INEX PARTYWALL NLB-162 ™ ANY BUILDING • ANY SURFACE • ANYWHERE STEEL FRAME: INEX>WALLBOARD12 FRL MIN –/60/60 & Rw+Ctr 55 NOV 2014 Page 1 INEX>WALLBOARD12 SYSTEM NLB-162 A SUPER HIGH IMPACT CEMENTITIOUS SHEET FOR STEEL FRAME LIGHTWEIGHT CONSTRUCTION INTERTENANCY & COMMON WALLS FRL –/60/60 Rw+Ctr = 55 2 x 64x50 0.75 BMT STEEL STUD FRAMES WITH 10mm GAP 8 GAUGE WING TEK SCREWS AT 200mm c/c; MIN CLASS 3 BACKING BOARD, IF JOINT REQUIRED (NO FIRE SEALANT REQUIRED) SINGLE SHEET OF 12mm THICK 3000x600 INEX>WALLBOARD12 (WITH RECESSED EDGES) OPTIONS FOR INSULATION (SEE TABLE PAGE 3) RECESSED EDGE: TAPED/SET JOINT (NO FIRE SEALANT REQUIRED) 162mm O/A WALL THICKNESS CAVITY SERVICES BOTH SIDES APPROVED (ELECTRICAL OR WATER SERVICES) RECESSED EDGE NON-LOAD BEARING / DISCONTINUOUS CONSTRUCTION CLASS 2, 3 OR 4 PART BUILDING, TYPE A CONSTRUCTION INTERTENANCY WALLS AND COMMON WALLS – CAVITY SERVICES BOTH SIDES UBIQ Pty Ltd, 1/17 Chester St, Annandale NSW 2038 Australia • ABN 14 146 086 142 • (02) 9519 4460 • [email protected] • www.ubiq.com.au INEX PARTYWALL NLB-162 ™ ANY BUILDING • ANY SURFACE • ANYWHERE 5 NOGGIN 4 x SCREWS AT EACH NOGGIN IF JOINT REQUIRED BACKING BOARD CUT FROM INEX>WALLBOARD12 AND EXTEND AS FAR AS STUD FACES (NO FIRE MASTIC REQUIRED) 100 MAX 600 2 MAX 600 3 3 4 162 1 150 VERTICAL JOINT (TYPICAL) NOV 2014 Page 2 1 SCREWS AT 200mm c/c AND OFFEST AT JOINTS EQEQ NOGGIN FIT SHEETS VERTICAL FLOOR TO SOFFIT 15 200 100 STEEL FRAME: INEX>WALLBOARD12 FRL MIN –/60/60 & Rw+Ctr 55 1 6 WALL THICKNESS 162mm 1 3000x600 INEX>WALLBOARD12 4 64x50 0.75 BMT STEEL STUD FRAME 2 RECESSED EDGE: TAPED/SET JOINT 5 8 GAUGE WING TEK SCREWS, MIN CLASS 3 3 OPTIONS FOR INSULATION 6 MIN 10mm GAP (WITH RECESSED EDGES) (NO FIRE SEALANT REQUIRED) (SEE TABLE PAGE 3) (BY STUDCO BUILDING SYSTEMS) NON-LOAD BEARING / DISCONTINUOUS CONSTRUCTION CLASS 2, 3 OR 4 PART BUILDING, TYPE A CONSTRUCTION INTERTENANCY WALLS AND COMMON WALLS – CAVITY SERVICES BOTH SIDES UBIQ Pty Ltd, 1/17 Chester St, Annandale NSW 2038 Australia • ABN 14 146 086 142 • (02) 9519 4460 • [email protected] • www.ubiq.com.au INEX>PARTYWALL TYPE NLB- NLB-162 INEX PARTYWALL 162 ™ STEEL FRAME: INEX>WALLBOARD12 FRL MIN -/60/60 & Rw+Ctr 55 ANY BUILDING • ANY SURFACE • ANYWHERE STEEL FRAME: INEX>WALLBOARD12 FRL MIN –/60/60 & Rw+Ctr 55 12 64 10 64 NOV 2014 Page 3 12 SOFFIT 20 64 x 50 TOP TRACK DEFELECTION HEAD FIXED AT Max. 600mm CENTRES 70 75 TOP OF SHEET 20mm CLEAR OF SOFFIT TROWELED ON BOSTIK 'FIREBAN ONE' POLYURETHANE SEALANT TOP FIXING TO STUD (DO NOT FIX THROUGH TRACK HEAD) TOP OF STUD 15mm CLEAR OF SOFFIT TOP NOGGIN TOP NOGGIN FIXING TO TOP NOGGIN AT CENTRE OF NOGGIN INEX>WALLBOARD12 ALL STEEL COMPONENTS MIN 0.75 BMT INEX>WALLBOARD12 64 x 32 BOTTOM TRACK FIXED AT Max. 600mm CENTRES 15 10 FIXING TO BOTTOM TRACK TROWELED ON BOSTIK 'FIREBAN ONE' POLYURETHANE SEALANT BASE INSULATION OPTIONS FRL Rw/Rw+Ctr Services (Rw) TYPE OF Acoustic Services INSULATION OPTIONFire Resistance Level Acoustic Airborne INSULATION 2 x 70mm 2 x 70mm R2.2R2.2 3 GLASS WOOL 24kg/m 24kg/m3 GLASS WOOL Exova F/R/L Test No. PKA Test No. PKA Test No. Rw/Rw + Ctr Predicted SPL –/60/6062/55 -/60/60 62/55 Exova-31526000TBC Kilargo-629WA Test AAAC 5 Star Rating TBC TBC of < 30dBA R1.5 2 x 70mm –/60/6062/55 1 x 145mm R3.0 -/60/60 62/55 3 GLASS WOOL 14kg/m Exova-31526000 PKA-141 Opinion 7kg/m3 GLASS WOOL TBC TBCPKA-141 OpinionTBC (SUCH AS KNAUF EARTHWOOL CEILING BATTS E2271) 1 x 145mm R3.0 –/60/6062/55 7kg/m3 GLASS WOOL Exova-31526000 PKA-141 Opinion UBIQ Pty Ltd, 1/17 Chester St, Annandale NSW 2038 Australia • ABN 14 146 086 142 • (02) 9519 4460 • [email protected] • www.ubiq.com.au INEX PARTYWALL NLB-162 ™ ANY BUILDING • ANY SURFACE • ANYWHERE STEEL FRAME: INEX>WALLBOARD12 FRL MIN –/60/60 & Rw+Ctr 55 WALL SYSTEM APARTMENT SIZE 82m2 SPACE GAIN 3m2 INTERTENANCY WALL MIN FRL –/60/60 MIN Rw+Ctr 55 NOV 2014 Page 4 EXTERNAL WALL MIN FRL –/60/60 TYPICAL AAC WALL SYSTEM THICKNESS (mm) 228230 INEX>WALLBOARD SYSTEM THICKNESS (mm) 170135 GAIN THE SPACE – SELL/RENT THE SPACE FOR A TYPICAL 80m2 TWO BEDROOM APARTMENT INEX>PARTY & INEX>EXTERNAL WALLS DELIVER AN ADDITIONAL 3.0m2 INTERNAL STRATA AREA (WHEN REPLACING TYPICAL INTERTENANCY AND COMMON WALLS AT 228mm THICK & TYPICAL EXTERNAL WALL AT 230mm THICK) UBIQ Pty Ltd, 1/17 Chester St, Annandale NSW 2038 Australia • ABN 14 146 086 142 • (02) 9519 4460 • [email protected] • www.ubiq.com.au
© Copyright 2024 ExpyDoc