity and Characteristics.................................................................................. H2i-MXZ-12 1-3. Standard Operation Data (Reference Data)............................................................................................ H2i-MXZ-13 1-4. Standard Capacity Diagram..................................................................................................................... H2i-MXZ-14 2. EXTERNAL DIMENSIONS................................................................................................................................ H2i-MXZ-20 MXZ-2C20NAHZ ............................................................................................................................................ H2i-MXZ-20 MXZ-3C24NAHZ MXZ-3C30NAHZ................................................................................................................ H2i-MXZ-21 MXZ-4C36NAHZ MXZ-5C42NAHZ MXZ-8C48NAHZ................................................................................... H2i-MXZ-22 Branch Box...................................................................................................................................................... H2i-MXZ-23 PAC-MKA50BC PAC-MKA30BC 4. ELECTRICAL WIRING DIAGRAMS.................................................................................................................. H2i-MXZ-24 MXZ-2C20NAHZ............................................................................................................................................. H2i-MXZ-24 MXZ-3C24NAHZ MXZ-3C30NAHZ................................................................................................................ H2i-MXZ-25 MXZ-4C36NAHZ MXZ-5C42NAHZ MXZ-8C48NAHZ................................................................................... H2i-MXZ-26 Branch Box...................................................................................................................................................... H2i-MXZ-27 PAC-MKA50BC PAC-MKA30BC 5. REFRIGERANT SYSTEM DIAGRAMS............................................................................................................. H2i-MXZ-28 MXZ-2C20NAHZ............................................................................................................................................. H2i-MXZ-28 MXZ-3C24NAHZ MXZ-3C30NAHZ................................................................................................................ H2i-MXZ-29 MXZ-4C36NAHZ MXZ-5C42NAHZ MXZ-8C48NAHZ................................................................................... H2i-MXZ-30 Piping Connection Size................................................................................................................................... H2i-MXZ-31 6. CAPACITY CORRECTION CURVE BY TEMPERATURE................................................................................ H2i-MXZ-32 7. CAPACITY CORRECTION TABLE BY TEMPERATURE.................................................................................. H2i-MXZ-33 8. CAPACITY CORRECTION CURVE BY REFRIGERANT PIPING LENGTH..................................................... H2i-MXZ-34 MXZ-4C36NAHZ MXZ-5C42NAHZ MXZ-8C48NAHZ................................................................................... H2i-MXZ-34 9. CAPACITY CORRECTION TABLE BY REFRIGERANT PIPING LENGTH...................................................... H2i-MXZ-35 10. SOUND PRESSURE LEVELS........................................................................................................................ H2i-MXZ-36 MXZ-2C20NAHZ............................................................................................................................................. H2i-MXZ-36 MXZ-3C30NAHZ............................................................................................................................................. H2i-MXZ-36 MXZ-3C24NAHZ............................................................................................................................................. H2i-MXZ-36 MXZ-4C36NAHZ............................................................................................................................................. H2i-MXZ-37 MXZ-8C48NAHZ............................................................................................................................................. H2i-MXZ-37 MXZ-5C42NAHZ............................................................................................................................................. H2i-MXZ-37 11. STANDARD OPERATION RANGE................................................................................................................. H2i-MXZ-38 MXZ-2C20NAHZ MXZ-3C24NAHZ MXZ-3C30NAHZ................................................................................... H2i-MXZ-38 12. ACCESSORIES............................................................................................................................................... H2i-MXZ-39 Due to continuing improvement, above specification may be subject to change without notice. M-Series - H2i® MXZ Outdoor Units (November 2014) © 2014 Mitsubishi Electric US, Inc. H2i-MXZ-1 1. SPECIFICATIONS • Highly energy-efficient system that features 100% heating capacity at 5º F with guaranteed capacity down to -13º F • Compact side discharge outdoor unit • Indoor unit powered from outdoor unit using A-control (MXZ-2C20/3C24/3C30NAHZ only) • Auto restart following a power outage • Wired or wireless controller • Quiet operation • Built-in base pan heater to prevent ice in drain pan • MXZ- 2C20,3C24,3C30NAHZ - M-Net adaptor kits are available as an option* • Limited warranty: five years parts and seven years compressor *Included standard in PAC-MKA30/50BC Branch Box For all MXZ H2i® Series outdoor units a minimum of two indoor units must be connected and the minimum installed capacity cannot be less than 12,000 Btu/h. Due to continuing improvement, above specification may be subject to change without notice. H2i-MXZ-2 M-Series - H2i® MXZ Outdoor Units (November 2014) © 2014 Mitsubishi Electric US, Inc. 1. SPECIFICATIONS MXZ-2C20NAHZ Item Capacity Power consumption Cooling Heating 47 Heating 17 Cooling Heating 47 Heating 17 Cooling Cooling Heating Heating *1 *1 *2 *1 *1 *2 Outdoor model Indoor type Btu/h Btu/h Btu/h W W W EER SEER HSPF IV(V) COP External finish Power supply V, phase, Hz Max. fuse size (time delay) A Min. circuit ampacity A Fan motor F.L.A Model Winding resistance Ω (at 68 ºF) Compressor R.L.A L.R.A Refrigerant control Sound level dB(A) Defrost method W in. Dimensions D in. H in. Weight lb. Remote controller Control voltage (by built-in transformer) Refrigerant piping Liquid in. Valve size Gas in. Indoor Connection method Outdoor Refrigerant charge (R410A) lb. Refrigeration oil (Model) oz. MXZ-2C20NAHZ Non-Duct (09+09) Duct (09+12) 18,000 20,000 22,000 22,000 13,700 13,700 1,334 1,819 1,612 1,748 1,450 1,588 13.5 11.0 17.0 15.0 9.8 9.5 4.00 3.69 Munsell 3.0Y 7.8/1.1 208/230, 1, 60 40 28.9 1.90 MNB33FBTMC-L U-V 0.30 V-W 0.30 W-U 0.30 20 28.8 LEV 54.0 / 58.0 Reverse cycle 37-13/32 13 41-17/64 187 Wireless type 4 Not supplied (optional parts) 1/4 A,B: 3/8 Flared Flared 8 lb. 13 oz. 37.4 (FV50S) NOTE : Test conditions are based on ARI 210/240. Unit: °F Mode Cooling Heating Indoor air condition Outdoor air condition Dry bulb Wet bulb Dry bulb Wet bulb Test *1: "A" Cooling steady state at rated compressor speed "B-2" Cooling steady state at rated compressor speed "B-1" Cooling steady state at minimum compressor speed Low ambient cooling steady state at minimum compressor speed Intermediate cooling steady state at intermediate compressor speed *1: Standard rating-heating at rated compressor speed *2: Low temperature heating at maximum compressor speed Maximum temperature heating at minimum compressor speed High temperature heating at minimum compressor speed Frost accumulation at rated compressor speed Frost accumulation at intermediate compressor speed 80 80 80 80 80 70 70 70 70 70 70 67 67 67 67 67 60 60 60 60 60 60 95 82 82 67 87 47 17 62 47 35 35 (75) (65) (65) (53.5) (69) 43 15 56.5 43 33 33 Due to continuing improvement, above specification may be subject to change without notice. M-Series - H2i® MXZ Outdoor Units (November 2014) © 2014 Mitsubishi Electric US, Inc. H2i-MXZ-3 1. SPECIFICATIONS MXZ-3C24NAHZ Item Capacity Power consumption Cooling Heating 47 Heating 17 Cooling Heating 47 Heating 17 Cooling Cooling Heating Heating *1 *1 *2 *1 *1 *2 Outdoor model Indoor type Btu/h Btu/h Btu/h W W W EER SEER HSPF IV(V) COP External finish Power supply V, phase, Hz Max. fuse size (time delay) A Min. circuit ampacity A Fan motor F.L.A Model Winding resistance Ω (at 68 ºF) Compressor R.L.A L.R.A Refrigerant control Sound level dB(A) Defrost method W in. Dimensions D in. H in. Weight lb. Remote controller Control voltage (by built-in transformer) Refrigerant piping Liquid in. Valve size Gas in. Indoor Connection method Outdoor Refrigerant charge (R410A) lb. Refrigeration oil (Model) oz. MXZ-3C24NAHZ Non-Duct (06+06+09) Duct (09+09+09) 22,000 23,600 25,000 24,600 14,000 14,000 1,630 2,360 1,725 1,871 1,622 1,635 13.5 10.0 19.0 15.5 10.0 9.0 4.25 3.80 Munsell 3.0Y 7.8/1.1 208/230, 1, 60 40 29.9 1.90 MNB33FBTMC-L U-V 0.30 V-W 0.30 W-U 0.30 20 28.8 LEV 54.0 / 58.0 Reverse cycle 37-13/32 13 41-17/64 189 Wireless type 4 Not supplied (optional parts) 1/4 A: 1/2 B,C: 3/8 Flared Flared 8 lb. 13 oz. 37.4 (FV50S) NOTE : Test conditions are based on ARI 210/240. Unit: °F Mode Cooling Heating Test *1: "A" Cooling steady state at rated compressor speed "B-2" Cooling steady state at rated compressor speed "B-1" Cooling steady state at minimum compressor speed Low ambient cooling steady state at minimum compressor speed Intermediate cooling steady state at intermediate compressor speed *1: Standard rating-heating at rated compressor speed *2: Low temperature heating at maximum compressor speed Maximum temperature heating at minimum compressor speed High temperature heating at minimum compressor speed Frost accumulation at rated compressor speed Frost accumulation at intermediate compressor speed Indoor air condition Outdoor air condition Dry bulb Wet bulb Dry bulb Wet bulb 80 80 80 80 80 70 70 70 70 70 70 67 67 67 67 67 60 60 60 60 60 60 95 82 82 67 87 47 17 62 47 35 35 (75) (65) (65) (53.5) (69) 43 15 56.5 43 33 33 Due to continuing improvement, above specification may be subject to change without notice. H2i-MXZ-4 M-Series - H2i® MXZ Outdoor Units (November 2014) © 2014 Mitsubishi Electric US, Inc. 1. SPECIFICATIONS MXZ-3C30NAHZ Item Capacity Power consumption Cooling Heating 47 Heating 17 Cooling Heating 47 Heating 17 Cooling Cooling Heating Heating *1 *1 *2 *1 *1 *2 Outdoor model Indoor type Btu/h Btu/h Btu/h W W W EER SEER HSPF IV(V) COP External finish Power supply V, phase, Hz Max. fuse size (time delay) A Min. circuit ampacity A Fan motor F.L.A Model Winding resistance Ω (at 68 ºF) Compressor R.L.A L.R.A Refrigerant control Sound level dB(A) Defrost method W in. Dimensions D in. H in. Weight lb. Remote controller Control voltage (by built-in transformer) Refrigerant piping Liquid in. Valve size Gas in. Indoor Connection method Outdoor Refrigerant charge (R410A) lb. Refrigeration oil (Model) oz. MXZ-3C30NAHZ Non-Duct (09+09+12) Duct (09+09+12) 28,400 27,400 28,600 27,600 18,000 17,000 2,272 2,661 2,096 2,187 1,991 1,993 12.5 10.3 18.0 16.0 11.0 9.8 4.00 3.70 Munsell 3.0Y 7.8/1.1 208/230, 1, 60 40 29.9 1.90 MNB33FBTMC-L U-V 0.30 V-W 0.30 W-U 0.30 20 28.8 LEV 54.0 / 58.0 Reverse cycle 37-13/32 13 41-17/64 189 Wireless type 4 Not supplied (optional parts) 1/4 A: 1/2 B,C: 3/8 Flared Flared 8 lb. 13 oz. 37.4 (FV50S) NOTE : Test conditions are based on ARI 210/240. Unit: °F Mode Cooling Heating Indoor air condition Outdoor air condition Dry bulb Wet bulb Dry bulb Wet bulb Test *1: "A" Cooling steady state at rated compressor speed "B-2" Cooling steady state at rated compressor speed "B-1" Cooling steady state at minimum compressor speed Low ambient cooling steady state at minimum compressor speed Intermediate cooling steady state at intermediate compressor speed *1: Standard rating-heating at rated compressor speed *2: Low temperature heating at maximum compressor speed Maximum temperature heating at minimum compressor speed High temperature heating at minimum compressor speed Frost accumulation at rated compressor speed Frost accumulation at intermediate compressor speed 80 80 80 80 80 70 70 70 70 70 70 67 67 67 67 67 60 60 60 60 60 60 95 82 82 67 87 47 17 62 47 35 35 (75) (65) (65) (53.5) (69) 43 15 56.5 43 33 33 Due to continuing improvement, above specification may be subject to change without notice. M-Series - H2i® MXZ Outdoor Units (November 2014) © 2014 Mitsubishi Electric US, Inc. H2i-MXZ-5 1. SPECIFICATIONS MXZ-4C36NAHZ Indoor type Rated*1 Cooling Capacity BTU/h Rated power consumption*1 W EER BTU/Wh SEER BTU/Wh Capacity Rated 47°F*1 BTU/h Capacity Max. 17°F*2 BTU/h Capacity Max. 5°F BTU/h Rated power consumption 47°F*1 W COP 47°F*1 BTU/Wh HSPF IV(V) BTU/Wh Connectable indoor units (Max.) Max. Connectable Capacity Power supply Breaker Size / Max. fuse size Min. circuit ampacity Sound level (Cool/Heat) dB External finish Refrigerant control Compressor Model Motor output kW Starting method Heat exchanger Fan (drive) × No. Fan Fan motor output kW Airflow m³/min (CFM) W in (mm) Dimensions D in (mm) (H × W × D) H in (mm) Weight lb (kg) Refrigerant Charge lb (kg) Oil/ Model oz (L) High pressure protection Protection deCompressor protection vices Fan motor protection (cool) Guaranteed operation range (heat) Total Piping length (Max.) ft (m) Farthest ft (m) Max. Height difference ft (m) Chargeless length ft (m) Liquid in (mm) Piping diameter Gas in (mm) Connection meth- Indoor side od Outdoor side Heating Standard performance OUTDOOR UNIT REFRIGERANT PIPING MXZ-4C36NAHZ Outdoor model Item Ducted Mix 36,000 36,000 2,875 3,180 12.52 11.32 17.5 15.8 45,000 45,000 45,000 45,000 45,000 45,000 3,795 4,250 3.48 3.10 10.7/8.9 10.1/8.5 4 46,000 1 Phase 208 / 230 V, 60 Hz 50 A/ 52 A 42 A 49/ 53 Munsell 3Y 7.8/ 1.1 Linear Expansion Valve Hermetic ANB33FJSMT 2.8 Inverter Plate fin coil Propeller fan × 2 0.06 + 0.06 110 (3885) 41-11/32 (1050) 13+1 (330+25) 52-11/16 (1338) 276 (125) R410A 10 lbs. 9 oz.(4.8) 73 (2.3) HP switch Compressor thermo, Overcurrent detection Overheating / Voltage protection D.B 23 to 115°F . [ D.B.−5 to 46°C ] *3 D.B. −13 to 70°F [D.B. −25 to 21°C ] 492 (150) 262 (80) 164 (50)*4 0 3/8 (9.52) 5/8 (15.88) Flared Flared Non-Ducted 36,000 2,570 14.01 19.1 45,000 45,000 45,000 3,340 3.95 11.3/9.2 *1 Rating conditions Cooling Indoor : D.B. 80°F/ W.B. 67 °F [D.B.26.7°C/ W.B. 19.4°C] Outdoor : D.B. 95°F [D.B. 35.0°C] Heating Indoor : D.B. 70°F [D.B. 21.1°C] Outdoor : D.B. 47°F/ W.B. 43°F [D.B. 8.3°C/ W.B. 6.1°C] *2 Conditions Heating Indoor : D.B. 70°F [D.B. 21.1°C] Outdoor : D.B. 17°F/ W.B. 15°F [D.B. −8.3°C/ W.B. −9.4°C] *3 D.B. 5 to 115°F [D.B. −15 to 46°C], when an optional Air Outlet Guide is installed. *4 131 ft [40 m], in case of installing outdoor unit lower than indoor unit. Note: Refer to the indoor unit's service manual for the indoor units specifications. Due to continuing improvement, above specification may be subject to change without notice. H2i-MXZ-6 M-Series - H2i® MXZ Outdoor Units (November 2014) © 2014 Mitsubishi Electric US, Inc. 1. SPECIFICATIONS MXZ-5C42NAHZ Cooling Capacity Rated power consumption*1 EER SEER Capacity Rated 47°F*1 Capacity Max. 17°F*2 Capacity Max. 5°F Rated power consumption 47°F*1 COP 47°F*1 HSPF IV(V) Connectable indoor units (Max.) Max. Connectable Capacity Power supply Breaker Size / Max. fuse size Min. circuit ampacity Sound level (Cool/Heat) External finish Refrigerant control Compressor Model Motor output Starting method Heat exchanger Fan (drive) × No. Fan motor output Fan Heating Standard performance OUTDOOR UNIT Indoor type Rated*1 Airflow Dimensions (H × W × D) Weight Refrigerant REFRIGERANT PIPING MXZ-5C42NAHZ Outdoor model Item W D H BTU/h W BTU/Wh BTU/Wh BTU/h BTU/h BTU/h W BTU/Wh BTU/Wh dB kW kW m³/min (CFM) in (mm) in (mm) in (mm) lb (kg) Charge lb (kg) Oil/ Model oz (L) High pressure protection Protection deCompressor protection vices Fan motor protection (cool) Guaranteed operation range (heat) Total Piping length (Max.) ft (m) Farthest ft (m) Max. Height difference ft (m) Chargeless length ft (m) Liquid in (mm) Piping diameter Gas in (mm) Indoor side Connection method Outdoor side 42,000 3,130 13.42 19.0 48,000 48,000 48,000 3,430 4.10 11.0/9.1 42,000 3,510 11.97 17.0 48,000 48,000 48,000 3,890 3.62 10.6/9.0 5 54,000 1 Phase 208 / 230 V, 60 Hz 50 A/ 52 A 42 A 50/ 54 Munsell 3Y 7.8/ 1.1 Linear Expansion Valve Hermetic ANB33FJSMT 3.0 Inverter Plate fin coil Propeller fan × 2 0.06 + 0.06 42,000 3,890 10.80 15.0 48,000 48,000 48,000 4,350 3.23 10.1/8.8 110 (3885) 41-11/32 (1050) 13+1 (330+25) 52-11/16 (1338) 276 (125) R410A 10 lbs. 9 oz.(4.8) 73 (2.3) HP switch Compressor thermo, Overcurrent detection Overheating / Voltage protection D.B 23 to 115°F . [ D.B.−5 to 46°C ] *3 D.B. −13 to 70°F [D.B. −25 to 21°C ] 492 (150) 262 (80) 164 (50)*4 0 3/8 (9.52) 5/8 (15.88) Flared Flared *1 Rating conditions Cooling Indoor : D.B. 80°F/ W.B. 67 °F [D.B.26.7°C/ W.B. 19.4°C] Outdoor : D.B. 95°F [D.B. 35.0°C] Heating Indoor : D.B. 70°F [D.B. 21.1°C] Outdoor : D.B. 47°F/ W.B. 43°F [D.B. 8.3°C/ W.B. 6.1°C] *2 Conditions Heating Indoor : D.B. 70°F [D.B. 21.1°C] Outdoor : D.B. 17°F/ W.B. 15°F [D.B. −8.3°C/ W.B. −9.4°C] *3 D.B. 5 to 115°F [D.B. −15 to 46°C], when an optional Air Outlet Guide is installed. *4 131 ft [40 m], in case of installing outdoor unit lower than indoor unit. Note: Refer to the indoor unit's service manual for the indoor units specifications. Due to continuing improvement, above specification may be subject to change without notice. M-Series - H2i® MXZ Outdoor Units (November 2014) © 2014 Mitsubishi Electric US, Inc. H2i-MXZ-7 1. SPECIFICATIONS MXZ-8C48NAHZ Outdoor model OUTDOOR UNIT Cooling Capacity Rated*1 Rated power consumption*1 EER SEER Capacity Rated 47°F*1 Capacity 17°F*2 Capacity 5°F Rated power consumption 47°F*1 COP 47°F*1 HSPF IV(V) Connectable indoor units (Max.) Max. Connectable Capacity Power supply Breaker Size / Max. fuse size Min. circuit ampacity Sound level (Cool/Heat) External finish Refrigerant control Compressor Model Motor output Starting method Heat exchanger Fan (drive) × No. Fan motor output Fan Airflow Heating Standard performance Item Dimensions (H × W × D) REFRIGERANT PIPING Weight Refrigerant W D H Indoor type BTU/h W BTU/Wh BTU/Wh BTU/h BTU/h BTU/h W BTU/Wh BTU/Wh Non-Ducted 48,000 4,000 12.00 18.9 54,000 54,000 54,000 4,220 3.75 11.0/9.2 dB kW kW m³/min (CFM) in (mm) in (mm) in (mm) lb (kg) Charge lb (kg) Oil / Model oz (L) High pressure protection Protection Compressor protection devices Fan motor protection (cool) Guaranteed operation range (heat) Total Piping length (Max.) ft (m) Farthest ft (m) Max. Height difference ft (m) Chargeless length ft (m) Liquid in (mm) Piping diameter Gas in (mm) Indoor side Connection method Outdoor side MXZ-8C48NAHZ Mix Ducted 48,000 48,000 4,525 5,050 10.61 9.50 16.8 14.7 54,000 54,000 54,000 54,000 54,000 54,000 4,605 4,990 3.44 3.17 10.5/9.2 10.0/9.2 8 62,000 1 Phase 208 / 230 V, 60 Hz 50 A/ 52 A 42 A 51/ 54 Munsell 3Y 7.8 / 1.1 Linear Expansion Valve Hermetic ANB33FJSMT 3.4 Inverter Plate fin coil Propeller fan × 2 0.06 + 0.06 110 (3885) 41-11/32 (1050) 13+1 (330+25) 52-11/16 (1338) 276 (125) R410A 10 lbs. 9 oz. (4.8 ) 73 (2.3) HP switch Compressor thermo, Over current detection Overheating / Voltage protection D.B. 23 to 115°F [ D.B. −5 to 46°C]*3 D.B. −13 to 70°F [D.B. −25 to 21°C] 492 (150) 262 (80) 164 (50)*4 0 3/8 (9.52) 5/8 (15.88) Flared Flared *1 Rating conditions Cooling Indoor : D.B. 80°F/ W.B. 67°F [D.B. 26.7°C/ W.B. 19.4°C] Outdoor : D.B. 95°F [D.B. 35.0°C] Heating Indoor : D.B. 70°F [D.B. 21.1°C] Outdoor : D.B. 47°F/ W.B. 43°F [D.B. 8.3°C / W.B. 6.1°C] *2 Conditions Heating Indoor : D.B. 70°F [D.B. 21.1°C] Outdoor : D.B. 17°F/ W.B. 15°F [D.B. −8.3°C/ W.B. −9.4°C] *3 D.B. 5 to 115°F [D.B. −15 to 46°C], when an optional Air Outlet Guide is installed. *4 131 ft [40 m], in case of installing outdoor unit lower than indoor unit. Note: Refer to the indoor unit's service manual for the indoor units specifications. Due to continuing improvement, above specification may be subject to change without notice. H2i-MXZ-8 M-Series - H2i® MXZ Outdoor Units (November 2014) © 2014 Mitsubishi Electric US, Inc. 1. SPECIFICATIONS Branch Box PAC-MKA50BC PAC-MKA30BC Model name Connectable number of indoor units Power supply Input Running current External finish Width Depth Dimensions Height Weight Branch (indoor side)* Piping connection (Flare) Main (outdoor side) PAC-MKA50BC Maximum 5 kW A Liquid in (mm) in (mm) in (mm) lb (kg) in (mm) Gas in (mm) Liquid Gas in (mm) in (mm) PAC-MKA30BC Maximum 3 Single phase, 208/230 V, 60 Hz 0.003 0.05 Galvanized sheets 17-23/32 (450) 11-1/32 (280) 6-11/16 (170) 15 (6.7 ) 16 (7.4) [1/4(6.35) × 5 {A,B,C,D,E} [1/4(6.35) × 3 {A,B,C} [ 3/8(9.52) × 4 {A,B,C,D}, [ 1/2(12.7) × 1{E} [3/8(9.52) × 3 {A,B,C} [3/8 (9.52) [ 5/8 (15.88) *The piping connection size differs according to the type and capacity of indoor units. Match the piping connection size for indoor and branch box. If the piping connection size of branch box does not match the piping connection size of indoor units, use optional different-diameter (deformed) joints to the branch box side. (Connect deformed joint directly to the branch box side.) Due to continuing improvement, above specification may be subject to change without notice. M-Series - H2i® MXZ Outdoor Units (November 2014) © 2014 Mitsubishi Electric US, Inc. H2i-MXZ-9 1. SPECIFICATIONS Efficiency Ratings Model MXZ-2C20NAHZ MXZ-3C24NAHZ MXZ-3C30NAHZ MXZ-4C36NAHZ MXZ-5C42NAHZ MXZ-8C48NAHZ Configuration SEER EER HSPF COP @ 47° F COP @ 17° F Non-Ducted 17.0 13.50 9.8 4.00 2.77 Ducted 15.0 11.00 9.5 3.69 2.53 Non-Ducted 19.0 13.50 10.0 4.25 2.53 Ducted 15.5 10.00 9.0 3.80 2.51 Non-Ducted 18.0 12.50 11.0 4.00 2.65 Ducted 16.0 10.30 9.8 3.70 2.50 Non-Ducted 19.1 14.01 11.3 3.95 2.85 Ducted 15.8 11.32 10.1 3.10 2.30 Non-Ducted 19.0 13.42 11.0 4.10 2.85 Ducted 15.0 10.80 10.1 3.23 2.50 Non-Ducted 18.9 10.00 11.0 3.75 2.70 Ducted 14.7 9.5 10 3.17 2.40 Due to continuing improvement, above specification may be subject to change without notice. H2i-MXZ-10 M-Series - H2i® MXZ Outdoor Units (November 2014) © 2014 Mitsubishi Electric US, Inc. 1. SPECIFICATIONS 1-1. Compatibility Table OUTDOOR UNIT INDOOR UNIT MSZ-FE09NA 2C20NAHZ 3C24NAHZ 3C30NAHZ 4C36NAHZ 5C42NAHZ 8C48NAHZ ○ MSZ-FE12NA Wall Mounted M-Series ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ MSZ-FH09NA ○ ○ ○ ○ ○ ○ MSZ-FH12NA ○ ○ ○ ○ ○ ○ MSZ-FH15NA ○ ○ ○ ○ ○ ○ MSZ-FH18NA ○ ○ ○ ○ ○ MSZ-GE06NA ○ ○ ○ ○ ○ ○ MSZ-GE09NA ○ ○ ○ ○ ○ ○ MSZ-GE12NA ○ ○ ○ ○ ○ ○ MSZ-GE15NA ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ MSZ-GE18NA MSZ-GE24NA Floor Standing 4-way Cassette S-Series Ceiling Conceald MFZ-KA09NA ○ ○ ○ ○ ○ ○ MFZ-KA12NA ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ MFZ-KA18NA SLZ-KA09NA ○ ○ ○ ○ ○ ○ SLZ-KA12NA ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ SLZ-KA18NA SEZ-KD09NA ○ ○ ○ ○ ○ ○ SEZ-KD12NA ○ ○ ○ ○ ○ ○ SEZ-KD15NA ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ PEAD-A30AA ○ ○ ○ PEAD-A36AA ○ ○ ○ SEZ-KD18NA PLA-A12BA 4-way Cassette P-Series Ceiling Suspended Ceiling Conceald PLA-A18BA PLA-A24BA PLA-A30BA PLA-A36BA PCA-A24KA ○ PEAD-A24AA ○ MVZ-A12AA4 ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ MVZ-A30AA4 ○ ○ ○ MVZ-A36AA4 ○ ○ ○ MVZ-A18AA4 Vertical Multi Position MVZ-A24AA4 ○ Notes: • Minimum of two Indoor Units must be connected to the MXZ-2C20,3C24,3C30,4C36,5C42,8C48NAHZ. • Minimum installed capacity cannot be less than 12,000 Btu/h. • System can operate with only one Indoor Unit turned on. • May connect to any style indoor unit or combination. • Information provided at 208/230V. • Refer to the MXZ Technical & Service Manual for detailed specifications and additional information per Indoor Unit Combination. Due to continuing improvement, above specification may be subject to change without notice. M-Series - H2i® MXZ Outdoor Units (November 2014) © 2014 Mitsubishi Electric US, Inc. H2i-MXZ-11 1. SPECIFICATIONS 1-2. Cooling and Heating Capacity and Characteristics MXZ-4C36NAHZMXZ-5C42NAHZMXZ-8C48NAHZ 1-2-1. Method for obtaining system cooling and heating capacity: To obtain the system cooling and heating capacity and the electrical characteristics of the outdoor unit, first add up the ratings of all the indoor units connected to the outdoor unit (see table below), and then use this total to find the standard capacity with the help of the tables on 1-4. STANDARD CAPACITY DIAGRAM. (1) Capacity of indoor unit M series P series SEZ SLZ MVZ Model Number for Model 06 Model 09 Model 12 Model 15 Model 18 Model 24 Model 30 Model 36 indoor unit 14.0*1 17.2*3 ─ ─ 6.0 9.0 12.0 22.5 2 15.0* 18.0*4 ─ ─ ─ Model Capacity 12.0 18.0 24.0 30.0 35.0 ─ ─ ─ ─ [kBtu/h] 8.1 11.5 14.1 17.2 ─ ─ ─ ─ ─ 8.4 11.1 15.0 ─ ─ ─ 12.0 18.0 24.0 30.0 36.0 *1 The value is for MSZ-GE15NA. *2 The value is for MSZ-FH15NA. *3 The value is for MSZ-GE/FH18NA. *4 The value is for MSZ-FE18NA or MFZ-KA18NA. (2) Sample calculation 1 System assembled from indoor and outdoor unit (in this example the total capacity of the indoor units is greater than that of the outdoor unit) • Outdoor unit MXZ-5C42NAHZ • Indoor unit MSZ-GE09NA × 2 + MSZ-FH15NA ×2 2 According to the conditions in 1, the total capacity of the indoor unit will be: 9.0 × 2 + 15.0 × 2 = 48.0 3 The following figures are obtained from the 16.8 total capacity of indoor units, referring the standard capacity diagram in "4-3-3. MXZ-5C42NAHZ <cooling>" and "4-3-4. MXZ-5C42NAHZ <heating>". Capacity (kBTU/h) Outdoor unit power consumption (kW) Outdoor unit current (A)/ 230 V Cooling Heating Cooling Heating Cooling Heating A 42.0 B 48.0 3.46 4.37 15.26 19.31 1-2-2. Method for obtaining the heating and cooling capacity of an indoor unit: (1) The capacity of each indoor unit (kW) = the capacity A (or B ) X model capacity total model capacity of all indoor units (2) Sample calculation (using the system described above in 4-1-1. (2) ): During heating: During cooling: • The total model capacity of the indoor unit is: 9.0 × 2 + 15.0 × 2 = 48.0 kBTU/h Therefore, the capacity of MSZ-GE09NA and MSZ-FH15NA will be calculated as follows by using the formula in 4-1-2. (1): 9.0 = 7.88 kBTU/h 48.0 15.0 Model 15 = 42.0 × = 13.13 kBTU/h 48.0 Model 09 = 42.0 × • The total model capacity of indoor unit is: 10.9 × 2 + 18.0 × 2 = 57.8 kBTU/h Therefore, the capacity of MSZ-GE09NA and MSZFH15NA will be calculated as follows by using the formula in 4-1-2. (1): 10.9 Model 25 = 48.0 × 57.8= 9.05 kBTU/h 18.0 Model 50 = 48.0 × 57.8 = 14.95 kBTU/h Due to continuing improvement, above specification may be subject to change without notice. H2i-MXZ-12 M-Series - H2i® MXZ Outdoor Units (November 2014) © 2014 Mitsubishi Electric US, Inc. 1. SPECIFICATIONS 1-3. Standard Operation Data (Reference Data) MXZ-4C36NAHZMXZ-5C42NAHZMXZ-8C48NAHZ Outdoor unit model Operation MXZ-4C36NAHZ Indoor Ambient temperature Outdoor Indoor unit Operating conditions No. of connected units 70°F / 60°F 80°F / 67°F 70°F / 60°F 80°F / 67°F 70°F / 60°F 95°F / 75°F 47°F / 43°F 95°F / 75°F 47°F / 43°F 95°F / 75°F 47°F / 43°F To t a l p i p e length Fan speed Amount of refrigerant 4 4 4 4 4 4 Unit — 09 × 4 09 × 2 + 12 ×2 12 × 4 9.84 (3) 9.84 (3) 9.84 (3) 14.76 (4.5) 14.76 (4.5) 14.76 (4.5) 68.90 (21) 68.90 (21) 68.90 (21) — Hi Hi Hi lb oz (kg) 17 lb 7 oz (7.9) 17 lb 7 oz (7.9) 17 lb 7 oz (7.9) Main pipe Branch pipe MXZ-8C48NAHZ 80°F / 67°F No. of units in operation Model Piping Outdoor unit DB/WB MXZ-5C42NAHZ m Electric current A Voltage V Compressor frequency Hz 59 74 70 80 86 91 14.1 18.7 17.2 230 19.1 22.1 230 21.9 230 LEV opening Indoor unit Pulse 112 128 129 128 112 132 Pressure High pressure/Low pressure MPa 2.57/ 0.98 2.78/ 0.64 2.72/ 0.80 2.80/ 0.56 2.83/ 0.77 2.82/ 0.55 Discharge 62.1 66.4 64.8 63.2 69.8 65.1 Heat exchanger outlet 38.2 2.6 38.8 2.0 40.9 1.3 10.3 2.3 9.7 1.6 8.4 0.8 8.4 1.1 7.4 0.4 5.8 −0.8 LEV inlet 21.1 39.7 28.7 37.9 21.7 37.1 Heat exchanger inlet 12.3 59.4 9.8 55.7 8.6 57.0 Temp. of each section Outdoor unit Accumulator inlet Compressor inlet Indoor unit °C Due to continuing improvement, above specification may be subject to change without notice. M-Series - H2i® MXZ Outdoor Units (November 2014) © 2014 Mitsubishi Electric US, Inc. H2i-MXZ-13 1. SPECIFICATIONS 1-4. Standard Capacity Diagram Before calculating the sum of total capacity of indoor units, please convert the value into the kW model capacity following the formula on "1-2-1. Method for obtaining system cooling and heating capacity". 1-4-1. MXZ-4C36NAHZ <cooling> Capacity (kBTU/h) 40 35 30 25 20 15 10 5 0 6 12 18 24 30 36 42 48 54 48 54 Total capacity of indoor units (kBTU/h) 4.0 Input (kBTU/h) 3.5 3.0 2.5 2.0 1.5 1.0 0.5 0.0 6 12 18 24 30 36 42 Total capacity of indoor units (kBTU/h) 18 Current (A) 16 14 230 V 12 208 V 10 8 6 4 2 0 6 12 18 24 30 36 42 48 54 Total capacity of indoor units (kBTU/h) Due to continuing improvement, above specification may be subject to change without notice. H2i-MXZ-14 M-Series - H2i® MXZ Outdoor Units (November 2014) © 2014 Mitsubishi Electric US, Inc. 1. SPECIFICATIONS 1-4-2. MXZ-4C36NAHZ <heating> Capacity (kBTU/h) 50 45 40 35 30 25 20 15 10 5 0 6 12 18 24 30 36 42 48 54 48 54 Total capacity of indoor units (kBTU/h) 5.0 Input (kBTU/h) 4.5 4.0 3.5 3.0 2.5 2.0 1.5 1.0 0.5 0.0 6 12 18 24 30 36 42 Total capacity of indoor units (kBTU/h) 25 230 V Current (A) 20 208 V 15 10 5 0 6 12 18 24 30 36 42 48 54 Total capacity of indoor units (kBTU/h) Due to continuing improvement, above specification may be subject to change without notice. M-Series - H2i® MXZ Outdoor Units (November 2014) © 2014 Mitsubishi Electric US, Inc. H2i-MXZ-15 1. SPECIFICATIONS 1-4-3. MXZ-5C42NAHZ <cooling> Capacity (kBTU/h) 45.0 40.0 35.0 30.0 25.0 20.0 15.0 10.0 5.0 0.0 6 12 18 24 30 36 42 48 54 60 54 60 Total capacity of indoor units (kBTU/h) 4.5 Input (kBTU/h) 4.0 3.5 3.0 2.5 2.0 1.5 1.0 0.5 0.0 6 12 18 24 30 36 42 48 Total capacity of indoor units (kBTU/h) 25.0 208 V Current (A) 20.0 230 V 15.0 10.0 5.0 0.0 6 12 18 24 30 36 42 48 54 60 Total capacity of indoor units (kBTU/h) Due to continuing improvement, above specification may be subject to change without notice. H2i-MXZ-16 M-Series - H2i® MXZ Outdoor Units (November 2014) © 2014 Mitsubishi Electric US, Inc. 1. SPECIFICATIONS 1-4-4. MXZ-5C42NAHZ <heating> Capacity (kBTU/h) 60.0 50.0 40.0 30.0 20.0 10.0 0.0 6 12 18 24 30 36 42 48 54 60 54 60 Total capacity of indoor units (kBTU/h) 6.0 Input (kBTU/h) 5.0 4.0 3.0 2.0 1.0 0.0 6 12 18 24 30 36 42 48 Total capacity of indoor units (kBTU/h) Current (A) 30.0 25.0 208 V 20.0 230 V 15.0 10.0 5.0 0.0 6 12 18 24 30 36 42 48 54 60 Total capacity of indoor units (kBTU/h) Due to continuing improvement, above specification may be subject to change without notice. M-Series - H2i® MXZ Outdoor Units (November 2014) © 2014 Mitsubishi Electric US, Inc. H2i-MXZ-17 1. SPECIFICATIONS 1-4-5. MXZ-8C48NAHZ <cooling> Capacity (kBTU/h) 60.0 50.0 40.0 30.0 20.0 10.0 0.0 6 12 18 24 30 36 42 48 54 60 66 54 60 66 Total capacity of indoor units (kBTU/h) 6.0 Input (kBTU/h) 5.0 4.0 3.0 2.0 1.0 0.0 6 12 18 24 30 36 42 48 Total capacity of indoor units (kBTU/h) 30.0 Current (A) 25.0 208 V 230 V 20.0 15.0 10.0 5.0 0.0 6 12 18 24 30 36 42 48 54 60 66 Total capacity of indoor units (kBTU/h) Due to continuing improvement, above specification may be subject to change without notice. H2i-MXZ-18 M-Series - H2i® MXZ Outdoor Units (November 2014) © 2014 Mitsubishi Electric US, Inc. 1. SPECIFICATIONS 1-4-6. MXZ-8C48NAHZ <heating> Capacity (kBTU/h) 60.0 50.0 40.0 30.0 20.0 10.0 0.0 6 12 18 24 30 36 42 48 54 60 66 54 60 66 Total capacity of indoor units (kBTU/h) 6.0 Input (kBTU/h) 5.0 4.0 3.0 2.0 1.0 0.0 6 12 18 24 30 36 42 48 Total capacity of indoor units (kBTU/h) Current (A) 30.0 25.0 208 V 20.0 230 V 15.0 10.0 5.0 0.0 6 12 18 24 30 36 42 48 54 60 66 Total capacity of indoor units (kBTU/h) Due to continuing improvement, above specification may be subject to change without notice. M-Series - H2i® MXZ Outdoor Units (November 2014) © 2014 Mitsubishi Electric US, Inc. H2i-MXZ-19 2. EXTERNAL DIMENSIONS MXZ-2C20NAHZ Unit: mm <in> Due to continuing improvement, above specification may be subject to change without notice. H2i-MXZ-20 M-Series - H2i® MXZ Outdoor Units (November 2014) © 2014 Mitsubishi Electric US, Inc. 2. EXTERNAL DIMENSIONS MXZ-3C24NAHZMXZ-3C30NAHZ Unit: mm <in> Due to continuing improvement, above specification may be subject to change without notice. M-Series - H2i® MXZ Outdoor Units (November 2014) © 2014 Mitsubishi Electric US, Inc. H2i-MXZ-21 Min. 150mm<5-29/32> Service space 15 <19/32> Min. Front trunking hole (Knockout) Conduit hole ({37<1-15/32>Knockout) 60 <2-3/8> Front piping hole (Knockout) 92 <3-5/8> 75 <2-15/16> {92 > <3-5/8 53 <2-3/32> 92 <3-5/8> 29 <1-5/32> 55 <2-3/16> {92 <3-5/8> Right piping hole (Knockout) Conduit hole ( {24<15/16>Knockout) 55 <2-3/16> Piping Knockout Hole Details *1.......Indication of STOP VALVE connection location. 60 <2-3/8> 5 <3/16> 30 <1-3/16> Max. Min. Right trunking hole (Knockout) Conduit hole ( {37<1-15/32>Knockout) 60 <2-3/8> Conduit hole ( { 24<15/16>Knockout) 500 <19-11/16> Handle for moving 500 <19-11/16> Min. 1……Refrigerant GAS pipe connection (FLARE){15.88 (5/8F) 2……Refrigerant LIQUID pipe connection (FLARE){9.52 (3/8F) Example of Notes Min. 1000mm<39-3/8> Min. 15mm<19/32> Rear trunking hole (Knockout) 55 <2-3/16> FOUNDATION 5<3/16> 60 <2-3/8> 73 <2-7/8> Min. 15mm<19/32> 92 <3-5/8> <Foundation bolt height> 75 <2-15/16> 92 <3-5/8> Rear piping hole (Knockout) { 92 8> <3-5/ Conduit hole ( { 37<1-15/32>Knockout) 1/2 inch Conduit attachment { 22.2<7/8> Scale 1:5 101.5 <4> 24 <15/16> 110 <4-11/32> 45 <1-25/32> 1 inch Conduit attachment mm<inch> { 34.5<1-23/64> 60 <2-3/8> 330 <13> Handle for moving Side Air Intake When installing the conduit. Set the attachment to the inner side of each panel. Side Air Intake Handle for moving Conduit hole ( { 24<15/16>Knockout) 60 <2-3/8> Rear Air Intake 4 PIPING-WIRING DIRECTIONS Piping and wiring connections can be made from 4 directions: FRONT, Right, Rear and Below. 5<3/16> FREE 3 FOUNDATION BOLTS 60 <2-3/8> Min. Please secure the unit firmly with 4 foundation (M10<W3/8>) bolts. (Bolts and washers must be purchased locally.) 5<3/16> 150 <5-29/32> 2 SERVICE SPACE 55 <2-3/16> 1338 <52-11/16> 24.7 <31/32> 632 <24-7/8> 369 <14-17/32> Dimensions of space needed for service access are shown in the below diagram. 73 <2-7/8> 26 <1-1/32> 55 <2-3/16> 27 <1-1/16> 27 <1-1/16> 26 <1-1/32> 73 <2-7/8> 26 <1-1/32> 160 <6-5/16> 362 <14-1/4> 225 <8-27/32> 160 <6-5/16> 160 <6-5/16> 42 <1-21/32> 56 <2-7/32> Drain hole (5-{33<1-5/16>) For the branch box power supply For the transmission line Bottom piping hole (Knockout) 2 1 Handle for moving Service panel Ground for the branch box power supply For concentration control Rear piping cover Front piping cover Air intake Ground for the transmission line Ground for concentration control For the power supply Terminal connection From left to right 53 <2-3/32> 33.2 <1-5/16> 0 56 <2-7/32> 2-U Shaped notched holes (Foundation Bolt M10<W3/8>) 2-12×36 Oval holes (Foundation Bolt M10<W3/8>) 225 <8-27/32> 81 <3-3/16> Ground for the power supply ("GR"marking position) 1050 <41-11/32> Air Discharge Installation Feet 70 <2-3/4> Rear Air Intake 417 <16-13/32> 600 <23-5/8> MXZ-4C36NAHZMXZ-5C42NAHZMXZ-8C48NAHZ 27 <1-1/16> 86 <3-3/8> 25 <1> 26 <1-1/32> 154 <6-1/16> 136 <5-11/32> 19 <3/4> 370 <14-9/16> 28 <1-3/32> 426 <16-25/32> *1 1 FREE SPACE (Around the unit) 1067 <42> H2i-MXZ-22 510 <20-3/32> *1 The diagram below shows a basic example. Explantion of particular details are given in the installation manuals etc. 2. EXTERNAL DIMENSIONS Unit: mm <in> Due to continuing improvement, above specification may be subject to change without notice. M-Series - H2i® MXZ Outdoor Units (November 2014) © 2014 Mitsubishi Electric US, Inc. 2. EXTERNAL DIMENSIONS Branch Box PAC-MKA50BC Unit: mm <in> When installing the conduit. Set the attachment to the inner side of each panel. 58 <2-9/32> SUSPENSION BOLT PITCH 320 <12-5/8> 28 <1-3/32> 48 <1-7/8> 24 <15/16> 129 <5-3/32> 48 <1-7/8> 24 <15/16> 5- { 22<7/8> 1/2 inch Conduit attachment 12 <1/2> 17 <21/32> 15 <19/32> 12 <15/32> REFRIGERANT PIPE FLARED CONNECTION TO OUTDOOR UNIT A B C D E LIQUID PIPE 1/4F 1/4F 1/4F 1/4F 1/4F 3/8F GAS PIPE 3/8F 3/8F 3/8F 3/8F 1/2F 5/8F 24 <1> 402 <15-7/8> SUSPENSION BOLT : W3/8(M10) SUSPENSION BOLT PITCH 105 <4-1/8> 20 <25/32> 66 <2-19/32> 91 <3-19/32> B C A B A TERMINAL BLOCK TO INDOOR UNIT 5-ELECTRIC WIRE INLET 25 25 25 25 <1> <1> <1> <1> 70 70 70 70 <2-3/4> <2-3/4> <2-3/4> <2-3/4> TB3E TB2B 25 <1> CONTROL COVER TO OUTDOOR UNIT SERVICE PANEL (for LEV,THERMISTOR) TB3D C D 83 87 70 <3-9/32> <3-7/16> <2-3/4> TB3B D E TERMINAL BLOCK TO M-NET UNIT 40 <1-17/32> 280 <11-1/32 > TB3C E TO INDOOR UNIT 96 <3-25/32> TB3A 65 <2-9/16> 67 <2-9/16> 73 <2-7/8> 111 <4-3/8> 450 <17-23/32> TB5 170 <6-11/16> 46 <1-13/16> (1:2) TERMINAL BLOCK TO OUTDOOR UNIT CONDUIT PLATE PAC-MKA30BC When installing the conduit. Set the attachment to the inner side of each panel. SUSPENSION BOLT PITCH 320 <12-5/8> 58 <2-9/32> 5- { 22<7/8> 129 <5-3/32> 48 <1-7/8> 1/2 inch Conduit attachment 15 <19/32> 12 <15/32> 12 <1/2> 48 <1-7/8> 24 <15/16> 105 <4-1/8> 24 <1> TO OUTDOOR UNIT 3/8F 5/8F 24 <15/16> REFRIGERANT PIPE FLARED CONNECTION A B C LIQUID PIPE 1/4F 1/4F 1/4F GAS PIPE 3/8F 3/8F 3/8F 28 <1-3/32> 66 <2-19/32> 17 <21/32> SUSPENSION BOLT : W3/8(M10) SUSPENSION BOLT PITCH 402 <15-7/8> 20 <25/32> (1:2) 91 <3-19/32> TO INDOOR UNIT 25 <1> B A 25 <1> 70 70 <2-3/4> <2-3/4> 5-ELECTRIC WIRE INLET A TERMINAL BLOCK TO INDOOR UNIT TB3C 25 <1> B TERMINAL BLOCK TO M-NET UNIT 40 <1-17/32> TB3B CAP C 280 <11-1/32> 87 70 <3-7/16> <2-3/4> TB3A C 83 <3-9/32> TB2B 65 <2-9/16> CAP 96 <3-25/32> 111 <4-3/8> 73 <2-7/8> 208 <8-3/16> TB5 170 <6-11/16> 46 <1-13/16> 450 <17-23/32> TO OUTDOOR UNIT SERVICE PANEL (for LEV.THERMISTOR) CONTROL COVER CONDUIT PLATE TERMINAL BLOCK TO OUTDOOR UNIT Due to continuing improvement, above specification may be subject to change without notice. M-Series - H2i® MXZ Outdoor Units (November 2014) © 2014 Mitsubishi Electric US, Inc. H2i-MXZ-23 4. ELECTRICAL WIRING DIAGRAMS MXZ-2C20NAHZ Due to continuing improvement, above specification may be subject to change without notice. H2i-MXZ-24 M-Series - H2i® MXZ Outdoor Units (November 2014) © 2014 Mitsubishi Electric US, Inc. 4. ELECTRICAL WIRING DIAGRAMS MXZ-3C24NAHZMXZ-3C30NAHZ Due to continuing improvement, above specification may be subject to change without notice. M-Series - H2i® MXZ Outdoor Units (November 2014) © 2014 Mitsubishi Electric US, Inc. H2i-MXZ-25 3 CNDC (PNK) S M2 1 CNF2 7(WHT) RED YLW 2 POWER SUPPLY ~208 / 230V 60Hz TO BRANCH BOX B2 B1 TB1B GR L2 L1 TB1 FUSE2 FUSE1 FOR CENTRALIZED CONTROL DC 30V(Non-polar) S M2 M1 YLW TB7 t゜ t゜ t゜ 1 3 63LS (BLU) 2 1 2 CN4 (WHT) SV1 3 SV1 1 (GRY) W V U W GRN/YLW BLU RED SV2 3 SV2 1 (BLU) MC MS 3~ V 1 3 63H (YLW) U t゜ 7 + + - DCL 3 2 ~ ~ IGBT 2 1 CN4 (WHT) 1 2 CNDC (PNK)3 DCL2 DCL1 P2 N2 CN2 (RED) 2 M M 5 2 EI E4 1 3 2 52C 52C NI CN52C 3(RED) P. B. 3 1 3 1 2 MXZ-8C48NAHZ MXZ-5C42NAHZ MXZ-4C36NAHZ MODELS ON OFF ON OFF ON OFF 56 56 56 SW2 ON OFF ON OFF ON OFF 123456 123456 123456 SW4 ON OFF ON OFF ON OFF 12 12 12 SW8 The black square( )indicates a switch position. BLK 2 BLK 2 ※1 MODEL SELECTION LI 4 LED2 1 4 CN2 (WHT) BLK TB1 CN1 (WHT) 5 3 1 M-NET P.B. CN102 (WHT) 1 4 LED1 ※1 ※1 SW8 SW2 ※1 SW6 SW4 SW3 SW7 SW1 SW5 is the switch position. SWU2 SWU1 SW9 CNS1 CNS2 CN41 CN40 (YLW) (RED) (WHT) (WHT) 1 4 1 2 1 2 1 4 CN51 (WHT) 1 1 5 CNLVB (RED) LEV-B LEV-A 3 1 5 CNLVA CN52C (WHT) (RED) 1 3 3 1 LED3 3 1 3 SS 1 2 CNAC (WHT) (RED) TH8 1 7 BH F2 F1 7 1 CN3D CN3S CN3N (WHT) (RED) (BLU) CN2 1 (RED) 7 1 3 1 4 1 2 2 1 1 2 63HS TH7/6 TH3 TH4 TH2 (WHT) (BLK) (RED) (WHT) (WHT) TRANS 3 21S4 1 (GRN) 21S4 3 52C 1 (BLK) 2 2 M1 RED TB3 1 1 CNF1 7(WHT) TO BRANCH BOX CONNECTING WIRES DC 30V(Non-polar) MF2 MS 3~ 1 X503 MF1 MS 3~ X505 t゜ t゜ WHT X502 BLK WHT RED X501 63H WHT X504 TH2 BLK 63LS 63HS TH7 TH6 TH3 TH4 BLK E3 CNAC2 (RED) E2 H2i-MXZ-26 CNAC1 (WHT) MULTI. B. SYMBOL NAME 3 21S4 2 52C 4 SV1 5 SV2 7 ー 6 ー 8 Always lit Trouble Serial transmission trouble Compressor temperature trouble High pressure trouble Excessive refrigerant replenishment Insufficient refrigerant trouble Blocked valve in cooling mode Four-way valve disconnection trouble Drain pump trouble Drain sensor trouble (THd) Overcurrent trouble (Overload, compressor lock) Fan controller trouble (Indoor unit) Compressor overcurrent trouble Inverter trouble Overheat protection of heat sink Power module trouble or Overcurrent trouble Check code Trouble 4400 Fan controller trouble (Outdoor) 5101 Air inlet sensor trouble (TH21) or Compressor temperature sensor trouble (TH4) 5102 Liquid pipe temp.sensor trouble (TH22) or Suction pipe temperature sensor trouble (TH6) 5103 Gas pipe temperature sensor trouble (TH23) 5105 Piping temperature sensor trouble (TH3) 5106 Ambient temperature sensor trouble (TH7) 5109 HIC piping temperature sensor trouble (TH2) 5110 IGBT heat sink temperature sensor trouble (TH8) 5201 High Pressure sensor trouble (63HS) 5202 Low Pressure sensor trouble (63LS) Current sensor trouble 5300 6600 Dupricated unit address setting NAME Check code Trouble 6602 Transmission error (Transmission processor hardware error) 6603 Transmission error (Transmission route BUSY) 6606 Transmission and reception error (Communication trouble with transmission processor) 6607 Transmission and reception error (No ACK error) 6608 Transmission and reception error (No responsive frame error) 7100 Total capacity error 7101 Capacity code error 7102 Connecting unit number error 7105 Address set error 7111 Remote controller sensor trouble 7130 Combination error 〔Example〕 When the compressor and SV1 are turned during cooling operation. 1 23 45 67 8 Switch〈Function Selection〉 Switch〈Model Selection〉 Switch〈Function Selection〉 Switch〈Unit Address Selection, 1st digit〉 Switch〈Unit Address Selection, 2nd digit〉 Connector〈Branch box/Outdoor Transmission Line〉 Connector〈Centralized Control Transmission Line〉 Connector〈Base heater〉 Connector〈Connection For Option〉 Connector〈Connection For Option〉 Connector〈Connection For Option〉 Connector〈Connection For Option〉 LED〈Operation Inspection Display〉 LED〈Power Supply to Main Microcomputer〉 Fuse〈T6,3AL250V〉 Relay M-NET Power Circuit Board ConnectionTerminal〈Ground〉 NOTES: 1.Refer to the wiring diagrams of the indoor units for details on wiring of each indoor unit. 2.Self-diagnosis function The indoor and outdoor units can be diagnosed automatically using the self-diagnosis switch (SW1) and LED1, LED2 (LED indication) found on the multi-controller of the outdoor unit. LED indication : Set all contacts of SW1 to OFF. ! WARNING: When the main supply is turned off, the voltage [340 V] in the main capacitor will drop to 20 V in approx. 2 minutes (input voltage: 230 V). When servicing, make sure that LED1, LED2 on the outdoor circuit board goes out, and then wait for at least 1 minute. • Components other than the outdoor board may be faulty: Check and take corrective action, referring to the service manual. Do not replace the outdoor board without checking. Cautions when servicing • Use copper supply wires. Caution for electrical work 1508 2502 2503 4100 4116 4210 4220 4230 4250 Check code 0403 1102 1302 1500 1501 ● When fault requiring inspection has occurred The LED alternately indicates the inspection code and the location of the unit in which the fault has occurred. Bit 1 Compressor Indication operated SYMBOL SW7 Thermistor〈Suction Pipe〉 SW8 Thermistor〈Ambient〉 SW9 Thermistor〈Heat Sink〉 Electronic Expansion Valve SWU1 Reactor SWU2 Power Circuit Board CNS1 Connection Terminal〈U/V/W-Phase〉 CNS2 Connection Terminal〈L-Phase〉 SS Connection Terminal〈N-Phase〉 CN3D CN3S Connection Terminal〈Reactor〉 CN3N Power Module Connection Terminal〈Ground〉 CN51 Controller Circuit Board LED1,LED2 LED3 Switch〈Display Selection〉 Switch〈Function Selection〉 F1,F2 X501~505 Switch〈Test Run〉 M-NET P.B. Switch〈Model Selection〉 TB1 Switch〈Function Selection〉 Switch〈Function Selection〉 ● During normal operation The LED indicates the drive state of the controller in the outdoor unit. NAME Terminal Block 〈Power Supply〉 TH6 Terminal Block 〈Branch Box〉 TH7 Terminal Block TH8 〈Branch box/Outdoor Transmission Line〉LEV-A,LEV-B TB7 Terminal Block DCL 〈Centralized Control Transmission Line〉P.B. U/V/W FUSE1,FUSE2 Fuse 〈T20AL250V〉 LI MC Motor For Compressor NI MF1,MF2 Fan Motor 21S4 Solenoid Valve〈Four-Way Valve〉 DCL1,DCL2 IGBT 63H High Pressure Switch EI,E2,E3,E4 63HS High Pressure Sensor MULTI.B. 63LS Low Pressure Sensor SW1 Solenoid Valve〈Bypass Valve〉 SV1 SW2 Solenoid Valve〈Switching Valve〉 SV2 SW3 BH Base heater SW4 Thermistor〈Hic Pipe〉 TH2 SW5 Thermistor〈Outdoor Liquid Pipe〉 TH3 SW6 Thermistor〈Compressor〉 TH4 SYMBOL TB1 TB1B TB3 4. ELECTRICAL WIRING DIAGRAMS MXZ-4C36NAHZMXZ-5C42NAHZMXZ-8C48NAHZ Due to continuing improvement, above specification may be subject to change without notice. M-Series - H2i® MXZ Outdoor Units (November 2014) © 2014 Mitsubishi Electric US, Inc. 4. ELECTRICAL WIRING DIAGRAMS Branch Box PAC-MKA50BCPAC-MKA30BC Due to continuing improvement, above specification may be subject to change without notice. M-Series - H2i® MXZ Outdoor Units (November 2014) © 2014 Mitsubishi Electric US, Inc. H2i-MXZ-27 5. REFRIGERANT SYSTEM DIAGRAMS MXZ-2C20NAHZ R.V.coil OFF ON Refrigerant flow in heating Refrigerant flow in cooling Accumulator Compressor Oil separator Compressor shell temperature thermistor RT62 Service port High pressure switch Union Header(Gas) Service port Φ3/8 Indoor unit A 4-way valve Stop valve (with service port) Header(Evaporator) 2-way solenoid valve Φ3/8 Outdoor heat exchanger Capillary tube O.D.0.10 x I.D.0.02 x 39.37 (Ø2.5 x Ø0.6 x 1000) Outdoor heat exchanger temperature thermistor RT68 Indoor unit B Union Φ1/4 Strainer #100 Capillary tube O.D.0.16 x I.D.0.11 x 3.94 (Ø4.0 x Ø2.8 x 100) LEV-A Indoor unit A Strainer #100 Φ1/4 Strainer #100 Defrost temperature thermistor RT61 Capillary tube Stop valve Ambient temperature thermistor RT65 Distributor LEV-B Indoor unit B Due to continuing improvement, above specification may be subject to change without notice. H2i-MXZ-28 M-Series - H2i® MXZ Outdoor Units (November 2014) © 2014 Mitsubishi Electric US, Inc. 5. REFRIGERANT SYSTEM DIAGRAMS MXZ-3C24NAHZMXZ-3C30NAHZ R. V. coil OFF ON Refrigerant flow in heating Refrigerant flow in cooling Accumulator Compressor Service port Compressor shell temperature thermistor RT62 Oil separator High pressure switch Union Indoor unit A Indoor unit B Indoor unit C Header(Gas) Service port Φ1/2 Φ3/8 4-way valve Stop valve (with service port) Header(Evaporator) 2-way solenoid valve Φ3/8 Union Strainer Φ1/4 #100 LEV-A Strainer #100 Strainer #100 LEV-B Strainer Φ1/4 #100 LEV-C Indoor unit B Indoor unit C Outdoor heat exchanger temperature thermistor RT68 Capillary tube O.D.0.16 x I.D.0.11 x 3.94 (Ø4.0 x Ø2.8 x 100) Indoor unit A Φ1/4 Outdoor heat exchanger Capillary tube O.D.0.10 x I.D.0.02 x 39.37 (Ø2.5 x Ø0.6 x 1000) Defrost temperature thermistor RT61 Capillary tube Stop valve Ambient temperature thermistor RT65 Distributor Due to continuing improvement, above specification may be subject to change without notice. M-Series - H2i® MXZ Outdoor Units (November 2014) © 2014 Mitsubishi Electric US, Inc. H2i-MXZ-29 5. REFRIGERANT SYSTEM DIAGRAMS MXZ-4C36NAHZMXZ-5C42NAHZMXZ-8C48NAHZ Thermistor(TH-A–E) <Gas pipe temperature> 4-Way Valve (21S4) Strainer Room temperature thermistor (TH1 or RT11) Ball valve High pressure Oil separator switch(63H) Solenoid valve(SV1) <Bypass> Strainer Check valve Strainer Capillary tube Thermistor(TH4) <Compressor> Solenoid valve(SV2) <Switching> LEV-A~E (Linear expansion) Service port Strainer Accumulator Low pressure sensor(63LS) Thermistor(TH2) <HIC pipe> Stop valve Strainer Strainer Compressor Branch box Thermistor(TH8) <Heat Sink> HIC Strainer LEV-B LEV-A Strainer Refrigerant flow in cooling Reftigerant flow in heating Capillary tube2 Indoor Distributor Thermistor(TH3) <Outdoor Liquid pipe> High pressure sensor(63HS) Thermistor(TH6) <Suction pipe> Condenser / evaporator temperature thermistor Pipe temperature thermistor (TH2 or RT13) Thermistor(TH7) <Ambient> Check valve Service port Outdoor unit Unit: in (mm) MXZ-4C36NAHZ Outdoor unit MXZ-5C42NAHZ MXZ-8C48NAHZ Branch box Capillary tube 1 (For return of oil from oil separator) Capillary tube 2 behind LEV (in cooling mode) [0.098 o [0.031 o L(39-1/2) ([2.5 o [0.8 o L1000) PAC-MKA50BC ([0.157 o [0.117 o L(5-1/8)) o 5 (([4 o [3.0 o L130) o 5) PAC-MKA30BC ([0.157 o [0.117 o L(5-1/8)) o 3 (([4 o [3.0 o L130) o 3) Due to continuing improvement, above specification may be subject to change without notice. H2i-MXZ-30 M-Series - H2i® MXZ Outdoor Units (November 2014) © 2014 Mitsubishi Electric US, Inc. 5. REFRIGERANT SYSTEM DIAGRAMS Piping Connection Size MXZ-4C36NAHZMXZ-5C42NAHZMXZ-8C48NAHZ B A Liquid (mm) 9.52 Gas (mm) 15.88 The pipe connection size differs according to the type and capacity of indoor units. Match the piping connection size of branch box with indoor unit. If the piping connection size of branch box does not match the piping connection size of indoor unit, use optional different-diameter (deformed) joints to the branch box side. (Connect deformed joint directly to the branch box side.) ■ In case of using 1-branch box Flare connection employed (No. brazing) Branch box A B B B B B ■ In case of using 2-branch boxes ■ installation procedure (2 branch pipe (joint)) Refer to the installation manuals of MSDD-50AR-E and MSDD-50BR-E. 2 branches pipe (joint) : optional parts A A Branch box #1 A B B B B B Branch box #2 Due to continuing improvement, above specification may be subject to change without notice. M-Series - H2i® MXZ Outdoor Units (November 2014) © 2014 Mitsubishi Electric US, Inc. H2i-MXZ-31 6. CAPACITY CORRECTION CURVE BY TEMPERATURE DUE TO CONTINUING RESEARCH AND PRODUCT IMPROVEMENT, SPECIFICATIONS AND DATA ARE STILL UNDER REVIEW Due to continuing improvement, above specification may be subject to change without notice. H2i-MXZ-32 M-Series - H2i® MXZ Outdoor Units (November 2014) © 2014 Mitsubishi Electric US, Inc. 7. CAPACITY CORRECTION TABLE BY TEMPERATURE DUE TO CONTINUING RESEARCH AND PRODUCT IMPROVEMENT, SPECIFICATIONS AND DATA ARE STILL UNDER REVIEW Due to continuing improvement, above specification may be subject to change without notice. M-Series - H2i® MXZ Outdoor Units (November 2014) © 2014 Mitsubishi Electric US, Inc. H2i-MXZ-33 8. CAPACITY CORRECTION CURVE BY REFRIGERANT PIPING LENGTH MXZ-4C36NAHZMXZ-5C42NAHZMXZ-8C48NAHZ (1) During cooling, obtain the ratio (and the equivalent piping length) of the outdoor units rated capacity and the total in-use indoor capacity, and find the capacity ratio corresponding to the standard piping length from Figure 3. Then multiply by the cooling capacity from Figure 1 to obtain the actual capacity. (2) During heating, find the equivalent piping length, and find the capacity ratio corresponding to standard piping length from Figure 3. Then multiply by the heating capacity from Figure 2 to obtain the actual capacity. Capacity Correction Factor Fig. 1 Capacity correction curve Cooling Heating 1.00 Heating 4C36, 5C42, 8C48 models Capacity ratio 0.95 0.90 Cooling 4C36 model 0.85 Cooling 5C42 model Cooling 8C48 model 0.80 0.75 0.70 0 70 130 195 260 [ft] Equivalent pipe length Due to continuing improvement, above specification may be subject to change without notice. H2i-MXZ-34 M-Series - H2i® MXZ Outdoor Units (November 2014) © 2014 Mitsubishi Electric US, Inc. 9. CAPACITY CORRECTION TABLE BY REFRIGERANT PIPING LENGTH DUE TO CONTINUING RESEARCH AND PRODUCT IMPROVEMENT, SPECIFICATIONS AND DATA ARE STILL UNDER REVIEW Due to continuing improvement, above specification may be subject to change without notice. M-Series - H2i® MXZ Outdoor Units (November 2014) © 2014 Mitsubishi Electric US, Inc. H2i-MXZ-35 10. SOUND PRESSURE LEVELS MXZ-2C20NAHZ FAN SPEED FUNCTION SPL(dB(A)) High Cooling 54 High Heating 58 LINE MXZ-3C24NAHZ 70 NC-70 60 NC-60 50 NC-50 40 NC-40 30 NC-30 Cooling 54 High Heating 58 LINE 80 70 NC-60 50 NC-50 40 NC-40 30 NC-30 NC-20 125 250 500 1000 2000 4000 8000 NC-70 60 20 APPROXIMATE THRESHOLD OF HEARING FOR CONTINUOUS NOISE 63 OCTAVE BAND SOUND PRESSURE LEVEL, 0dB = 0.0002 MICRO BAR OCTAVE BAND SOUND PRESSURE LEVEL, 0dB = 0.0002 MICRO BAR 80 10 High 90 90 20 FAN SPEED FUNCTION SPL(dB(A)) 10 APPROXIMATE THRESHOLD OF HEARING FOR CONTINUOUS NOISE 63 NC-20 125 MXZ-3C30NAHZ 250 500 1000 2000 4000 8000 BAND CENTER FREQUENCIES, Hz BAND CENTER FREQUENCIES, Hz FAN SPEED FUNCTION SPL(dB(A)) High Cooling 54 High Heating 58 LINE OCTAVE BAND SOUND PRESSURE LEVEL, 0dB = 0.0002 MICRO BAR 90 80 70 NC-70 60 NC-60 50 NC-50 40 NC-40 30 NC-30 20 10 APPROXIMATE THRESHOLD OF HEARING FOR CONTINUOUS NOISE 63 NC-20 125 250 500 1000 2000 4000 8000 BAND CENTER FREQUENCIES, Hz OUTDOOR UNIT 39.4 in. MICROPHONE Test conditions Cooling: Dry-bulb temperature 95°F Wet-bulb temperature 75°F Heating: Dry-bulb temperature 45°F Wet-bulb temperature 43°F Due to continuing improvement, above specification may be subject to change without notice. H2i-MXZ-36 M-Series - H2i® MXZ Outdoor Units (November 2014) © 2014 Mitsubishi Electric US, Inc. 10. SOUND PRESSURE LEVELS MODE SPL(dB) COOLING 49 HEATING 53 LINE 90 80 70 NC-70 60 NC-60 50 NC-50 40 NC-40 30 NC-30 20 10 APPROXIMATE THRESHOLD OF HEARING FOR CONTINUOUS NOISE 63 125 NC-20 250 500 1000 2000 4000 8000 MXZ-5C42NAHZ MXZ-5C42NAHZ OCTAVE BAND SOUND PRESSURE LEVEL, dB (0 dB = 0.0002 µbar) OCTAVE BAND SOUND PRESSURE LEVEL, dB (0 dB = 0.0002 µbar) MXZ-4C36NAHZ MXZ-4C36NAHZ OCTAVE BAND SOUND PRESSURE LEVEL, dB (0 dB = 0.0002 µbar) LINE 90 80 70 NC-70 60 NC-60 50 NC-50 40 NC-40 30 NC-30 20 10 APPROXIMATE THRESHOLD OF HEARING FOR CONTINUOUS NOISE 63 125 NC-20 250 500 1000 2000 4000 8000 BAND CENTER FREQUENCIES, Hz BAND CENTER FREQUENCIES, Hz MXZ-8C48NA MXZ-8C48NAHZ MXZ-8C48NAHZ MODE SPL(dB) COOLING 50 HEATING 54 MODE SPL(dB) COOLING 51 HEATING 54 LINE 90 80 70 NC-70 MICROPHONE 1m(3.3ft) 60 UNIT NC-60 50 NC-50 1.5m (5ft) 40 NC-40 30 NC-30 20 10 APPROXIMATE THRESHOLD OF HEARING FOR CONTINUOUS NOISE 63 125 GROUND NC-20 250 500 1000 2000 4000 8000 BAND CENTER FREQUENCIES, Hz Due to continuing improvement, above specification may be subject to change without notice. M-Series - H2i® MXZ Outdoor Units (November 2014) © 2014 Mitsubishi Electric US, Inc. H2i-MXZ-37 11. STANDARD OPERATION RANGE MXZ-2C20NAHZMXZ-3C24NAHZMXZ-3C30NAHZ Model MXZ-2C20NAHZ Outdoor unit MXZ-3C24NAHZ MXZ-3C30NAHZ Rating 208/230 V 60 Hz 1 Guaranteed Voltage Min. 198 V 208 V 230 V Max. 253 V Due to continuing improvement, above specification may be subject to change without notice. H2i-MXZ-38 M-Series - H2i® MXZ Outdoor Units (November 2014) © 2014 Mitsubishi Electric US, Inc. 12. ACCESSORIES Part Number Descriptions Applicable model BV12FFSI2 Refrigeration Ball Valve-Flare/Schrader/Insulated - 1/2" size BV14FFSI2 Refrigeration Ball Valve-Flare/Schrader/Insulated - 1/4" size BV38FFSI2 Refrigeration Ball Valve-Flare/Schrader/Insulated - 3/8" size BV58FFSI2 Refrigeration Ball Valve-Flare/Schrader/Insulated - 5/8" size CWMB1 4 piece ( 1 pair) condensing unit wall mounting brackets painted steel DSD-400P Outdoor Unit 3-1/4 inch Mounting Base (Pair) - Plastic MSDD-50AR-E Flared Connections for connecting two branch boxes 4C36, 5C42, 8C48NAHZ and branch boxes All Models 4C36, 5C42, 8C48NAHZ MSDD-50BR-E Brazed Connections for connecting two branch boxes MAC-A454JP-E Port Adapter size: 3/8" X 1/2" MAC-A455JP-E Port Adapter size: 1/2" X 3/8" 2C20, 3C24, 3C30, 4C36, 5C42, 8C48NAHZ 3C24, 3C30, 4C36, 5C42, 8C48NAHZ MAC-A456JP-E Port Adapter size: 1/2" X 5/8" PAC-493PI Port Adapter size: 1/4" x 3/8" PAC-IF01MNT-E M-NET Adapter 3C30, 4C36, 5C42, 8C48NAHZ All Models ULTRILITE2 Condensing Unit Mounting Pad 24" x 42" x 3" Due to continuing improvement, above specification may be subject to change without notice. M-Series - H2i® MXZ Outdoor Units (November 2014) © 2014 Mitsubishi Electric US, Inc. H2i-MXZ-39 12. ACCESSORIES Part Number Descriptions PAC-MKA30BC Three Port Branch Box Applicable model 4C36, 5C42, 8C48NAHZ PAC-MKA50BC Five Port Branch Box PAC-SG76RJ 3/8” x 5/8” Port Adapter 3C30, 4C36, 5C42, 8C48NAHZ PAC-SG60DS-E Drain Socket 2C20, 3C24, 3C30NAHZ PAC-SH71DS-E Drain Socket 4C36, 5C42, 8C48NAHZ PAC-SH96SG-E Airflow Guide All Models Due to continuing improvement, above specification may be subject to change without notice. H2i-MXZ-40 M-Series - H2i® MXZ Outdoor Units (November 2014) © 2014 Mitsubishi Electric US, Inc.
© Copyright 2025 ExpyDoc