Plan Elevation Section - Steel Construction New Zealand

General Note : Refer to Tables & Detailing Constants in SCNZ 14.2: 2007 “Structural Steelwork Connections Guide”, for plate, weld and bolt specifications not otherwise shown on this drawing
90
bif
45
sg
45
Plan
dif
10
ae6
tif
3 sides
tww
tiw
45
twf
biw
3 sides
Elevation
4
3
2
1
2/08
9/03
7/01
4/99
No. Date
spw
d
diw
npw
rows
a
3 sides
npf rows
twf
SCNZ - 14 : 2007 RE-ISSUE
R4 - 100 : 2003
ONLINE GUIDE
4D STEEL DETAILING R4-100-1999
Details
Revisions
Section
Structural Steelwork
Connections Guide SCNZ-14: 2007
Steel Construction
New Zealand Inc.
Bolted Welded Beam Splice
PO Box 76403, Manukau City, New Zealand
ph : +64-9-263-5635 fax : +64-9-263-5638
email : [email protected]
BWBS
Notes:
1. The number of bolt rows in the
flanges,n pf , and in the web,n pw,
varies.
2. The total number of flange
bolts = 4 n pf .
3. The total number of web
bolts = n pw.
4. This drawing shows BWBS
with n pf =2, n pw = 2, 8 flange
bolts and 2 web bolts.
Drawing No.
DRAWN
SCALE
NTS
BWBS
Rev.
4