MWC series Features Specification Model Port size External dimension (mm) MWC-1000 MWC-4000 3/8 1 φ85×382 (※) Max. air flow φ130×501 1 MPa Max. operating pressure 940 NL/min Option 4,000 NL/min Bracket 1.6 kg Weight 4.3 kg ※ Pressure is at 0.7 MPa. Order example MODEL Order example of bracket PORT THREAD FLOW CODE 1000 4000 FLOW CODE 1000 4000 The pressure loss is less than 1%. Flow capacity vs. Air pressure Nl/ min Nl/ min Pressure loss / flow capacity 1200 Bracket Blank: Rc thread NPT: NPT thread G: G thread ※NPT, G: Using converting sockets (Attachment). 1000 800 5000 Flow capacity vs. Air pressure 4000 3000 600 2000 400 1000 200 0 0.1 0 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 MPa MPa Pressure loss vs. Flow capacity MPa MPa Pressure loss vs. Flow capacity 0.012 0.010 0.012 0.010 0.008 0.008 0.006 0.006 0.004 0.004 0.002 0.002 0 300 600 900 1200 1500 0 1000 2000 3000 4000 5000 6000 7000 Nl/ min ※ This product must be operated within the condition designated by blue areas in the graphs. Nl/ min MWC Four- step separation Compact and high efficiency Water drop Dust Air in Air out Oil mist M-EDDY filter Helical air path The M-EDDY filter which absorbs both mist and oil, has four times filtration capacity compared to the regular filters. It can supply clean air free of mist particles whose size is more than 1μm. The compressed air is Induced into the helical air path. Mesh coalescer The mesh coalescer removes large particles and lets them fall. The majority of impurities are removed at this stage. Anti - rolling up mechanism There is a built-in mechanism that keeps isolated impurities from coming back to the air flow. Next, centrifugal force removes small particles that have passed through the mesh coalescer. They are dropped into the bottom through the wall of the body and finally collected in the sump. Auto drain The accumulation of oil, sewage and other impurities in the bowl are automatically drain. Application examples MWC-4000 MWC-1000 Piping distance above 15m (※1) Compressor (※2) Piping distance above 15m Terminal equipment (※1) Compressor ※1. Should be installed as far as possible from the compressor. ※2. Should be installed as closer as possible to the terminal equipments. (※2) Terminal equipment MWC Proposal Usual air system 22 kW Compressor Main line filter 1. Air filter (Particle 5μm) 2. Regulator 3. Mist seperator (Oil 0.3μm) Refrigerating air dryer PUSH 1. Air filter (Particle 5μm) 2. Regulator 3. Mist seperator (Oil 0.3μm) 4. Micro mist seperator (Oil mist 0.01μm) Particle Water PUSH Cyclone dryer system Particle 1~3μm Water 1~3μm Oil 1~3μm 1. Cyclone dryer 2. Regulator 22 kW Compressor Particle 0.3μm Water 0.3μm Oil 0.3μm 1. Cyclone dryer 2. Regulator 3. Mist separator Particle 0.01μm Water 0.01μm Oil 0.01μm 1. Cyclone dryer 2. Regulator 3. Mist separator 4. Micor mist separator MWC Dimensions Dimensions Bracket (382) φ82 168 168 φ82 R1/8 G1 NPT1 (195) φ45 (123) φ25 G & NPT thread G3/8 NPT3/8 22 Using converting sockets 41 123.5 61 1.5 32 12 160 184 Installation diagram R1/8 φ11 24 15 218 120 74 φ80 Rc3/8 φ120 Rc1 (501) Air out Air in 105 125 90 Air out Air in 22 φ1 φ9 35 φ85 11 22.5 φ130 81 φ8 0 1.6 Rc thread
© Copyright 2024 ExpyDoc