Instrumentation & Control Panel Submittal Olympia Force Main Submittal # 14-7271-01A Nelson Lewis, Inc. December 2014 16310 Bratton Lane Building 1, Suite 100 Austin, TX 78728 Phone: (512) 863-3224 Fax: (512) 868-5446 www.controlpanelsusa.net CP USA Project # 14-7271 CP USA Project Manager: Brandon Friemel Submittal Clarification 14-7271-01A ATTN: Patrick N. Moseley, P.E. Engineer for Moeller & Associates c/o Mark Bray Nelson Lewis, Inc. PROJECT: DATE: Item # 1) Olympia Force Main Project December 11, 2014 Comment CP USA is submitting our Instrument Panel schematics without the Power Insulator shown on Contract Drawing Sheet E-006, as we are uncertain about the requirements for the Power Insulator for this application. CP USA would ask the engineer to provide more information in the form of a specification for the type of Power Insulator required. Regards, Brandon Friemel Project Manager 16310 Bratton Lane, Suite 100 * Austin, Texas 78728 * Phone: (512) 863-3224 * Fax: (512) 868-5446 * www.controlpanelsusa.net Nelson Lewis, Inc. December 2014 Olympia Force Main CP USA Submittal # 14-7271-01A SCHEDULE OF EQUIPMENT ITEM # 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 DESCRIPTION Instrument Panel Enclosure, NEMA 4, Carbon Steel, Free Standing, 3-Point Latching Back Panel, Full Folding Shelf LED Panel Light, Door Switch, 120VAC, 18" Circuit Breaker, UL489, 1-Pole, 5 Amp Circuit Breaker, UL489, 1-Pole,10 Amp Surge Suppressor, 120VAC 24VDC Power Supply, 5A UPS, 24VDC, 5A Universal DIN rail adapter Relay, 4PDT, 10A, 120VAC Relay, DPDT, 10A, 120VAC Relay, DPDT, 10A, 24VDC Relay Base, 2-pole Relay Base, 4-pole Push-To-Test Pilot Light, LED, Full Voltage, 30.5mm, NEMA 4/4X/13, 12-130V AC/DC, Amber Pushbutton, 30.5mm, NEMA 4/4X/13, Flush, Black Contact Block, 10Amp, 1 N.O. - 1 N.C. Alarm Horn, 120VAC, Nema 4X, with weather proof box Alarm Strobe Light, Red Lense, 120VAC, 1/2" conduit mount DC Signal Line Surge Protector, 4-20mA w/ Shield, 20 kA Max Discharge Current Terminal Block, Feed Through, Finger Safe, 2610awg, 41 Amp, 800Volt, Type UT4 Ground Terminal Block, Finger Safe, 26-10awg, 41 Amp, 800Volt, Type UT4-PE Ground Bus Bar Wire Way Prepared by Control Panels USA Inc. MANUFACTURER PART NUMBER Hoffman A72H3124FS3PT 1 each Hoffman Hoffman Saginaw Siemens Siemens Phoenix Contact Phoenix Contact Phoenix Contact Phoenix Contact Idec Idec Idec Idec Idec A72P30F1 ACSHELF1818SS SCE-LF18NO 5SJ4111-7HG40 5SJ4110-7HG40 2856812 2866734 2320254 2320089 RH4B-UL-AC120 RH2B-UL-AC120 RH2B-UL-DC24 SH2B-05 SH4B-05 1 1 1 2 1 1 1 1 2 7 15 5 20 7 each each each each each each each each each each each each each each Allen-Bradley 800H-QRTH2A 4 each Allen-Bradley 800H-AR2 2 each Allen-Bradley 800T-XA 2 each Federal Signal 350-120VAC-WB 1 each Federal Signal LP3P-Red 1 each Citel DLA-24D3 1 each Phoenix Contact 3044102 A/R each Phoenix Contact 3044128 A/R each Square D Thomas & Betts PK7GTA TY series A/R A/R each ft Page 1 of 1 QUANTITY UNIT 12/11/2014 Nelson Lewis, Inc. December 2014 Olympia Force Main CP USA Submittal # 14-7271-01A SCHEDULE OF EQUIPMENT ITEM # DESCRIPTION 26 Field Instruments Combustible Gas Detector N/A N/A N/A N/A N/A N/A N/A Existing/Owner Provided Field Instruments & Equipment Low Level Lockout Float Switch, N.C. Contacts High Level Float Switch, N.O. Contacts High High Level Float Switch, N.O. Contacts Auto-Dialer Radio Unit Pump Controller Submersible Level Transmitter Prepared by Control Panels USA Inc. MANUFACTURER PART NUMBER QUANTITY UNIT ATI C12-17-0100-2-1-00-0261 1 each Unknown Unknown Unknown Unknown Unknown Unknown Unknown Unknown Unknown Unknown Unknown Unknown Unknown Unknown 1 1 1 1 1 1 1 each each each each each each each Page 1 of 1 12/11/2014 Nelson Lewis, Inc. November 2014 Olympia Force Main CP USA Submittal # 14-7271-01A SCHEDULE OF EQUIPMENT ITEM # 7 8 11 12 13 14 15 21 DESCRIPTION Spare Equipment Surge Suppressor, 120VAC 24VDC Power Supply, 5A Relay, 4PDT, 10A, 120VAC Relay, DPDT, 10A, 120VAC Relay, DPDT, 10A, 24VDC Relay Base, 2-pole Relay Base, 4-pole DC Signal Line Surge Protector, 4-20mA w/ Shield, 20 kA Max Discharge Current Prepared by Control Panels USA Inc. MANUFACTURER PART NUMBER QUANTITY UNIT Phoenix Contact Phoenix Contact Idec Idec Idec Idec Idec 2856812 2866734 RH4B-ULAC120 RH2B-UL-AC120 RH2B-UL-DC24 SH2B-05 SH4B-05 2 2 5 5 1 6 5 each each each each each each each Citel DLA-24D3 3 each Page 1 of 1 12/11/2014 Item # 01 Free-Stand Enclosures Type 4 Free-Stand Enclosures and Accessories Mild Steel Free-Stand Enclosures Type 4 Free-Stand Enclosures and Accessories Spec-00156 F 763.422.2211 763.422.2600 Free-Stand with 3-Point Latch, Type 4 APPLICATION These enclosures are ideal for mounting equipment on panels or racks in indoor or outdoor applications where it is necessary to protect controls and instrumentation from wet, non-corrosive environments. The design features Hoffman’s exclusive POWERGLIDE™ Handle with 3-point latching for secure closure. FEATURES • • • • • -point latch for security and ease of use 3 Mounting channels accommodate panel or rack-mount equipment P anels and rack mount angles can be mounted anywhere along channels Rolled flange around door opening excludes liquids and contaminants L ifting eyes for easy handling SPECIFICATIONS • • • • • • • • • • 2 gauge steel 1 3-point latch system with POWERGLIDE® handle S eams continuously welded and ground smooth; no holes or knockouts Mounting channels welded horizontally to interior body sides at top, bottom and center Heavy-gauge continuous hinge with stainless steel hinge pin Data pocket is high-impact thermoplastic L ifting eyes Oil-resistant door gasket Bonding provision on door Provision for mounting fluorescent light FINISH ANSI 61 gray polyester powder paint inside and out over pretreated surfaces. Optional panels have either a white or a conductive finish. ACCESSORIES INDUSTRY STANDARDS UL 508A Listed; Type 4, 12; File No. E61997 cUL Listed per CSA C22.2 No. 94; Type 4, 12; File No. E61997 NEMA Type 3, 4, 12, 13 E.I.A. RS310D IEC 60529, IP66 See also Accessories. Drawers INTERSAFE™ Data Interface Ports, Type 4/4X/12 PANELITE™ Enclosure Lights Overview Pull-Out Shelves Rack Mounting Angles - U Style (Type RA) Swing-Out Panels for Free-Stand Type 4, 4X and 12 Enclosures with Mounting Channel MODIFICATION AND CUSTOMIZATION Hoffman excels at modifying and customizing products to your specifications. Contact your local Hoffman sales office or distributor for complete information. Bulletin: A4L3 Standard Product Catalog Number A72H2518FS3PT A72H3124FS3PT A72H3724FS3PT 1 Mild Steel AxBxC in./mm 72.06 x 25.06 x 18.06 1830 x 637 x 459 72.06 x 31.06 x 24.06 1830 x 789 x 611 72.06 x 37.06 x 24.06 1830 x 941 x 611 SUBJECT TO CHANGE WITHOUT NOTICE Rack Units 35 35 35 EQUIPMENT PROTECTION SOLUTIONS Spec-00156 F Free-Stand Enclosures Type 4 Free-Stand Enclosures and Accessories EQUIPMENT PROTECTION SOLUTIONS Spec-00156 F PH 763.422.2211 • FAX 763.422.2600 • HOFFMANONLINE.COM Mild Steel 2 Item # 02 Panels and Panel Accessories Panels for Enclosures Panels for Free-Stand Type 4, 4X and 12 Single- and Dual-Access One-Door Enclosures with Mounting Channel Panels for one-door, single-access and one-door, dual-access Free-Stand Type 12 Enclosures, Free-Stand Type 4 Enclosures and OneDoor Type 4X Free-Stand Fiberglass Enclosures. Panels are 12 gauge steel and can be positioned anywhere along horizontal mounting channels (see dimension drawing Sections B-B for limitations). Half-length panels can be located in the upper or lower portion of the enclosure. Panels are finished with white polyester powder paint or a conductive, corrosion-resistant coating and furnished with plated mounting hardware. Bulletin: PNL30, PNLFS Catalog Number A60P24F1 A60P24F1G A60P24F2 A60P24F2G A72P24F1 A72P24F1G A72P24F2 A72P24F2G A90P24F1 A90P24F1G A90P24F2 A90P24F2G A72P30F1 A72P30F1G A72P30F2 A72P30F2G A60P36F1 A60P36F1G A60P36F2 A60P36F2G A72P36F1 A72P36F1G A72P36F2 A72P36F2G A90P36F1 A90P36F1G A90P36F2 A90P36F2G Description Full Panel Full Panel Half Panel Half Panel Full Panel Full Panel Half Panel Half Panel Full Panel Full Panel Half Panel Half Panel Full Panel Full Panel Half Panel Half Panel Full Panel Full Panel Half Panel Half Panel Full Panel Full Panel Half Panel Half Panel Full Panel Full Panel Half Panel Half Panel Finish Painted steel Conductive Painted steel Conductive Painted steel Conductive Painted steel Conductive Painted steel Conductive Painted steel Conductive Painted steel Conductive Painted steel Conductive Painted steel Conductive Painted steel Conductive Painted steel Conductive Painted steel Conductive Painted steel Conductive Painted steel Conductive Panel Size (in.) 48.00 x 20.00 48.00 x 20.00 24.88 x 20.00 24.88 x 20.00 60.00 x 20.00 60.00 x 20.00 30.88 x 20.00 30.88 x 20.00 78.00 x 20.00 78.00 x 20.00 39.88 x 20.00 39.88 x 20.00 60.00 x 26.00 60.00 x 26.00 30.88 x 26.00 30.88 x 26.00 48.00 x 32.00 48.00 x 32.00 24.88 x 32.00 24.88 x 32.00 60.00 x 32.00 60.00 x 32.00 30.88 x 32.00 30.88 x 32.00 78.00 x 32.00 78.00 x 32.00 39.88 x 32.00 39.88 x 32.00 Panel Size (mm) 1218 x 508 1218 x 508 632 x 508 632 x 508 1524 x 508 1524 x 508 784 x 508 784 x 508 1981 x 508 1981 x 508 1013 x 508 1013 x 508 1524 x 660 1524 x 660 784 x 660 784 x 660 1219 x 813 1219 x 813 632 x 813 632 x 813 1524 x 813 1524 x 813 784 x 813 784 x 813 1981 x 813 1981 x 813 1013 x 813 1013 x 813 Fits Enclosure A x B (in.) 60.00 x 24.00 60.00 x 24.00 60.00 x 24.00 60.00 x 24.00 72.00 x 24.00 72.00 x 24.00 72.00 x 24.00 72.00 x 24.00 90.00 x 24.00 90.00 x 24.00 90.00 x 24.00 90.00 x 24.00 72.00 x 30.00 72.00 x 30.00 72.00 x 30.00 72.00 x 30.00 60.00 x 36.00 60.00 x 36.00 60.00 x 36.00 60.00 x 36.00 72.00 x 36.00 72.00 x 36.00 72.00 x 36.00 72.00 x 36.00 90.00 x 36.00 90.00 x 36.00 90.00 x 36.00 90.00 x 36.00 Fits Enclosure A x B (mm) 1524 x 610 1524 x 610 1524 x 610 1524 x 610 1829 x 610 1829 x 610 1829 x 610 1829 x 610 2286 x 610 2286 x 610 2286 x 610 2286 x 610 1829 x 762 1829 x 762 1829 x 762 1829 x 762 1524 x 914 1524 x 914 1524 x 914 1524 x 914 1829 x 914 1829 x 914 1829 x 914 1829 x 914 2286 x 914 2286 x 914 2286 x 914 2286 x 914 Use combinations of panels for 3-5 door A 28 enclosures. 11 Accessories SUBJECT TO CHANGE WITHOUT NOTICE EQUIPMENT PROTECTION Spec-00310 P Item # 03 Shelves, Keyboard Trays and Gland Plates Folding Shelves Accessories Shelves, Keyboard Trays and Gland Plates Folding Shelves Spec-00035 N63.422.2211 7 763.422.2600 Stainless Steel Folding Shelf Catalog Number ACSHELF12 ACSHELF1212SS ACSHELF1818SS ACSHELF2424SS Size AxB in./mm 12.00 x 12.00 305 x 305 12.00 x 12.00 305 x 305 18.00 x 18.00 457 x 457 24.00 x 24.00 610 x 610 Maximum Distributed Load Rating (lb.) 150 Maximum Distributed Load Rating (kg) 68 150 68 150 68 150 68 Supports instruments and test equipment used to install and maintain electrical components in an enclosure. Also ideally suited for supporting laptop computers, monitoring units and other equipment used with programmable controllers. The shelf can be installed on the inside or outside surface of larger Hoffman industrial enclosures (except PROLINE™ ). Automatically locks in the horizontal position when raised. When not in use, the shelf folds down and projects only 1 in. (25 mm) from the mounting surface. Constructed of 304 stainless steel with a brushed finish. Maintains UL/CSA Type 4, 4X and 12 rating when properly installed on a Hoffman enclosure. Bulletin: A80 Large Folding Shelf Catalog Number AASHLF1218 AA61SHLF1218 AA35SHLF1218 AASHLF1818 AA61SHLF1818 Supports instruments and test equipment used to install and maintain electrical components in an enclosure. Also ideally suited for supporting laptop computers, monitoring units and other equipment used with programmable controllers. The shelf can be installed on the inside or outside surface of larger Hoffman industrial enclosures (except PROLINE™ ). Automatically locks in the horizontal position when raised. When not in use, the shelf folds to 1.73 in. (44 mm) from the mounting surface. All parts are heavy gauge steel. Maintains UL/CSA Type 4 and 12 when properly intalled on a Hoffman enclosure. Bulletin: A34Y, A80 1 Accessories AA35SHLF1818 AASHLF2424 AA61SHLF2424 AA35SHLF2424 Size AxB in./mm 18.00 x 12.00 457 x 305 18.00 x 12.00 457 x 305 18.00 x 12.00 457 x 305 18.00 x 18.00 457 x 457 18.00 x 18.00 457 x 457 18.00 x 18.00 457 x 457 24.00 x 24.00 610 x 610 24.00 x 24.00 610 x 610 24.00 x 24.00 610 x 610 Maximum Distributed Load Rating (lb.) 150 Maximum Distributed Load Rating (kg) 68 Finish White 150 68 Gray 150 68 Light gray 150 68 White 150 68 Gray 150 68 Light gray 150 68 White 150 68 Gray 150 68 Light gray Catalog numbers ACSHELF12 and ACSHELF18 have been obsoleted. Please use the shelves above as replacements. SUBJECT TO CHANGE WITHOUT NOTICE EQUIPMENT PROTECTION Spec-00035 N Item # 04 300 SAGINAW CONTROL & ENGINEERING • STOCK PRICE LIST GENERAL ACCESSORIES LED Light Fixture Application - LED light fixture is designed to provide interior lighting for an enclosure. Can be mounted to light channels in the top of an enclosure or on the front flange of most enclosures. Door activated adjustable switch, switch can be removed and relocated. Terminal block on each end of fixture, making it easy to wire and daisy chain multiple lights continuously. LED bulb with PVC frosted white protective light diffuser included. Housing made from steel and powder coated white epoxy polyester. Units with convenience receptacle outlet are 120 VAC with ground 50/60 HZ. Without convenience receptacle outlet 100 to 277 VAC 50/60 HZ. Catalog No. Height Width Depth Product List (A) (B) (C)AMPVACHz Code Price SCE-LF18 2.75 18.18 4.00 0.53 100-125 50/60 P2 206.55 SCE-LF24 2.75 24.18 4.00 0.53 100-125 50/60 P2 218.03 2.75 18.18 4.00 0.53 100-240 50/60 P2 185.90 2.75 24.18 4.00 0.53 100-240 50/60 P2 196.72 Product Code List Price SCE-LF18NO SCE-LF24NO No (Outlet ) No (Outlet ) Construction - • 4000K Frosted White • 18 inch 850 Lumens • 24 inch 900 Lumens IS10 - Industry Standards UL Component Recognized Light Switch Mounting Bracket Catalog No. SCE-LSMB Height Width Depth (A)(B) (C) 2.00 2.68 1.00 P2 25.56 9 General Accessories Designed to remote mount the door activated light switch when space is limited. Light Switch Mounting Bracket may be used with SCE-LF18, SCE-LF18NO, SCE-LF24 & SCE-LF24NO. For installation information, consult our Installation Manual at www. saginawcontrol.com. Full Light Switch Assembly Designed to remote mount the light switch when space is limited. Catalog No. SCE-LSA Product List CodePrice P2 Phone (989) 799-6871 Fax (989) 799-4524 38.34 Item # 05, 06 Product Selection – 5SJ41..-.HG40 Type HSJ: Interrupting rating: 240 VAC: 14,000 Maximum RMS Symmetrical Amps 60 VDC: 10,000 Amps Type NSJ: Interrupting rating: 240 VAC: 10,000 Maximum RMS Symmetrical Amps 60 VDC (1-pole) / 125 VDC (2- & 3-pole): 10,000 Amps TYPE No. of In (A) Poles 1 0.3 1 0.5 1 1 1 1.6 1 2 1 3 1 4 1 5 1 6 1 8 1 10 1 13 1 15 1 16 1 20 1 25 1 30 1 32 1 35 1 40 1 45 1 50 1 60 1 63 HSJ Characteristic B Order No. ----------------5SJ4106-6HG40 --5SJ4110-6HG40 5SJ4113-6HG40 5SJ4118-6HG40 5SJ4116-6HG40 5SJ4120-6HG40 5SJ4125-6HG40 5SJ4130-6HG40 5SJ4132-6HG40 5SJ4135-6HG40 5SJ4140-6HG40 5SJ4145-6HG40 5SJ4150-6HG40 5SJ4160-6HG40 5SJ4163-6HG40 5SJ4...-.HG4. Product Profile 090121.doc HSJ Characteristic C Order No. 5SJ4114-7HG40 5SJ4105-7HG40 5SJ4101-7HG40 5SJ4115-7HG40 5SJ4102-7HG40 5SJ4103-7HG40 5SJ4104-7HG40 5SJ4111-7HG40 5SJ4106-7HG40 5SJ4108-7HG40 5SJ4110-7HG40 5SJ4113-7HG40 5SJ4118-7HG40 5SJ4116-7HG40 5SJ4120-7HG40 5SJ4125-7HG40 5SJ4130-7HG40 5SJ4132-7HG40 5SJ4135-7HG40 5SJ4140-7HG40 NSJ Characteristic C Order No. HSJ Characteristic D Order No. 5SJ4114-8HG40 5SJ4105-8HG40 5SJ4101-8HG40 5SJ4115-8HG40 5SJ4102-8HG40 5SJ4103-8HG40 5SJ4104-8HG40 5SJ4111-8HG40 5SJ4106-8HG40 5SJ4108-8HG40 5SJ4110-8HG40 5SJ4113-8HG40 5SJ4118-8HG40 5SJ4116-8HG40 5SJ4120-8HG40 5SJ4125-8HG40 5SJ4130-8HG40 5SJ4132-8HG40 5SJ4135-8HG40 5SJ4140-8HG40 5SJ4145-8HG40 5SJ4150-8HG40 5SJ4160-8HG40 5SJ4163-8HG40 5SJ4145-7HG40 5SJ4150-7HG40 5SJ4160-7HG40 5SJ4163-7HG40 6 of 19 NSJ Characteristic D Order No. January 2009 Product Selection – 5SJ4…-.HG41 Type HSJ: Interrupting rating: 240 VAC: 14 kA Maximum RMS Symmetrical 60 VDC (1-pole) / 125 VDC (2- & 3-pole): 10kA Type NSJ: Interrupting rating: 240 VAC: 10kA Maximum RMS Symmetrical 60 VDC (1-pole)/125 VDC (2- & 3-pole): 10 kA HSJ TYPE No. of In Characteristic C (A) Order No. Poles * 0.3 5SJ4*14-7HG41 * 0.5 5SJ4*05-7HG41 * 1 5SJ4*01-7HG41 * 1.6 5SJ4*15-7HG41 * 2 5SJ4*02-7HG41 * 3 5SJ4*03-7HG41 * 4 5SJ4*04-7HG41 * 5 5SJ4*11-7HG41 * 6 5SJ4*06-7HG41 * 8 5SJ4*08-7HG41 * 10 5SJ4*10-7HG41 * 13 5SJ4*13-7HG41 * 15 5SJ4*18-7HG41 * 16 5SJ4*16-7HG41 * 20 5SJ4*20-7HG41 * 25 5SJ4*25-7HG41 * 30 5SJ4*30-7HG41 * 32 5SJ4*32-7HG41 * 35 5SJ4*35-7HG41 * 40 5SJ4*40-7HG41 * 45 * 50 * 60 * 63 1Substitute the “*” with: 1 for 1-pole mCBs 2 for 2-pole mCBs 3 for 3-pole mCBs 5SJ4...-.HG4. Product Profile 090121.doc NSJ Characteristic C Order No. 5SJ4*45-7HG41 5SJ4*50-7HG41 5SJ4*60-7HG41 5SJ4*63-7HG41 7 of 19 HSJ Characteristic D Order No. 5SJ4*14-8HG41 5SJ4*05-8HG41 5SJ4*01-8HG41 5SJ4*15-8HG41 5SJ4*02-8HG41 5SJ4*03-8HG41 5SJ4*04-8HG41 5SJ4*11-8HG41 5SJ4*06-8HG41 5SJ4*08-8HG41 5SJ4*10-8HG41 5SJ4*13-8HG41 5SJ4*18-8HG41 5SJ4*16-8HG41 5SJ4*20-8HG41 NSJ Characteristic D Order No. 5SJ4*25-8HG41 5SJ4*30-8HG41 5SJ4*32-8HG41 5SJ4*35-8HG41 5SJ4*40-8HG41 5SJ4*45-8HG41 5SJ4*50-8HG41 5SJ4*60-8HG41 5SJ4*63-8HG41 January 2009 Product Selection – 5SJ4…-.HG42 Type NSJ: Interrupting rating: 480Y/277 VAC 10,000 Maximum RMS Symmetrical Amps 60 VDC (1-pole) / 125 VDC (2- & 3-pole) 10,000 Amps HSJ TYPE No. of In Characteristic C (A) Order No. Poles * 0.3 --* 0.5 --* 1 --* 1.6 --* 2 --* 3 --* 4 --* 5 --* 6 --* 8 --* 10 --* 13 --* 15 --* 16 --* 20 --* 25 --* 30 --* 32 --* 35 --* 40 --* 45 --* 50 --* 60 --* 63 --1Substitute the “*” with: 1 for 1-pole mCBs 2 for 2-pole mCBs 3 for 3-pole mCBs 5SJ4...-.HG4. Product Profile 090121.doc NSJ Characteristic C Order No. 5SJ4*14-7HG42 5SJ4*05-7HG42 5SJ4*01-7HG42 5SJ4*15-7HG42 5SJ4*02-7HG42 5SJ4*03-7HG42 5SJ4*04-7HG42 5SJ4*11-7HG42 5SJ4*06-7HG42 5SJ4*08-7HG42 5SJ4*10-7HG42 5SJ4*13-7HG42 5SJ4*18-7HG42 5SJ4*16-7HG42 5SJ4*20-7HG42 5SJ4*25-7HG42 5SJ4*30-7HG42 5SJ4*32-7HG42 5SJ4*35-7HG42 5SJ4*40-7HG42 --------- 8 of 19 HSJ Characteristic D Order No. ------------------------------------------------- NSJ Characteristic D Order No. 5SJ4*14-8HG42 5SJ4*05-8HG42 5SJ4*01-8HG42 5SJ4*15-8HG42 5SJ4*02-8HG42 5SJ4*03-8HG42 5SJ4*04-8HG42 5SJ4*11-8HG42 5SJ4*06-8HG42 5SJ4*08-8HG42 5SJ4*10-8HG42 5SJ4*13-8HG42 5SJ4*18-8HG42 5SJ4*16-8HG42 5SJ4*20-8HG42 5SJ4*25-8HG42 5SJ4*30-8HG42 5SJ4*32-8HG42 ------------- January 2009 Control Circuit Protection Supplementary Protectors Dimensions 5SX2 supplementary protectors 5SX2, 5SY4, 5SY5 supplementary protectors 5SJ4, single pole branch circuit protector 5SX9 auxiliary switch, 5SX9 fault signal Additional component for 5SX2; can be retrofitted 5SX9 1.., 5SX9 2.. 5ST3 auxiliary switch 5ST3 fault signal contact can be retrofitted to 5SY4, 5SY5, 5SP4 5SP4 supplementary protectors 5ST3 shunt trip 5ST3 undervoltage release can be retrofitted to 5SY4, 5SY5, 5SP4 Siemens Energy & Automation, Inc. Industrial Controls Catalog 16/23 Control Circuit Protection General Data 5SJ4 Branch Circuit Protector Technical Data Specification Tripping characteristic Number of poles Rated voltage (UL 489) Operating voltage, min. Rated current Interrupting Rating (UL 489) AC: Max. RMS Symmetrical Standards Certifications Degree of protection Device depth Mounting technique Terminals Terminal tightening torque Wire Size Recommended Wire Strip Length Mounting Position Ambient temperature Calibration temperature Storage temperature Resistance to vibration Dimensions Siemens Energy & Automation, Inc. Industrial Controls Catalog 5SJ41 Mini-Breaker C D 1 V AC: 240 max. V DC: 60 max. 24 VAC/DC 6 to 63 A 0.3 to 63 A 0.3 to 63 A V AC 240: 14 kA V AC 240: 14 kA (0.3 - 40 A) (0.3 - 20 A) V AC 240: 5 kA V AC 240: 5 kA (45 - 63 A) (25 - 63 A) V AC 240: 14 kA; V DC 60: 10 kA V DC 60: 10 kA V DC 60: 10 kA (0.3 - 63 A) (0.3 - 63 A) UL 489, CSA 22.2 No. 5-02, IEC/EN 60 898 UL, cUL, File No. E 243414 IP 10 acc. to DIN EN 60 529; IP 40 when panel mounted 70 mm Standard 35 mm DIN rail Identical screw terminals on both line and load sides 31 lbs. in. (3.5 Nm) 14-4 AWG (1.5 - 25 mm2) 60/75˚C, Cu only 0.59 in. (15 mm) B As Required -13˚ to +113˚F (-25˚ to +45˚C) temporary: +131˚F (+55˚C); max. humidity: 95% 25˚C (77˚F) acc. to UL 489 30˚C (86˚F) acc. to EN 60 898 -40˚ to +167˚F (-40˚ to +75˚C) 60 m/s2 at 10 Hz up to 150 Hz acc. to IEC 60 068-2-6 see catalog page 16/23 16/5 Control Circuit Protection General Data Trip characteristics Tripping characteristics acc. to EN 60 898 Tripping characteristic B, -6 Type B characteristic designed for European residential circuit protection. This characteristic can also be used for protection of computers and electronic equipment. Magnetic trip point - 3 to 5 times In rating. Thermal trip point - 1.13 to 1.45 protector rating. Tripping characteristic C, -7 Type C characteristic is for general device protection in control circuits. Magnetic trip point - 5 to10 times In rating. Thermal trip point - 1.13 to 1.45 protector rating. Tripping characteristic D, -8 Type D characteristic is designed for high inrush loads. Magnetic trip point - 10 to 20 times In rating. Thermal trip point - 1.13 to 1.45 protector rating. 1,13 1,45 120 A I2_06353c 20 10 6 4 1,13 1,45 120 2 1 40 20 2 20 2 Seconds Seconds 10 6 4 10 6 4 1 0,6 0,4 2 1 0,6 0,4 0,2 0,2 0,1 0,06 0,04 0,1 0,06 0,04 0,02 For different ambient temperatures, the current values of the delayed tripping operation change by approximately 5% per 10°K temperature difference. Specifically they increase for temperatures below 25°C (5SJ41), 30°C (5SP, 5SX, 5SY) and decrease for temperatures above 25°C (5SJ41), 30°C (5SP, 5SX, 5SY). 20 1 40 10 6 4 0,01 A I2_06354c 60 40 Tripping time Tripping time Minutes 60 40 Minutes Tripping characteristic A, -5 Type A characteristic is designed to protect very sensitive circuits such as semiconductors. Magnetic trip point - 2 to 3 times In rating. Thermal trip point - 1.13 to 1.45 protector rating. 0,02 1 1,5 2 3 4 5 6 8 10 15 20 Multiple of rated current 0,01 1 30 If more that one electrical circuit is loaded in a series of miniature circuit breakers or supplementary protectors, the resulting increase in ambient temperature affects the characteristic curve. In this case an additional correction factor found in the following table must be used. 1,5 2 3 4 5 6 8 10 15 20 Multiple of rated current Number 1 2-3 4-6 >7 Correction factor K 1.00 0.90 0.88 0.85 30 For DC voltages the maximum current values of the instantaneous tripping operation increase by a factor of 1.2. 16/2 Siemens Energy & Automation, Inc. Industrial Controls Catalog Item # 07 https://www.phoenixcontact.com/us/products/2856812 Type 3 surge protection device - PT 2-PE/S-120AC/FM - 2856812 Please be informed that the data shown in this PDF Document is generated from our Online Catalog. Please find the complete data in the user's documentation. Our General Terms of Use for Downloads are valid (http://phoenixcontact.com/download) Pluggable type 3 arrester (device protection) for single-phase power supply networks with separate N and PE (3conductor system: L1, N, PE) with remote indication contact. The figure shows the PT 2-PE/ S-230AC/FM version Product Features Plugs can be checked with CHECKMASTER Tool-free plug replacement With floating remote indication contact Consists of base element and plug Optical signaling of disconnection via LED DIN rail module For single and multi-phase power supply units Key commercial data Packing unit 1 pc Weight per Piece (excluding packing) 79.5 GRM Custom tariff number 85363010 Country of origin Germany Technical data Dimensions Height 90 mm Width 17.7 mm Depth 65.5 mm Horizontal pitch 1 Div. 12/11/2014 Page 1 / 5 https://www.phoenixcontact.com/us/products/2856812 Type 3 surge protection device - PT 2-PE/S-120AC/FM - 2856812 Technical data Dimensions Complete module height 90 mm Complete module width 17.7 mm Complete module depth 65.5 mm Ambient conditions Degree of protection IP20 Ambient temperature (operation) -40 °C ... 85 °C General Housing material PA Inflammability class according to UL 94 V0 Color black Standards for air and creepage distances DIN VDE 0110-1 IEC 60664-1 DIN VDE 0675-6 IEC 61643-1 Surge voltage category III Pollution degree 2 Type DIN rail module, two-section, divisible Mounting type DIN rail: 35 mm Arrester can be tested with CHECKMASTER from software version: From SW rev. 1.00 Direction of action 1L-N & N-PE Protective circuit IEC test classification III EN type T3 Nominal voltage UN 120 V AC Arrester rated voltage UC 150 V AC Nominal frequency fN 50 Hz 60 Hz Nominal current IN 26 A (30 °C) Operating effective current IC at UC ≤ 1.1 mA Standby power consumption PC ≤ 200 mVA Residual current IPE ≤ 1.5 µA Nominal discharge current In (8/20) µs 2.5 kA 3 kA (in acc. with UL 1449) Combination wave UOC 6 kV Voltage protection level Up (L-N) ≤ 620 V 12/11/2014 Page 2 / 5 https://www.phoenixcontact.com/us/products/2856812 Type 3 surge protection device - PT 2-PE/S-120AC/FM - 2856812 Technical data Protective circuit Voltage protection level Up (L-PE) ≤ 850 V Voltage protection level Up (N-PE) ≤ 850 V Response time tA (L-N) ≤ 25 ns Response time tA (L-PE) ≤ 100 ns Max. required back-up fuse 25 A (gL/C) Surge protection fault message Optical, remote indicator contact Non-heating apparatus connection, power supply Connection method Screw connection Connection type IN Screw terminal blocks Connection type OUT Screw terminal blocks Screw thread M3 Tightening torque 0.8 Nm Stripping length 8 mm Conductor cross section stranded min. 0.2 mm² Conductor cross section stranded max. 2.5 mm² Conductor cross section solid min. 0.2 mm² Conductor cross section solid max. 4 mm² Conductor cross section AWG/kcmil min. 24 Conductor cross section AWG/kcmil max 12 Remote indicator contact Connection name Remote fault indicator contact Switching function N/C contact Connection method Screw connection Screw thread M3 Tightening torque 0.8 Nm Stripping length 8 mm Conductor cross section stranded min. 0.2 mm² Conductor cross section stranded max. 2.5 mm² Conductor cross section solid min. 0.2 mm² Conductor cross section solid max. 4 mm² Conductor cross section AWG/kcmil min. 24 Conductor cross section AWG/kcmil max 12 Maximum operating voltage Umax. AC 250 V Maximum operating voltage Umax DC 50 V Max. operating current Imax 3 A AC Standards and Regulations 12/11/2014 Page 3 / 5 https://www.phoenixcontact.com/us/products/2856812 Type 3 surge protection device - PT 2-PE/S-120AC/FM - 2856812 Technical data Standards and Regulations Standards/specifications IEC 61643-1 2005 EN 61643-11/A11 2007 UL 1449 NF C61-740 Classifications eCl@ss eCl@ss 4.0 27140201 eCl@ss 4.1 27130801 eCl@ss 5.0 27130801 eCl@ss 5.1 27130801 eCl@ss 6.0 27130806 eCl@ss 7.0 27130806 ETIM ETIM 2.0 EC000942 ETIM 3.0 EC000942 ETIM 4.0 EC000942 ETIM 5.0 EC001473 UNSPSC UNSPSC 6.01 30212010 UNSPSC 7.0901 39121610 UNSPSC 11 39121610 UNSPSC 12.01 39121610 UNSPSC 13.2 39121620 Drawings 12/11/2014 Page 4 / 5 https://www.phoenixcontact.com/us/products/2856812 Type 3 surge protection device - PT 2-PE/S-120AC/FM - 2856812 Dimensioned drawing Circuit diagram 90 L 5 6 L 44,8 11 J 12 OUT 51,5 65,5 IN N N 1 2 PE 3 4 PE Phoenix Contact 2014 © - all rights reserved http://www.phoenixcontact.com 12/11/2014 Page 5 / 5 Item # 08 https://www.phoenixcontact.com/us/products/2866734 Power supply unit - QUINT-PS/ 3AC/24DC/ 5 - 2866734 Please be informed that the data shown in this PDF Document is generated from our Online Catalog. Please find the complete data in the user's documentation. Our General Terms of Use for Downloads are valid (http://phoenixcontact.com/download) Primary-switched QUINT POWER power supply for DIN rail mounting with SFB (Selective Fuse Breaking) Technology, input: 3-phase, output: 24 V DC/5 A Product description QUINT POWER power supplies with maximum functionality QUINT POWER circuit breakers magnetically and therefore quickly trip at six times the nominal current, for selective and therefore cost-effective system protection. The high level of system availability is additionally ensured, thanks to preventive function monitoring, as it reports critical operating states before errors occur. Reliable starting of heavy loads takes place via the static power reserve POWER BOOST. Thanks to the adjustable voltage, all ranges between 5 V DC ... 56 V DC are covered. Product Features High level of system availability even in the event of permanent phase failure Reliable starting of difficult loads Preventive function monitoring Key commercial data Packing unit 1 pc Weight per Piece (excluding packing) 1038.0 GRM Custom tariff number 85044030 Country of origin Thailand Technical data Dimensions Width 40 mm Height 130 mm Depth 125 mm Width with alternative assembly 122 mm Height with alternative assembly 130 mm Depth with alternative assembly 43 mm 12/11/2014 Page 1 / 6 https://www.phoenixcontact.com/us/products/2866734 Power supply unit - QUINT-PS/ 3AC/24DC/ 5 - 2866734 Technical data Ambient conditions Degree of protection IP20 Ambient temperature (operation) -25 °C ... 70 °C (> 60 °C derating, 2.5 %/K, startup at -40°C type-tested) Ambient temperature (storage/transport) -40 °C ... 85 °C Max. permissible relative humidity (operation) ≤ 95 % (at 25 °C, non-condensing) Noise immunity EN 61000-6-2:2005 Input data Nominal input voltage range 3x 400 V AC ... 500 V AC Input voltage range 3x 320 V AC ... 575 V AC 2x 360 V AC ... 575 V AC 450 V DC ... 800 V DC AC frequency range 45 Hz ... 65 Hz Frequency range DC 0 Hz Current consumption 3x 0.8 A (400 V AC) 3x 0.7 A (500 V AC) Inrush surge current < 15 A (typical) Power failure bypass > 20 ms (400 V AC) > 30 ms (500 V AC) Choice of suitable fuses 6 A ... 16 A (AC: Characteristics B, C, D, K) Type of protection Transient surge protection Protective circuit/component Varistor, gas-filled surge arrester Output data Nominal output voltage 24 V DC ±1 % Setting range of the output voltage 18 V DC ... 29.5 V DC (> 24 V constant capacity) Output current 5 A (-25°C ... 60°C, UOUT = 24 V DC) 7.5 A (with POWER BOOST, -25°C ... 40°C permanently, UOUT = 24 V DC) 30 A (SFB technology, 12 ms) Derating 60 °C ... 70 °C (2.5%/K) Connection in parallel Yes, for redundancy and increased capacity Connection in series Yes Residual ripple < 20 mVPP (with nominal values) Peak switching voltages nominal load < 20 mVPP (at nominal values, 20 MHz) Maximum power dissipation NO-Load 4W Power loss nominal load max. 14 W General Net weight 0.7 kg Operating voltage display Green LED 12/11/2014 Page 2 / 6 https://www.phoenixcontact.com/us/products/2866734 Power supply unit - QUINT-PS/ 3AC/24DC/ 5 - 2866734 Technical data General Efficiency > 89 % (at 400 V AC and nominal values) Insulation voltage input/output 4 kV AC (type test) 2 kV AC (routine test) Protection class I > 635000 h (40°C) Mounting position horizontal DIN rail NS 35, EN 60715 Assembly instructions Alignable: 5 mm horizontally, 15 mm next to active components, 50 mm vertically Electromagnetic compatibility Conformance with EMC Directive 2004/108/EC Low Voltage Directive Conformance with LV directive 2006/95/EC Standard – Electrical equipment of machines EN 60204 Standard - Electrical safety IEC 60950-1/VDE 0805 (SELV) Shipbuilding approval Germanischer Lloyd (EMC 2), ABS, LR, RINA, NK, DNV, BV Standard – Electronic equipment for use in electrical power installations and their assembly into electrical power installations EN 50178/VDE 0160 (PELV) Standard – Safety extra-low voltage IEC 60950-1 (SELV) and EN 60204 (PELV) Standard - Safe isolation DIN VDE 0100-410 DIN VDE 0106-1010 Standard – Protection against electric shock DIN 57100-410 Standard – Protection against shock currents, basic requirements for protective separation in electrical equipment DIN VDE 0106-101 Standard – Limitation of mains harmonic currents EN 61000-3-2 Standard - Equipment safety GS (tested safety) Approval - requirement of the semiconductor industry with regard to mains SEMI F47-0706 Compliance Certificate voltage dips Information technology equipment - safety (CB scheme) CB Scheme UL approvals UL Listed UL 508 UL/C-UL Recognized UL 60950-1 (3-wire + PE, star net) UL ANSI/ISA-12.12.01 Class I, Division 2, Groups A, B, C, D (Hazardous Location) Surge voltage category III Connection data, input Connection method Pluggable screw connection Conductor cross section solid min. 0.2 mm² Conductor cross section solid max. 2.5 mm² Conductor cross section stranded min. 0.2 mm² Conductor cross section stranded max. 2.5 mm² Conductor cross section AWG/kcmil min. 20 12/11/2014 Page 3 / 6 https://www.phoenixcontact.com/us/products/2866734 Power supply unit - QUINT-PS/ 3AC/24DC/ 5 - 2866734 Technical data Connection data, input Conductor cross section AWG/kcmil max 12 Stripping length 7 mm Screw thread M3 Connection data, output Connection method Pluggable screw connection Conductor cross section solid min. 0.2 mm² Conductor cross section solid max. 2.5 mm² Conductor cross section stranded min. 0.2 mm² Conductor cross section stranded max. 2.5 mm² Conductor cross section AWG/kcmil min. 20 Conductor cross section AWG/kcmil max 12 Stripping length 7 mm Signaling Output name DC OK active Output description UOUT > 0.9 x UN: High signal Maximum switching voltage + 24 V DC Output voltage + 24 V DC Maximum inrush current min. 20 mA (short-circuit resistant) Continuous load current ≤ 20 mA Status display UOUT > 0.9 x UN: "DC OK" LED green Note on status display UOUT < 0.9 x UN: Flashing "DC OK" LED Conductor cross section solid min. 0.2 mm² Conductor cross section solid max. 2.5 mm² Conductor cross section stranded min. 0.2 mm² Conductor cross section stranded max. 2.5 mm² Conductor cross section AWG/kcmil min. 20 Conductor cross section AWG/kcmil max 12 Tightening torque, min 0.5 Nm Tightening torque max 0.6 Nm Screw thread M3 Output name DC OK floating Output description Relay contact, UOUT > 0.9 x UN: Contact closed Maximum switching voltage ≤ 30 V AC/DC Maximum inrush current ≤1A Continuous load current ≤1A Status display UOUT > 0.9 x UN: "DC OK" LED green 12/11/2014 Page 4 / 6 https://www.phoenixcontact.com/us/products/2866734 Power supply unit - QUINT-PS/ 3AC/24DC/ 5 - 2866734 Technical data Signaling Note on status display UOUT < 0.9 x UN: Flashing "DC OK" LED Output name POWER BOOST, active Output description IOUT < IN: High signal Maximum switching voltage + 24 V DC Output voltage + 24 V DC Maximum inrush current min. 20 mA (short-circuit resistant) Continuous load current ≤ 20 mA Status display IOUT > IN: LED "BOOST" yellow Classifications eCl@ss eCl@ss 4.0 27040702 eCl@ss 4.1 27040702 eCl@ss 5.0 27049002 eCl@ss 5.1 27049002 eCl@ss 6.0 27049002 eCl@ss 7.0 27049002 eCl@ss 8.0 27049002 ETIM ETIM 2.0 EC001039 ETIM 3.0 EC001039 ETIM 4.0 EC000599 ETIM 5.0 EC002540 UNSPSC UNSPSC 6.01 30211502 UNSPSC 7.0901 39121004 UNSPSC 11 39121004 UNSPSC 12.01 39121004 UNSPSC 13.2 39121004 Drawings 12/11/2014 Page 5 / 6 https://www.phoenixcontact.com/us/products/2866734 Power supply unit - QUINT-PS/ 3AC/24DC/ 5 - 2866734 Block diagram L1 (+) L2 L3 (-) DC OK I < IN 13 14 Phoenix Contact 2014 © - all rights reserved http://www.phoenixcontact.com 12/11/2014 Page 6 / 6 Item # 09 https://www.phoenixcontact.com/us/products/2320254 Uninterruptible power supply - QUINT-UPS/ 24DC/ 24DC/ 5/1.3AH - 2320254 Please be informed that the data shown in this PDF Document is generated from our Online Catalog. Please find the complete data in the user's documentation. Our General Terms of Use for Downloads are valid (http://phoenixcontact.com/download) Uninterruptible power supply with IQ technology and integrated power storage for DIN rail mounting, input 24 V DC, output: 24 V DC/5 A, power storage: lead AGM 1.3 Ah, incl. mounted UTA 107/30 universal DIN rail adapter Product Features Easy handling thanks to automatic battery detection, tool-free battery replacement during operation, and communication via the IFS interface Reliable starting of difficult loads with the static POWER BOOST power reserve with up to 1.5 times the nominal current permanently Fast tripping of standard circuit breakers with SFB (selective fuse breaking) technology Device suitable for universal use thanks to comprehensive license package and extensive parameterization and diagnostics options Key commercial data Packing unit 1 pc Weight per Piece (excluding packing) 2420.0 GRM Custom tariff number 85371091 Country of origin China Technical data Dimensions Width 88 mm Height 138 mm Depth 125 mm Ambient conditions Degree of protection IP20 Ambient temperature (operation) 0 °C ... 40 °C Ambient temperature (storage/transport) -15 °C ... 40 °C Max. permissible relative humidity (operation) ≤ 95 % (25°C, non-condensing) 12/11/2014 Page 1 / 5 https://www.phoenixcontact.com/us/products/2320254 Uninterruptible power supply - QUINT-UPS/ 24DC/ 24DC/ 5/1.3AH - 2320254 Technical data Ambient conditions Noise immunity EN 61000-6-2:2005 Input data Nominal input voltage 24 V DC Input voltage range 18 V DC ... 30 V DC Current consumption 9.3 A (24 V DC) 9.7 mA 1.7 A 7A Buffer period 50 min (1 A) 5 min (5 A) Output data Nominal output voltage 24 V DC Output voltage range 18 V DC ... 30 V DC Output current 5 A (-25 °C ... 60 °C) Derating 60 °C ... 70 °C (2.5%/K) Connection in series No Output fuse 1x 15 A General IQ technology Yes Disposal Used batteries must not be thrown away with household waste, they should instead be disposed of in accordance with applicable national regulations. They can also be returned to Phoenix Contact or the manufacturer. Net weight 2.2 kg Memory medium Lead rechargeable battery module 1.3 Ah Efficiency > 97.1 % (Mains operation, with charged power storage) 97.31 % Protection class III > 806000 h (40°C) Mounting position horizontal DIN rail NS 35, EN 60715 Assembly instructions Can be aligned: horizontal 5 mm, vertical 50 mm Electromagnetic compatibility Conformance with EMC Directive 2004/108/EC Standard - Electrical safety EN 60950-1/VDE 0805 (SELV) EN 61558-2-17 Standard – Electronic equipment for use in electrical power installations and their assembly into electrical power installations EN 50178/VDE 0160 (PELV) 12/11/2014 Page 2 / 5 https://www.phoenixcontact.com/us/products/2320254 Uninterruptible power supply - QUINT-UPS/ 24DC/ 24DC/ 5/1.3AH - 2320254 Technical data General UL approvals UL/C-UL Recognized UL 60950 UL Listed UL 508 Connection data, input Connection method Pluggable screw connection Conductor cross section solid min. 0.2 mm² Conductor cross section solid max. 2.5 mm² Conductor cross section stranded min. 0.2 mm² Conductor cross section stranded max. 2.5 mm² Conductor cross section AWG/kcmil min. 20 Conductor cross section AWG/kcmil max 12 Stripping length 7 mm Screw thread M4 Connection data, output Connection method Pluggable screw connection Conductor cross section solid min. 0.2 mm² Conductor cross section solid max. 2.5 mm² Conductor cross section stranded min. 0.2 mm² Conductor cross section stranded max. 2.5 mm² Conductor cross section AWG/kcmil min. 20 Conductor cross section AWG/kcmil max 12 Stripping length 7 mm Signaling Signalization designation Power In OK Status display LED Note on status display Static to Conductor cross section solid min. 0.2 mm² Conductor cross section solid max. 2.5 mm² Conductor cross section stranded min. 0.2 mm² Conductor cross section stranded max. 2.5 mm² Conductor cross section AWG/kcmil min. 24 Conductor cross section AWG/kcmil max 12 Tightening torque, min 0.5 Nm Tightening torque max 0.6 Nm Screw thread M4 Signalization designation Alarm 12/11/2014 Page 3 / 5 https://www.phoenixcontact.com/us/products/2320254 Uninterruptible power supply - QUINT-UPS/ 24DC/ 24DC/ 5/1.3AH - 2320254 Technical data Signaling Output name Switching output Output description Relay Output voltage ≤ 30 V AC/DC Continuous load current ≤ 100 mA Status display LED Note on status display Static to Signalization designation Battery charge Output name Switching output Output description Relay Output voltage ≤ 30 V AC/DC Continuous load current ≤ 100 mA Status display LED bar graph Note on status display dynamic Signalization designation Battery mode Output name Switching output Output description Relay Type of signaling Battery mode Output voltage ≤ 30 V AC/DC Continuous load current ≤ 100 mA Status display LED Note on status display Static to Classifications eCl@ss eCl@ss 4.0 27040702 eCl@ss 4.1 27040702 eCl@ss 5.0 27242213 eCl@ss 5.1 27040603 eCl@ss 6.0 27040603 eCl@ss 7.0 27040603 eCl@ss 8.0 27049201 ETIM ETIM 3.0 EC001039 ETIM 4.0 EC000382 12/11/2014 Page 4 / 5 https://www.phoenixcontact.com/us/products/2320254 Uninterruptible power supply - QUINT-UPS/ 24DC/ 24DC/ 5/1.3AH - 2320254 Classifications ETIM ETIM 5.0 EC000382 UNSPSC UNSPSC 6.01 30211510 UNSPSC 7.0901 39121011 UNSPSC 11 39121011 UNSPSC 12.01 39121011 UNSPSC 13.2 39121011 Drawings Block diagram Input DC 24V Output DC 24V Data-Port 13 Confirm 14 23 mC tmax[min] I < IN Battery DC 24V J J 24 33 34 R1 24V 0.2A Alarm Bat.Mode Bat.Charge Remote R2 Phoenix Contact 2014 © - all rights reserved http://www.phoenixcontact.com 12/11/2014 Page 5 / 5 Item # 10 https://www.phoenixcontact.com/us/products/2320089 Assembly adapters - UTA 107/30 - 2320089 Please be informed that the data shown in this PDF Document is generated from our Online Catalog. Please find the complete data in the user's documentation. Our General Terms of Use for Downloads are valid (http://phoenixcontact.com/download) Universal DIN rail adapter Key commercial data Packing unit 1 pc Weight per Piece (excluding packing) 77.0 GRM Custom tariff number 79070000 Country of origin Thailand Technical data Dimensions Width 30 mm Height 107 mm Depth 9.6 mm General Housing material Steel Classifications eCl@ss eCl@ss 4.0 27040801 eCl@ss 4.1 27040801 eCl@ss 5.0 27049090 eCl@ss 5.1 27049090 eCl@ss 6.0 27049090 eCl@ss 7.0 27049090 eCl@ss 8.0 27049290 12/11/2014 Page 1 / 2 https://www.phoenixcontact.com/us/products/2320089 Assembly adapters - UTA 107/30 - 2320089 Classifications ETIM ETIM 3.0 EC001039 ETIM 4.0 EC001597 ETIM 5.0 EC002625 UNSPSC UNSPSC 6.01 30211502 UNSPSC 7.0901 39121004 UNSPSC 11 39121004 UNSPSC 12.01 39121004 UNSPSC 13.2 39121004 Phoenix Contact 2014 © - all rights reserved http://www.phoenixcontact.com 12/11/2014 Page 2 / 2 Item # 11, 12, 13, 14, 15 Relays Selection Guide Selection Guides General Purpose Relays RU Series RR Series RH Series RM Series RY Series Appearance Page E-3 E-10 E-16 E-19 2, 4 Form C 1, 2, 3 Form C 1, 2, 3, 4 Form C 2 Form C 2, 4 Form C Contact Rating (resistive) DPDT: 10A, 30V DC 10A, 250V AC 4PDT: 6A, 30V DC 6A, 250V AC 10A, 30V DC 10A, 120V, 240V AC 1/3HP, 240V AC 1/4HP, 120V AC 10A, 30V DC 10A, 120V, 240V AC 1/3HP, 240V AC 1/6HP, 120V AC 5A, 30V DC 5A, 120V AC, 240V AC DPDT: 3A, 30V DC; 3A, 120V AC, 240V AC 4PDT: 5A, 30V DC; 5A, 120V AC, 240V AC Silver Silver-cadmium oxide Silver DPDT E E-6 Contact Configuration Contact Material 4PDT AuSnOIn (silver tin oxide indium) AuAg/Ag (goldsilver alloy on silver) General Purpose Latching Relays RR2KP Series Standard Silver, gold-plated Bifurcated Silver-paladium alloy (Ag-PD Alloy) RH2L Series RY2KS Series RY2L Series E-26 E-29 E-32 Appearance Page Contact Configuration E-23 2 Form C 2 Form C 2 Form C 2 Form C Contact Rating (resistive) 10A, 30V DC 10A, 120V AC 10A, 30V DC 7.5A, 240V AC 10A, 120V AC 3A, 30V DC 3A, 120V AC 3A, 30V DC 3A, 120V AC 3A, 240V AC Contact Material Silver Silver-cadmium oxide Silver, gold-plated Silver, gold-flashed Solid State Relays RSS Series Appearance Page E-35 Contact Configuration 1 Form A (SPST-NO) Contact Rating 10, 25, 50, 75, 90A 48V AC to 660V AC Output Ratings Output Dual SCR (zero crossing) E-2 www.idec.com USA: (800) 262-IDEC or (408) 747-0550, Canada (888) 317-IDEC Relays RH Series RH Series — General Purpose Midget Relays Key features of the RH series include: • Compact midget size saves space • High switching capacity (10A) • Choice of blade or PCB style terminals • Relay options include indicator light, check button, and top mounting bracket • DIN rail, surface, panel, and PCB type sockets available for a wide range of mounting applications Specifications E E-10 Contact Material Silver cadmium oxide Contact Resistance 50mΩ maximum (initial value) Minimum Applicable Load 24V DC/30mA, 5V DC/100mA (reference value) Operating Time SPDT (RH1), DPDT (RH2): 20ms maximum 3PDT (RH3), 4PDT (RH4): 25ms maximum Release Time SPDT (RH1), DPDT (RH2): 20ms maximum 3PDT (RH3), 4PDT (RH4): 25ms maximum Maximum Continuous Applied Voltage (AC/DC) at 20°C 110% of the rated voltage Minimum Operating Voltage (AC/DC) at 20°C 80% of the rated voltage Drop-Out Voltage (AC) 30% or more of the rated voltage Drop-Out Voltage (DC) 10% or more of the rated voltage Power Consumption SPDT (RH1): DC: 0.8W AC: 1.1VA (50Hz), 1VA (60Hz) DPDT (RH2): DC: 0.9W AC: 1.4VA (50Hz), 1.2VA (60Hz) 3PDT (RH3): DC: 1.5W AC: 2VA (50Hz), 1.7VA (60Hz) 4PDT (RH4): DC: 1.5W AC: 2.5VA (50Hz), 2VA (60Hz) Insulation Resistance UL Recognized Files No. E67770 E59804 CSA Certified File No.LR35144 File No. BL951113332319 Ordering Information Order standard voltages for fastest delivery. Allow extra delivery time for non-standard voltages. Basic Part No. RH2B-U Coil Voltage: – AC110-120V 100MΩ min (measured with a 500V DC megger) SPDT (RH1) Between live and dead parts: 2,000V AC, 1 minute; Between contact circuit and operating coil: 2,000V AC, 1 minute; Between contacts of the same pole: 1,000V AC, 1 minute Dielectric Strength DPDT (RH2), 3PDT (RH3), 4PDT (RH4) Between live and dead parts: 2,000V AC, 1 minute; Between contact circuit and operating coil: 2,000V AC, 1 minute; Between contact circuits: 2,000V AC, 1 minute; Between contacts of the same pole: 1,000V AC, 1 minute Frequency Response 1,800 operations/hour Temperature Rise Coil: 85°C maximum Contact: 65°C maximum Vibration Resistance 0 to 6G (55Hz maximum) Shock Resistance SPDT/DPDT: 200N (approximately 20G) 3PDT/4PDT: 100N (approximately 10G) Life Expectancy Electrical: over 500,000 operations at 120V AC, 10A; (over 200,000 operations at 120V AC, 10A for SPDT [RH1], 3PDT [RH3], 4PDT [RH4]) Mechanical: 50,000,000 operations Operating Temperature –30 to +70°C Weight SPDT: 24g, DPDT: 37g (approximately) 3PDT: 50g, 4PDT: 74g (approximately) www.idec.com USA: (800) 262-IDEC or (408) 747-0550, Canada (888) 317-IDEC Relays RH Series Part Numbers Part Numbers: RH Series with Options Termination B (blade) V2 (PCB 0.078" [2mm] wide) Contact Configuration Indicator Light Check Button Indicator Light and Check Button Top Bracket SPDT Basic Part No. RH1B-U RH1B-L* — — RH1B-UT DPDT RH2B-U RH2B-UL RH2B-UC RH2B-ULC RH2B-UT 3PDT RH3B-U RH3B-UL RH3B-UC RH3B-ULC RH3B-UT 4PDT RH4B-U RH4B-UL RH4B-UC RH4B-ULC RH4B-UT SPDT RH1V2-U RH1V2-L* — — — DPDT RH2V2-U RH2V2-UL RH2V2-UC RH2V2-ULC — 3PDT RH3V2-U RH3V2-UL RH3V2-UC RH3V2-ULC — 4PDT RH4V2-U RH4V2-UL RH4V2-UC RH4V2-ULC — * RH1B(V2)-L is not UL recognized. Ratings E Coil Ratings Rated Current ±15% at 20°C Rated Voltage AC 6V 12V 24V 120V* 240V† DC 6V 12V 24V 48V 110V‡ 60Hz Coil Resistance ±15% at 20°C 50Hz SPDT DPDT 3PDT 4PDT SPDT DPDT 3PDT 4PDT SPDT DPDT 3PDT 150mA 75mA 37mA 7.5mA 3.2mA 200mA 100mA 50mA 11mA 5.5mA 280mA 140mA 70mA 14.2mA 7.1mA 330mA 165mA 83mA 16.5mA 8.3mA 170mA 86mA 42mA 8.6mA 3.7mA 238mA 118mA 59.7mA 12.9mA 6.5mA 330mA 165mA 81mA 16.4mA 8.2mA 387mA 196mA 98mA 19.5mA 9.8mA 18.8Ω 76.8Ω 300Ω 7,680Ω 3,1200Ω 9.4Ω 39.3Ω 153Ω 4,170Ω 15,210Ω 6.0Ω 25.3Ω 103Ω 2770Ω 12,100Ω 4PDT 5.4Ω 21.2Ω 84.5Ω 2220Ω 9120Ω SPDT DPDT 3PDT 4PDT SPDT DPDT 3PDT 4PDT 128mA 64mA 32mA 18mA 8mA 150mA 75mA 36.9mA 18.5mA 9.1mA 240mA 120mA 60mA 30mA 12.8mA 250mA 125mA 62mA 31mA 15mA 47Ω 188Ω 750Ω 2,660Ω 13,800Ω 40Ω 160Ω 650Ω 2,600Ω 12,100Ω 25Ω 100Ω 400Ω 1,600Ω 8,600Ω 24Ω 96Ω 388Ω 1550Ω 7,340Ω * For RH2 relays = 110/120V AC. † For RH2 relays = 220/240V AC. ‡ For RH2 relays = 100/110V DC. AC 6V 12V 24V 120V* 240V† DC 6V 12V 24V 48V 110V‡ Coil Inductance Coil Inrush Rated Voltage SPDT DPDT 3PDT 4PDT SPDT 250mA 120mA 56mA 12mA 7mA 340mA 170mA 85mA 16mA 8mA 520mA 260mA 130mA 26mA 12mA 620mA 310mA 165mA 33mA 16mA 0.09H 0.037H 1.5H 37H 130H Energizing DPDT 3PDT 0.08H 0.30H 1.2H 33H 130H 0.05H 0.22H 0.9H 21H 84H 4PDT 0.05H 0.18H 0.73H 18H 73H SPDT 0.06H 0.22H 0.9H 22H 77H De-Energizing DPDT 3PDT 0.04H 0.16H 0.63H 15H 62H 0.03H 0.12H 0.5H 12H 47H 4PDT 0.02H 0.10H 0.36H 9H 36H SPDT DPDT 3PDT 4PDT SPDT DPDT 3PDT 4PDT N/A N/A N/A N/A N/A N/A N/A N/A * For RH2 relays = 110/120V AC. † For RH2 relays = 220/240V AC. ‡ For RH2 relays = 100/110V DC. www.idec.com USA: (800) 262-IDEC or (408) 747-0550, Canada (888) 317-IDEC E-11 Relays RH Series Ratings con’t Contact Ratings SPDT Resistive DPDT 3PDT 4PDT SPDT Inductive DPDT 3PDT 4PDT Motor Load SPDT DPDT 3PDT 10A 10A 10A 7.5A — 7.5A — — — — — — — — — Voltage Rating 28V DC UL 30V DC UL CSA Nominal 10A Nominal 0.5A 110V DC UL CSA Nominal UL CSA Nominal 120V AC 240V AC 10A — 10A 10A 0.5A 10A 10A 10A 0.5A 0.5A 10A 10A 7A 7A 7.5A 0.3A 7.5A 0.3A — 7.5A 7A 10A 10A — 7.5A 7A 7A 7A 7.5A 7.5A 4.5A 5A 5A — — — 7.5A 7.5A — — — 0.3A 0.3A — — — 1/6 1/6 1/6 — — — 1/3 1/3 1/3 — — — — 7.5A 7.5A * 7A 5A 5A 1. * 6.5A/pole, 20A total. 2. Inductive load cos ø = 0.3, L/R = 7ms. E Applicable Sockets Part Numbers: Sockets Standard DIN Finger-Safe DIN Surface Mount Rail Mount Rail Mount Relay Panel Mount — RH1B SH1B-05 RH2B SH2B-05 RH3B SH3B-05 SH1B-05C SH1B-51 SH2B-05C SH2B-02 SH3B-05C SH1B-62 SH2B-51 SH2B-62 SH3B-51 SH3B-62 — RH4B SH4B-05 SH4B-05C Spring & Clips (optional) PCB Mount SH4B-51 SH4B-62 Part Number Use With SY2S-02F1 SFA-101 SFA-202 SH1B-05, 05C SY4S-51F1 SFA-301 SFA-302 SH1B-51, 62 SY4S-02F1 SFA-101 SFA-202 SH2B-05, 05C SY4S-51F1 SFA-301 SFA-302 SH2B-51, 62 SH3B-05F1 SFA-101, -202 SH3B-05, 05C SY4S-51F1 SFA-301 SFA-302 SH3B-51, 62 SH4B-02F1 SFA-101, -202 SH4B-05, 05C SY4S-51F1 SFA-301 SFA-302 SH4B-51, 62 See Section F for details on sockets. All DIN rail mount sockets shown above can be mounted using DIN rail BNDN1000. Internal Circuits 1 1 4 1 2 4 1 2 3 5 5 8 5 6 8 5 6 7 4 8 9 9 12 9 10 12 9 10 11 12 13 14 13 14 13 14 13 14 (-) (+) (-) (+) (-) (+) (-) (+) RH1 E-12 RH2 www.idec.com RH3 RH4 USA: (800) 262-IDEC or (408) 747-0550, Canada (888) 317-IDEC Relays RH Series Electrical Life Curves RH1 1000 1000 AC 110V Resistive 500 Life (x 10,000) Operations Life (x 10,000) Operations 500 100 50 DC 30V Resistive 100 50 DC 100V Resistive DC 30V Inductive 20 20 AC 220V Inductive AC 110V Inductive 10 1 2 3 4 5 6 Load Current (A) AC 220V Resistive 7 8 9 DC 100V Inductive 10 10 1 2 3 AC 220V Resistive 4 5 6 7 8 9 10 Load Current (A) E RH2 1000 1000 AC 110V Resistive DC 30V Resistive 500 Life (x 10,000) Operations Life (x 10,000) Operations 500 100 50 50 AC 220V Resistive AC 110V Inductive AC 220V Inductive DC 30V Inductive DC 100V Resistive DC 100V Inductive 20 20 10 100 1 2 3 4 5 6 7 Load Current (A) 8 9 10 10 1 2 3 4 5 6 7 Load Current (A) 8 9 10 8 9 10 RH3 and 4 1000 1000 AC 110V Resistive 100 50 20 DC 30V Inductive 100 50 20 AC 220V Inductive AC 220V Resistive AC 110V Inductive 10 DC 30V Resistive 500 Life (x 10,000) Operations Life (x 10,000) Operations 500 1 2 www.idec.com 3 4 5 6 7 Load Current (A) 8 9 10 DC 100V Resistive DC 100V Inductive 10 1 2 3 4 5 6 7 Load Current (A) USA: (800) 262-IDEC or (408) 747-0550, Canada (888) 317-IDEC E-13 Relays RH Series Dimensions Top Bracket Mounting Blade Terminal RH1B-UT 0.39" RH2B-UT (10mm) 0.183" (4.7mm) Ø 0.101" (2.6mm) 0.257" 0.566" (14.5mm) 1.39" (35.6mm) or Less 0.183" (2mm) (3.5mm) 0.211" (5.4mm) 0.25" 0.839" (21.5mm) 1.39" (35.6mm) or Less 1.07" (27.5mm) 1.48" (38mm) 0.293" (7.5mm) (4.7mm) 0.137" 0.25" (6.4mm) (6.4mm) Plug-in Blade Terminal RH1B RH2B Total length from panel surface including socket: SH1B-05: 2.40" (61.5mm) maximum; SH1B-51: 1.54" (39mm) maximum Total length from panel surface including hold-down spring: SH1B-05: 2.48" (63.5mm) maximum; SH1B-51: 1.62" (41.6mm) maximum E (5.9mm) 0.078" (2mm) (3.5mm) 0.23" (6.6mm) 0.078" 0.137" (4.7mm) (0.5mm) 1.68" (43.2mm) 0.23" (5.9mm) 0.185" 0.019" 1.07" (27.5mm) (4.7mm) (0.5mm) 1.48" (38mm) 1.68" (43.2mm) 0.019" Ø 0.101" (2.6mm) 0.185" Total length from panel surface including socket: SH2B-05: 2.40" (61.5mm) maximum; SH2B-51: 1.54" (39.6mm) Total length from panel surface including hold-down spring: SH2B-05: 2.48" (63.5mm) maximum; SH2B-51: 1.62" (41.6mm) 0.183" (4.7mm) (0.5mm) 0.211" (5.4mm) 1.39" (35.6mm) or less 0.019" (0.5mm) 1.07" (27.5mm) 0.019" 0.25" 0.183" (4.7mm) 0.819" (21mm) 0.546" (6.4mm) 1.07" (27.5mm) Ø 0.101" (2.6mm) Ø 0.101" (2.6mm) (14mm) Plug-in Blade Terminal RH3B Total length from panel surface including socket: SH3B-05: 2.57" (66mm) maximum Total length from panel surface including hold-down spring: SH3B-05: 2.65" (68mm) maximum 1.39" (35.6mm) 0.25" or less (6.4mm) RH4B Total length from panel surface including socket: SH4B-05: 2.40" (61.5mm) or less; SH4B-51: 1.54" (39.6mm) Total length from panel surface including hold-down spring: SH4B-05: 2.48" (63.5mm) or less; SH4B-51: 1.62" (41.6mm) 0.183" 0.183" (4.7mm) (4.7mm) 1.39" (35.6mm) or Less Ø 0.101" (2.6mm) 0.019" (0.5mm) 1.21" (31mm) 0.25" (6.4mm) 1.39" (35.6mm) or less E-14 www.idec.com 1.07" (27.5mm) 0.25" (6.4mm) 1.07" (27.5mm) Ø 0.101" (2.6mm) 0.019" (0.5mm) 1.60" (41mm) USA: (800) 262-IDEC or (408) 747-0550, Canada (888) 317-IDEC Item # 16 Bulletin 800T/H 30.5 mm Push Buttons Pilot Lights Pilot Light Devices1 0 Transformer Type Pilot Light Cat. No. 800T-P16R Push-to-Test Pilot Light Cat. No. 800T-PT16R 1 Type 2 Lamp Type Volts Operator Only Full Voltage‡ Color Incandescent 24V AC/DC No Lamp 0…250V AC/DC LED 12…130 V AC/DC Universal‡ 3 Incandescent 4 120V AC, 50/60 Hz Transformer‡ LED No Lamp 5 Type 4/13 Pilot Light Push-to-Test1 Cat. No. Cat. No. 800T-SB00XX 800T-S00 800T-Q24R 800T-QT24R 800T-Q24G 800T-QT24G 800T-Q24A 800T-QT24A 800T-QN25 800T-QTN25 800T-QH2R 800T-QTH2R 800T-QH2G 800T-QTH2G 800T-QH2A 800T-QTH2A 800T-P16R 800T-PT16R 800T-P16G 800T-PT16G 800T-P16A 800T-PT16A 800T-PH16R 800T-PTH16R 800T-PH16G 800T-PTH16G 800T-PH16A 800T-PTH16A 800T-PN16 800T-PTN16 Red Green Amber No Lens Red Green Amber Red Green Amber Red Green Amber No Lens 1 Includes one standard Cat. No. 800T-XA (1 N.O. - 1 N.C.) contact block. For typical pilot light wiring diagrams, see page 10-65. Operator only supplied without power module, lamp, lens cap, or contact blocks. ‡ All pilot lights except push-to-test without sealed contacts and dual input transformer relay, are rated for Class 1, Division 2 applications. 6 (Push-to-Test) 800 T a 7 8 9 – P T c d b Code T H Protection Rating Description Metal, Type 4/13 Plastic, Type 4/4X/13 b Code Blank C Finger-Safe Guards Description No guards Guards on terminals Power Module Type 800T Type 4/13 Code P 11 Q Description Transformer (or dual input) Full voltage/ Universal e 16 G f g d a c 10 800H Type 4/4X/13 Code AR h f Lamp Test Options Code Description Blank No test option T Push-to-test D Dual input — diode♣ Dual input — transformer DT relay Note: Push-to-test supplied with factory jumpered contact block. e Illumination Options Code Description Blank Incandescent H LED1 PR QR Voltage Transformer Code Description 16 120V AC 50/60 Hz 26 240V AC 50/60 Hz 46 480V AC 50/60 Hz 56 600V AC 50/60 Hz Full Voltage — Incandescent 12 12V AC/DC 24 24V AC/DC 48 48V AC/DC 10 120V AC/DC 20 240V AC/DC Universal — LED 2 12…130V AC/DC Dual Input 16 120V AC 24V AC/DC 24 (Dual input diode only) 1 LED illumination option is not available with diode type dual input. 12 Type 4/4X/13 Pilot Light Push-to-Test1 Cat. No. Cat. No. 800H-SR00 800H-SRB00XX 800H-QR24R 800H-QRT24R 800H-QR24G 800H-QRT24G 800H-QR24A 800H-QRT24A — — 800H-QRH2R 800H-QRTH2R 800H-QRH2G 800H-QRTH2G 800H-QRH2A 800H-QRTH2A 800H-PR16R 800H-PRT16R 800H-PR16G 800H-PRT16G 800H-PR16A 800H-PRT16A 800H-PRH16R 800H-PRTH16R 800H-PRH16G 800H-PRTH16G 800H-PRH16A 800H-PRTH16A — — ♣ Diode type dual input provides circuit isolation via opposing diodes. Not recommended for use with solid-state outputs. ♠ Glass lens available on 800T pilot lights only. Not available on push-to-test units. 13 www.ab.com/catalogs 10-20 Preferred availability cat. nos. are bold. Publication A117-CA001A-EN-P g Lens Color Code Color Blank A B C G R W No lens Amber Blue Clear Green Red White Glass Code ♠ Blank D E F H J K h Contact Blocks (Push-to-test units only) Code Description Standard Blank 1 N.O. - 1 N.C. PenTUFF (Low Voltage) AV 1 N.O. - 1 N.C. Class 1, Div. 2/Zone 2 Logic Reed AR 1 N.O. - 1 N.C. Sealed Switch AP 1 N.O. - 1 N.C. Stackable Sealed Switch AY 1 N.O. - 1 N.C. Bulletin 800T/H 30.5 mm Push Buttons Specifications Specifications1 Electrical Ratings Refer to the contact ratings tables on page 10-4. 2200V for one minute, 1300V for one minute (Logic Reed) 1 000 000 at max. rated load, 200 000 at max. rated load (Logic Reed) Contact ratings Dielectric strength Electrical design life cycles Mechanical Ratings 10…2000 Hz, 1.52 mm displacement (peak-to-peak) max./ 10 G max. (except Logic Reed) 1/2 cycle sine wave for 11 ms ≥ 25 G (contact fragility) and no damage at 100 G Type 1/4/12/13 (800T); Type 1/4/4X/12/13 (800H); EN/IEC 60529 IP66/65 Vibration Shock Degree of protection Mechanical design life cycles Push buttons Selector switches 0 (Momentary, non-illuminated) (Momentary, illuminated) (Push-pull/twist-to-release) (Non-illuminated) (Illuminated, key-operated) 1 10 000 000 min. 250 000 min. 250 000 min. 1 000 000 min. 200 000 min. 25 000 min. 200 000 min. Shallow, mini, and low-voltage contact blocks: Slow, double make and break Logic Reed and sealed switch contact blocks: Single break magnetic #18…14 AWG (#18…10 Max Duty) / 6…8 lb•in Potentiometers All other devices Contact operation Wire gauge/Terminal screw torque Typical operating forces 2 3 Flush, extended button, standard mushroom, jumbo plastic mushroom: 2 lbs max. Jumbo and extended aluminum mushroom head: 3.95 lbs max. Maintained selector switch: 3.6 in•lb max. 3.6 in•lb to stop, 0.2 in•lb to return 5 lb max. 8.0 lb max. push or pull 8 lb max. push to in position or pull to center position (15 lb max. pull to out position) 9 lbs max. push or pull 30 in•oz max. twist, 6 in•oz minimum return Rotational torque 3…12 in•oz; stopping torque 12 in•lb (minimum) 1 lb 1 lb max. 3 lb max. at 0.205 in. plunger travel 1 lb max. 1.4 lb max. 1.4 lb max. 1.6 lb Environment -40…+131 °F (-40…+55 °C) -40…+185 °F (-40…+85 °C) Operators without contact blocks Spring return selector switches Illuminated push buttons and push-to-test pilot lights 2-position push-pull 3-position push-pull Twist-to-release or push-pull Potentiometer Standard Logic Reed Sealed switch Contact blocks Stackable sealed switch MaxDuty PenTUFF Self Monitoring Operating Storage Note: Operating temperatures below freezing are based on the absence of moisture and liquids. Consult your local Rockwell Automation sales office or Allen-Bradley distributor for use in lower temperature applications. Temperature range 50…95% RH from 77…140 °F (25…60 °C) per Procedure IV of MIL-STD-810C, Method 507.1 cycling test Humidity 4 5 6 7 8 9 1 Performance Data — See Important- 3. 10 11 12 13 www.ab.com/catalogs Preferred availability cat. nos. are bold. Publication A117-CA001A-EN-P 10-3 01_800TH.qxd 4/23/2008 1:48 PM Page 10-7 Item # 17 Bulletin 800T/H 30.5 mm Push Buttons Push Button Operators Momentary Contact Push Button Units, Non-Illuminated ! Flush Head Unit Cat. No. 800T-A1A Extended Head Unit Cat. No. 800T-B6A Booted Unit Cat. No. 800H-R2A Bootless Flush Head Unit Cat. No. 800H-AR1A Type 4/13 Contact Type No Contact 1 N.O. 1 N.C. 1 N.O. - 1 N.C. 1 Type 4/4X/13 Booted9 Bootless Flush Head Button Color Flush Head Extended Head Cat. No. Cat. No. Cat. No. Cat. No. Green 800T-A1 800T-B1 800H-R1 800H-AR1 Black 800T-A2 800T-B2 800H-R2 800H-AR2 Red 800T-A6 800T-B6 800H-R6 800H-AR6 Green 800T-A1D1 800T-B1D1 800H-R1D1 800H-AR1D1 Black 800T-A2D1 800T-B2D1 800H-R2D1 800H-AR2D1 Red 800T-A6D1 800T-B6D1 800H-R6D1 800H-AR6D1 Green 800T-A1D2 800T-B1D2 800H-R1D2 800H-AR1D2 Black 800T-A2D2 800T-B2D2 800H-R2D2 800H-AR2D2 Red 800T-A6D2 800T-B6D2 800H-R6D2 800H-AR6D2 Green 800T-A1A 800T-B1A 800H-R1A 800H-AR1A Black 800T-A2A 800T-B2A 800H-R2A 800H-AR2A Red 800T-A6A 800T-B6A 800H-R6A 800H-AR6A 2 3 4 5 800 T a a Code T H Protection Rating Description Metal, Type 4/13 Plastic, Type 4/4X/13 b Code Blank C Finger-Safe Guards Description No Guards Guards on Terminals c Operator Type 800T 800H Type Type Description 4/13 4/4X/13 Code Code A Flush Head AR B Extended Head BR D Mushroom Head DR Mushroom Head DX DRX less Color Cap Bootless — Guarded GR Head — Booted Head R9 d Code Blank 1 2 3 Color Cap Description Used only when ordering Operator Type DX/DRX Green Black Orange7 – A 1 c d b d (cont'd) Code 4 5 6 7 9 Color Cap Description Gray7 White7 Red Blue Yellow e Special Mushroom Head Code Description Jumbo Mushroom Head — J§ Plastic Jumbo Mushroom Head — L§ Metal Note: Special Mushroom Head options only apply to Mushroom Head operator Type Code D/DR. f Code Blank D1 D2 D3 D4 D5 D6 A1 A2 A4 A7 A B Contact Block(s) Description No Contacts Standard 1 N.O. 1 N.C. 1 N.O.E.M. 1 N.C.L.B. 1 N.O. (Mini) 1 N.C. (Mini) 1 N.C.L.B. - 1 N.O. 2 N.O.‡ 2 N.C. 1 N.C.L.B. - 1 N.C. 1 N.O. - 1 N.C. 2 N.O. - 2 N.C. A e f (cont'd) Contact Block(s) Code Description PenTUFF (Low Voltage) D1V 1 N.O. D2V 1 N.C. D3V 1 N.O.E.M. D4V 1 N.C.L.B. AV 1 N.O. - 1 N.C. BV 2 N.O. - 2 N.C. Time Delay 1 N.O. T Depress close, delayed opening 1 N.C. S Depress open, delayed closure Snap Action M 1 N.O. - 1 N.C. N 2 N.O. - 2 N.C. Class 1, Div. 2/Zone 2 Logic Reed D1R 1 N.O. D2R 1 N.C. A2R 2 N.O.‡ A4R 2 N.C. AR 1 N.O. - 1 N.C. BR 2 N.O. - 2 N.C. f 6 f (cont'd) Contact Block(s) Code Description Class 1, Div. 2/Zone 2 Sealed Switch D1P 1 N.O. D2P 1 N.C. A2P 2 N.O. A4P 2 N.C. AP 1 N.O. - 1 N.C. BP 2 N.O. - 2 N.C Stackable Sealed Switch D1Y 1 N.O. D2Y 1 N.C. A2Y 2 N.O. A4Y 2 N.C. AY 1 N.O. - 1 N.C. BY 2 N.O. - 2 N.C Time Delay Contacts Series C field installable kits can only be used with Series T or later operators. Adjustable range of 0.5 to 15 s + 25%. Maximum continuous current Ith 5 A. Snap Action Contacts Snap action contacts feature a quick make, quick break snapaction mechanism that is only available on factory assembled units. Maximum continuous current Ith 10 A. 7 8 9 10 11 12 9 Underlying operators are "flush head" type, except red which are "extended head". Boot material is hyplon with brass threaded insert. 7 Not available for booted operators. ‡ A2 and A2R contact blocks cannot be stacked upon, but can stack on other contact blocks. § Jumbo mushroom heads not available in white color. Visit our website: www.ab.com/catalogs Preferred availability cat. nos. are printed in bold 10-7 13 Bulletin_800T_800H_d.qxd 30/01/2004 15:00 Page 10-79 Item # 18 Bulletin 800T/800H 30.5 mm Push Buttons Accessories Αχχεσσοριεσ Contact Blocks Packaged in kit form for field installation. All necessary mounting hardware is provided with each contact block kit. Contact ratings are listed on page 10-52. Note: It is not recommended to mount more than four contact blocks on any one non-illuminated operator, (maximum two blocks deep). Contact blocks cannot be stacked onto power modules, so illuminated operators are limited to two contact blocks. Sealed switch contact blocks are not stackable, and are limited to two blocks per operator. Time delay contacts are only available as one circuit per operator. Shallow Block Contact Type 1 N.O. 1 N.C. 1 N.O.E.M. 1 N.C.L.B. 1 N.O. - N.C. 2 N.O. 2 N.C. 1 N.C.L.B. - 1 N.O. 1 N.C.L.B. - 1 N.C. PenTUFF (Low Voltage) Contact Block Shallow Block✶† Cat. No. 800T-XD1 800T-XD2 800T-XD3 800T-XD4 800T-XA 800T-XA2§ 800T-XA4 800T-XA1 800T-XA7 PenTUFF (Low Voltage) Block✶† Cat. No. 800T-XD1V 800T-XD2V 800T-XD3V 800T-XD4V 800T-XAV — — — — Logic Reed Block‡ Cat. No. 800T-XD1R 800T-XD2R — — 800T-XAR 800T-XA2R§ 800T-XA4R — — Mini Block Self Monitoring Contact Block Contact Type 1 N.C.L.B. (wired in series with 1 N.O. monitoring contact) Sealed Switch Block Logic Reed Block S.M.C.B.✶➤ Cat. No. 800TC-XD4S Contact Type 1 N.O. 1 N.C. 1 N.C.L.B. Stackable Sealed Switch Block Sealed Switch Block‡ Cat. No. 800T-XD1P 800T-XD2P — — 800T-XAP — — — — Time Delay Block Mini Block✶ Cat. No. 800T-XD5 800T-XD6 — Time Delay Block♣ Cat. No. 800T-XT 800T-XS — Stackable Sealed Switch Block‡ Cat. No. 800T-XD1Y 800T-XD2Y — — 800T-XAY 800T-XA2Y 800T-XA4Y — — MaxDuty Block MaxDuty Block Cat. No. 800T-XD1M 800T-XD2M 800T-XD4M ✶ Contact blocks with normally closed contacts meet direct drive positive opening standard requirements when properly fused to IEC 269-1 and 269-2. Shallow/mini contacts: 10 A gl or N type cartridge fuse. PenTUFF contacts: 6 A gl or N type cartridge fuse. † Specify Bulletin 800TC for finger-safe contact blocks. Example: Cat. No. 800T-XA becomes Cat. No. 800TC-XA. ‡ 800T operator using sealed switch and logic reed contact blocks and installed in a suitable enclosure are UL Listed as suitable for use in Class I, Division 2/Zone 2 hazardous locations. § Additional contacts cannot be stacked on XA2 and XA2R contact blocks. ♣ For contact ratings, see page 10-51. ➤ For use with 2-position push-pull or push-pull/twist operators only. Must be mounted on the first level of the operator. The N.O. monitoring contact automatically closes when the S.M.C.B. is properly installed onto the operator. If the S.M.C.B. is separated from the operator, the N.O. monitoring contact automatically opens. Shallow Contact Block Hardware Cat. No. 800T-N335 800T-N336 800T-N337 Description Contact Block Mounting Screw Screw Retainer Actuator Extender Visit our website: www.ab.com/catalogs 10-79 Item # 19 FEDERAL SIGNAL CORPORATION Vibratone ® Horns Models 350 and 450 The Models 350 and 450 Vibratone Horns produce a very loud horn tone by the electro-mechanical vibration of a diaphragm. Capable of reproducing coded blasts or sustained tones, Federal Signal’s Vibratone horn is excellent for general alarm, start and dismissal, coded paging, and process control signaling in areas of high ambient noise levels. DESIGNED FOR ROUTINE SIGNALING • Range of up to 200 feet (61m) • Coded or sustained tones • Model 350 – 12, 24, 120 and 240VAC; Model 450 – 12, 24, 125 and 250VDC • Model 350 produces 100dB at 10’ (110dB at 1 m); Model 450 produces 99dB at 10’ (109dB at 1 m) • UL and cUL Listed, CSA Certified, FM Approved • Type 4X when installed with Panel Mount Gasket Kit or Weatherproof Backbox (Model WB); Type 4X and Type 12 when installed with Surface Mount Trim Ring (Model TR) The Vibratone Model 350 is available in AC voltages; 12VAC, 24VAC, 120VAC and 240VAC. The Model 350 produces 100dB @ 10’, except the 12VAC model, which produces 94dB @ 10’. The Model 450 is available in DC voltages; 12VDC, 24VDC, 125VDC and 250VDC. The Model 450 produces 99dB @ 10’. Vibratone mounting options provide for surface, flush or semiflush mounting on walls, panels, in cabinets, on 4-inch square outlet boxes, or in concrete and deep wall constructions. Installed on the front of a Vibratone Horn, the optional Model PR Projector or Model PR2 Double Projector direct sound output straight ahead or to the sides, optimizing sound output for long, narrow rooms or corridors. Vibratone horns are UL Listed, cUL Listed, CSA Certified and FM Approved. They are designed and approved for use in Type 4X applications when installed with the Panel Mount Gasket Kit or Weatherproof Backbox (Model WB). They are approved for Type 4X and Type 12 applications when installed with the Surface Mount Trim Ring (Model TR, illustrated on page 124). Each Vibratone horn is enclosed in a zinc die-cast housing and sealed with grey powder-coat paint. The Model 350 features a stainless steel diaphragm. The Model 450 utilizes an aluminum diaphragm and heavy duty contacts. The rugged construction of the Vibratone horns resists vandalism and the effects of harsh industrial environments. Compact size, loud output and heavy-duty construction make the VibraTone horns ideal for industrial and institutional signaling applications. Model Voltage Operating Current Decibels @ 10' 1m 350 350 350 350 450 450 450 450 12VAC 50/60Hz 24VAC 50/60Hz 120VAC 50/60Hz 240VAC 50/60Hz 12VDC 24VDC 125VDC 250VDC 0.90 amps 0.90 amps 0.18 amps 0.09 amps 0.50 amps 0.25 amps 0.05 amps 0.03 amps 94 100 100 100 99 99 99 99 104 110 110 110 109 109 109 109 FB VIBRATONE ® HORNS (350/450) PR FG FB 350 SF 350 350 PR FG 350 N B 350 2 TR PR 350 PR2 NB 350 290A2450-02 WB HOW TO ORDER OPTIONS ® FB Wall box for flush mounting the Vibratone horn in stud, 4" block, or other shallow wall construction; 43/8" square box; 27/8" deep; shipping weight 2 lbs. (0.91 kg) FBL Same as FB, but 313/16" deep for 6" x 8" concrete block, cinder block or other deep wall construction; shipping wt. 3 lbs. (1.36 kg) FG Flush grille which attaches to the basic unit and serves as the cover of the plastered-in FB flush box; 6" H x 6" W x 1/8" D; shipping wt. 1 lb. (0.45 kg) K8435666A Optional Panel Mounting Gasket Kit includes a gasket and hardware for surface or flush mounting the horn for NEMA Type 4 applications. 1 NB 4" square box with / " & / " knockouts for interior mountings; 1 / " deep; shipping weight 1 lb. (0.45 kg) PR Projector which concentrates sound into a basic area when attached to the basic model 350/450 units; 4" H x 4" W x 6" D; shipping weight 1 lb. (0.45 kg) PR2 Double projector directs sounds to both sides when attached to the basic model 350/450 units; ideal for use in hallways; 4" H x 111/2" W x 4" D; shipping weight 2 lbs. (0,91 kg) SF Stamped surface plate used for installations on plastered-in 4" outlet switch boxes for semi-flush mountings; 6"H x 6" W x 1/2" D; shipping weight 1 lb. (0.45 kg) TR Gasketed trim ring allowing surface mount installations of 350/450 units while maintaining Type12 and Type4X rating of enclosure. WB Cast aluminum neoprene-gasketed weatherproof housing for outside use, complete with mounting lugs; tapped for 1/2", 3⁄4” conduit; 43/8" square box; 2" deep mounting lugs on 41/2" centers; shipping weight 1 lb. (0.45 kg) S P E C I F I C AT I O N S Operating Temp.: Net Weight: Shipping Weight: Height: Width: Depth: 2 3 1 4 -65°F to 150°F 1.4 lbs. 1.5 lbs. 4.0" 4.0" 2.5" 2 • Specify model and voltage • Specify options from list • Please refer to Model Number Index 350/450 beginning on page 378 R E P L A C E M E N T PA RT S Description Panel Mount Gasket Kit Coil (120VAC only) Volume Control Kit Part Number K8435666A KFC1516C K8435663B -54°C to 66°C 0.6 kg 0.7 kg 102 mm 102 mm 64 mm 2645 Federal Signal Dr., University Park, IL 60466 Tel: 708.534.4756 Fax: 708.534.4852 www.federalsignal-indust.com 113 Item # 20 FEDERAL SIGNAL CORPORATION StreamLine ® Low Profile Strobe Light Models LP3P, LP3S, LP3T Federal Signal introduces the Model LP3 low profile strobe light. This Type 4X strobe is available in five colors: amber, blue, clear, green and red. PERFECT SIZE MEETS SUPERIOR PERFORMANCE! • Surface mount, T-mount, or integrated 1/2-inch pipe mount • Five dome colors • Screw-on lens • Low profile — Model LP3S is only 5" high • The LP3 is offered in three mounting configurations. LP3P features an integrated 1/2-inch NPT pipe mount. LP3S features a three-hole surface mount — ideal for control panels and other flat or flush surfaces. The “T-mount” LP3T has a popular 2-hole design for wall or flush mounting. Both the LP3S and LP3T include a surface gasket to complete the Type 4X installation. An optional dome guard is available for use with the LP3S and LP3T. All LP3 units feature a threaded screwon lens that provides tool-free wiring and strobe tube replacement. The strobe tube is rated for 7,000 hours. The LP3 comes in three voltage variations: 12-48VDC, 120VAC and 240VAC. The state-of-the-art strobe mechanism produces 2.2 joules of energy, while drawing relatively low level amperage. Available in 12-48VDC, 120VAC and 240VAC • Type 4X, IP66 enclosure • PLC and triac compatible • UL and cUL Listed, CSA Certified, CE pending 1 2 StreamLine® strobes feature high-quality, long-life strobe lamps which are designed to reduce tungsten build-up for longer lamp maintenance cycles. Careful consideration is given to the relationship between lamp shape and lens design for maximum light output. StreamLine products make use of surface mount technology, which provides a more powerful light in a much smaller package. The dry-electrolyte capacitor used in StreamLine products runs cooler than those used in many competitive strobes, resulting in a more reliable product that won’t fail due to overheating. Model Voltage Operating Current Flash Rate/ Minute Joule Output Candlepower ECP2 Peak1 LP3 12-48VDC 0.44-0.10 amps 65-95 2.2 175,000 51.5 LP3 120VAC 0.10 amps 65-95 2.2 175,000 51.5 LP3 240VAC 0.07 amps 65-95 2.2 175,000 51.5 Peak candlepower is the maximum light intensity generated by a flashing light during its light pulse ECP (Effective Candlepower) is the intensity that would appear to an observer if the light were burning steadily VISUAL STREAMLINE ® LOW PROFILE STROBE LIGHT (LP3S, LP3P, LP3T) LP3S Dome Housing Lens Gasket Set Screw " ) .25 4mm (6. 1 /2" Pipe Mount Custom Strobe Tube LP3P Snap-in Printed Circuit Board Assembly Power Connection Schematic Housing Surface Mount Housing T-mount Gasket Gasket Mounting Surface Mounting Surface HOW TO ORDER S P E C I F I C AT I O N S Lamp Life:* Lamp Style: Operating Temperature Net Weight: Shipping Weight: Diameter: Height (from bottom): LP3P LP3S LP3T *Optimal hours under ideal conditions. LP3T** 7,000 hours Strobe -31°F to 150°F 7.3 oz. 8.5 oz. 3.125" 7,000 hours Strobe -35°C to 66°C 206.96 g 240.98 g 7.94 cm 5.7" 5.0" 5.1" 14.48 cm 12.7 cm 12.95 cm • Specify model, voltage and color • Specify options Dome guard for LP3S and LP3T (LP3G) **LP3T-120 & 240VAC shown R E P L A C E M E N T PA RT S Description Dome, Amber Dome, Blue Dome, Clear Dome, Green Dome, Red Strobe Tube Part Number K8589006A K8589006A-01 K8589006A-02 K8589006A-03 K8589006A-04 K149130A 2645 Federal Signal Dr., University Park, IL 60466 Tel: 708.534.4756 Description PC Assembly, 12-48VDC PC Assembly, 120VAC PC Assembly, 240VAC Gasket, Lens Gasket, LP3S Gasket, LP3T Fax: 708.534.4852 Part Number K2001316A K2001317A K2001317A-01 K8589013A K8589011A K8589012A www.federalsignal-indust.com 63 Item # 21 Item # 22 Extract from the online catalog UT 4 Order No.: 3044102 http://eshop.phoenixcontact.de/phoenix/treeViewClick.do?UID=3044102 Universal terminal block with screw connection, cross section: 0,14 - 4 mm², AWG: 26 - 10, width: 6.2 mm, color: Gray Product notes WEEE/RoHS-compliant since: 01/01/2003 Commercial data EAN 4017918960391 Pack 50 Pcs. Customs tariff 85369010 Weight/Piece 0.009424 KG Catalog page information Page 27 (CL-2007) http:// www.download.phoenixcontact.com Please note that the data given here has been taken from the online catalog. For comprehensive information and data, please refer to the user documentation. The General Terms and Conditions of Use apply to Internet downloads. Technical data General Number of levels 1 Number of connections 2 Color gray PHOENIX CONTACT Inc., USA http://www.phoenixcon.com Page 1 / 6 Apr 29, 2008 UT 4 Order No.: 3044102 http://eshop.phoenixcontact.de/phoenix/treeViewClick.do?UID=3044102 Insulating material PA Inflammability class acc. to UL 94 V0 Dimensions Width 6.2 mm Length 47.7 mm Height NS 35/7,5 47.5 mm Height NS 35/15 55 mm Technical data Maximum load current 41 A (with 6 mm conductor cross section) Rated surge voltage 8 kV Pollution degree 3 Surge voltage category III Insulating material group I Connection in acc. with standard IEC 60947-7-1 Nominal current IN 32 A (with 4 mm conductor cross section) Nominal voltage UN 1000 V Open side panel ja 2 2 Connection data Conductor cross section solid min. 0.14 mm Conductor cross section solid max. 6 mm Conductor cross section stranded min. 0.14 mm Conductor cross section stranded max. 6 mm Conductor cross section AWG/kcmil min. 26 Conductor cross section AWG/kcmil max 10 Conductor cross section stranded, with ferrule without plastic sleeve min. 0.25 mm Conductor cross section stranded, with ferrule without plastic sleeve max. 4 mm Conductor cross section stranded, with ferrule with plastic sleeve min. 0.25 mm Conductor cross section stranded, with ferrule with plastic sleeve max. 4 mm 2 conductors with same cross section, solid min. 0.14 mm 2 conductors with same cross section, solid max. 1.5 mm PHOENIX CONTACT Inc., USA http://www.phoenixcon.com 2 2 2 2 2 2 2 2 2 2 Page 2 / 6 Apr 29, 2008 UT 4 Order No.: 3044102 http://eshop.phoenixcontact.de/phoenix/treeViewClick.do?UID=3044102 2 conductors with same cross section, stranded min. 0.14 mm 2 conductors with same cross section, stranded max. 1.5 mm 2 conductors with same cross section, stranded, TWIN ferrules with plastic sleeve, min. 0.5 mm 2 conductors with same cross section, stranded, TWIN ferrules with plastic sleeve, max. 2.5 mm 2 conductors with same cross section, stranded, ferrules without plastic sleeve, min. 0.25 mm 2 conductors with same cross section, stranded, ferrules without plastic sleeve, max. 1.5 mm Type of connection Screw connection Stripping length 9 mm Internal cylindrical gage A4 Screw thread M3 Tightening torque, min 0.6 Nm Tightening torque max 0.8 Nm 2 2 2 2 2 2 Certificates / Approvals CSA Nominal voltage UN 600 V Nominal current IN 30 A AWG/kcmil 26-10 CUL Nominal voltage UN 600 V Nominal current IN 30 A AWG/kcmil 26-10 UL Nominal voltage UN 600 V Nominal current IN 30 A AWG/kcmil 26-10 Certification CB, CSA, CUL, DNV, GL, LR, UL, VDE-PZI PHOENIX CONTACT Inc., USA http://www.phoenixcon.com Page 3 / 6 Apr 29, 2008 Item # 23 Extract from the online catalog UT 4-PE Order No.: 3044128 http://eshop.phoenixcontact.de/phoenix/treeViewClick.do?UID=3044128 Universal terminal block with screw connection, cross section: 0.14 - 4 mm², AWG: 26 - 10, width: 6.2 mm, color: Green-yellow Product notes WEEE/RoHS-compliant since: 01/01/2003 Commercial data EAN 4017918960407 Pack 50 Pcs. Customs tariff 85369010 Weight/Piece 0.01325 KG Catalog page information Page 33 (CL-2007) http:// www.download.phoenixcontact.com Please note that the data given here has been taken from the online catalog. For comprehensive information and data, please refer to the user documentation. The General Terms and Conditions of Use apply to Internet downloads. Technical data General Number of levels 1 Number of connections 2 Color green-yellow PHOENIX CONTACT Inc., USA http://www.phoenixcon.com Page 1 / 7 Apr 29, 2008 UT 4-PE Order No.: 3044128 http://eshop.phoenixcontact.de/phoenix/treeViewClick.do?UID=3044128 Insulating material PA Inflammability class acc. to UL 94 V0 Dimensions Width 6.2 mm Length 47.7 mm Height NS 35/7,5 47.5 mm Height NS 35/15 55 mm Technical data Rated surge voltage 8 kV Pollution degree 3 Surge voltage category III Insulating material group I Connection in acc. with standard IEC 60947-7-2 Open side panel ja Connection data Conductor cross section solid min. 0.14 mm Conductor cross section solid max. 6 mm Conductor cross section stranded min. 0.14 mm Conductor cross section stranded max. 6 mm Conductor cross section AWG/kcmil min. 26 Conductor cross section AWG/kcmil max 10 Conductor cross section stranded, with ferrule without plastic sleeve min. 0.25 mm Conductor cross section stranded, with ferrule without plastic sleeve max. 4 mm Conductor cross section stranded, with ferrule with plastic sleeve min. 0.25 mm Conductor cross section stranded, with ferrule with plastic sleeve max. 4 mm 2 conductors with same cross section, solid min. 0.14 mm 2 conductors with same cross section, solid max. 1.5 mm 2 conductors with same cross section, stranded min. 0.14 mm 2 conductors with same cross section, stranded max. 1.5 mm PHOENIX CONTACT Inc., USA http://www.phoenixcon.com 2 2 2 2 2 2 2 2 2 2 2 2 Page 2 / 7 Apr 29, 2008 UT 4-PE Order No.: 3044128 http://eshop.phoenixcontact.de/phoenix/treeViewClick.do?UID=3044128 2 conductors with same cross section, stranded, TWIN ferrules with plastic sleeve, min. 0.5 mm 2 conductors with same cross section, stranded, TWIN ferrules with plastic sleeve, max. 2.5 mm 2 conductors with same cross section, stranded, ferrules without plastic sleeve, min. 0.25 mm 2 conductors with same cross section, stranded, ferrules without plastic sleeve, max. 1.5 mm Type of connection Screw connection Stripping length 9 mm Internal cylindrical gage A4 Screw thread M3 Tightening torque, min 0.6 Nm Tightening torque max 0.8 Nm 2 2 2 2 Certificates / Approvals CSA AWG/kcmil 26-10 CUL AWG/kcmil 26-10 UL AWG/kcmil 26-10 Certification CB, CSA, CUL, DNV, GL, LR, UL, VDE-PZI requested approbations Certification Ex: IECEx, KEMA-EX Accessories Item Designation Description ATP-UT Partition plate, for visual and electrical separation of terminal groups, width: 2 mm, color: gray Assembly 3047167 PHOENIX CONTACT Inc., USA http://www.phoenixcon.com Page 3 / 7 Apr 29, 2008 UT 4-PE Order No.: 3044128 http://eshop.phoenixcontact.de/phoenix/treeViewClick.do?UID=3044128 3047028 D-UT 2,5/10 Cover, for terminal block UT and UT...-PE, width 2.2 mm, color: Gray 0801762 NS 35/ 7,5 CU UNPERF 2000MM DIN rail, material: Copper, unperforated, height 7.5 mm, width 35 mm, length: 2 m 1207640 NS 35/ 7,5 PERF 755MM NS 35 DIN rail, height 7.5 mm, length 755 mm 1207653 NS 35/ 7,5 PERF 955MM NS35 DIN rail, height 7.5 mm, length 955 mm 1207666 NS 35/ 7,5 PERF 1155MM NS 35 DIN rail, height 7.5 mm, length 1155 mm 0801733 NS 35/ 7,5 PERF 2000MM DIN rail, material: Steel, perforated, height 7.5 mm, width 35 mm, length: 2 m 0801681 NS 35/ 7,5 UNPERF 2000MM DIN rail, material: Steel, unperforated, height 7.5 mm, width 35 mm, length: 2 m 1201756 NS 35/15 AL UNPERF 2000MM DIN rail, deep-drawn, high profile, unperforated, 1.5 mm thick, material: Aluminum, height 15 mm, width 35 mm, length 2 m 1201895 NS 35/15 CU UNPERF 2000MM DIN rail, material: Copper, unperforated, 1.5 mm thick, height 15 mm, width 35 mm, length: 2 m 1207679 NS 35/15 PERF 755MM NS 35 DIN rail, perforated, height 15 mm, length 755 mm 1207682 NS 35/15 PERF 955MM NS 35 DIN rail, perforated, height 15 mm, length 955 mm 1207695 NS 35/15 PERF 1155MM NS 35 DIN rail, perforated, height 15 mm, length 1155 mm 1201730 NS 35/15 PERF 2000MM DIN rail, material: Steel, perforated, height 15 mm, width 35 mm, length: 2 m 1201714 NS 35/15 UNPERF 2000MM DIN rail, material: Steel, unperforated, height 15 mm, width 35 mm, length: 2 m 1201798 NS 35/15-2,3 UNPERF 2000MM DIN rail, material: Steel, unperforated, 2.3 mm thick, height 15 mm, width 35 mm, length: 2 m 3030336 FBS 2-6 Plug-in bridge for cross-connections in the terminal center, 2-pos., color: Red 3030242 FBS 3-6 Plug-in bridge for cross-connections in the terminal center, 3-pos., color: Red 3030255 FBS 4-6 Plug-in bridge for cross-connections in the terminal center, 4-pos., color: Red 3030349 FBS 5-6 Plug-in bridge for cross-connections in the terminal center, 5-pos., color: Red 3030271 FBS 10-6 Plug-in bridge for cross-connections in the terminal center, 10pos., color: Red 3030365 FBS 20-6 Plug-in bridge for cross-connections in the terminal center, 20pos., color: Red 3032224 FBS 50-6 Plug-in bridge for cross-connections in the terminal center, 50pos., color: Red Bridges PHOENIX CONTACT Inc., USA http://www.phoenixcon.com Page 4 / 7 Apr 29, 2008 UT 4-PE Order No.: 3044128 http://eshop.phoenixcontact.de/phoenix/treeViewClick.do?UID=3044128 General 3022276 CLIPFIX 35-5 Snap-on end bracket, for NS 35/7.5 or NS 35/15 DIN rail, can be fitted with Zack strip ZB 5 and ZBF 5, terminal strip marker KLM 2 and KLM, parking facility for FBS...5, FBS...6, KSS 5, KSS 6, width: 5,15 mm, color: gray 0811228 X-PEN 0,35 Marker pen without ink cartridge, for manual labeling of markers, labeling extremely wipe-proof, line thickness 0.35 mm 1051016 ZB 6,LGS:FORTL.ZAHLEN Zack strip, 10-section, printed horizontally: with the numbers, 1-10, 11-20 etc. up to 991-1000, color: white 5060935 ZB 6/WH-100:UNBEDRUCKT Zack strip, unprinted: For individual labeling with M-PEN, ZB-T or CMS system, large batch, sufficient for labeling 1000 terminal blocks, for a terminal width of 6.2 mm, color: White 1050499 ZB 6:SO/CMS Zack strip, 10-section, divisible, special printing, marking according to customer requirements 0201689 MPS-IH BU Insulating sleeve (blue), for MPS metal part to be ordered separately (0201744) 0201676 MPS-IH RD Insulating sleeve (red), for MPS metal part to be ordered separately (0201744) 0201663 MPS-IH WH Insulating sleeve (white), for MPS metal part to be ordered separately (0201744) 0201744 MPS-MT Test plug, consisting of: Metal part for 2.3 mm diameter socket hole 3030925 PAI-4 Test adapter, for 4 mm diameter test plug PS and safety test plug, makes contact in the bridge shaft 3030996 PS-6 Modular test plug, for individual assembly of test plug strips, for UT, ST, DT and QT terminal blocks, can be labeled with ZBF 6, color: Red SZS 0,6X3,5 Screwdriver, bladed, matches all screw terminal blocks up to 4.0 mm² connection cross section, blade: 0.6 x 3.5 mm, without VDE approval Marking Plug/Adapter Tools 1205053 PHOENIX CONTACT Inc., USA http://www.phoenixcon.com Page 5 / 7 Apr 29, 2008 UT 4-PE Order No.: 3044128 http://eshop.phoenixcontact.de/phoenix/treeViewClick.do?UID=3044128 Drawings Circuit diagram PHOENIX CONTACT Inc., USA http://www.phoenixcon.com Page 6 / 7 Apr 29, 2008 UT 4-PE Order No.: 3044128 http://eshop.phoenixcontact.de/phoenix/treeViewClick.do?UID=3044128 Address PHOENIX CONTACT Inc., USA 586 Fulling Mill Road Middletown, PA 17057,USA Phone (800) 888-7388 Fax (717) 944-1625 http://www.phoenixcon.com © 2008 Phoenix Contact Technical modifications reserved; PHOENIX CONTACT Inc., USA http://www.phoenixcon.com Page 7 / 7 Apr 29, 2008 Item # 24 tnb06_wrtrm_sece_p04_05 8/9/07 1:07 PM Page E-5 Item # 25 and Accessories How to Order Ty-Duct ® Ordering the Ty-Duct® products you need is as easy as 1, 2, 3! After selecting the appropriate Ty-Duct solutions for your application, make sure you complete the following checklist. and Accessories For Ty-Duct Wiring Duct and Covers: 1 Specify color [ _ ] = space for color identifier: 2 Indicate if you want the duct without mounting holes W = White 3 Indicate if you want an adhesive-backed duct (not available in Wide Slot Duct — Halogen Free) 2 G = Gray B = Black I = Intrinsic Blue To order duct without mounting holes, add suffix NM to catalog number. Example: TY75X1WPG6NM is a .75" x 1" wide slot gray duct with no mounting holes. 3 To order Adhesive-Backed Duct, add suffix A to Catalog Number. Example: TY75x15WPB6A is a .75" x 1.5" wide slot black duct with adhesive backing. Shelf life for adhesive is 1 year. Nominal Width x Nominal Height CAT. NO. SIZE (W x H) IN. MM DESCRIPTION TY75X1WP[ G ]6NM .75 x 1 Wide Slot Duct TY75X15WP[B ]6A .75 x 1.5 Wide Slot Duct TY75X2WP[ I ]6 .75 x 2 Wide Slot Duct SP = Solid WP = Wide Slot NP = Narrow Slot RP = Round Hole 1 0.94 x 1.09 0.94 x 1.56 0.94 x 2.07 TY2D[ SP ][ G ]6 2" High Wall Divider TY75CP[ _ ]6 DUCT STD. COVER STD. LENGTH CTN. QTY. CTN. QTY. (FT.) 120 120 120 LENGTH STD. (FT.) CTN. QTY 6 6 Standard lengths are 6 feet. 120 Corner Strip sample shown below. Joining Strips are ordered the same way. LENGTH STD. (FT.) CTN. QTY CAT. NO. DESCRIPTION TYCS[ G ]6 Corner Strip 6 120 TYJS[ G ]6 Joining Strip 6 120 Catalog Number must be completed by adding suffix G for Gray, W for White, I for Intrinsic Blue, B for Black. Example: TY2DSPG6 is a 2" high solid wall gray divider. United States Tel: 901.252.8000 800.816.7809 Fax: 901.252.1354 120 For Ty-Duct Corner & Joining Strips: Catalog Number must be completed by adding suffix SP for Solid or WP for Wide Slot. Example: TY2DSPG6 is a 2" high solid wall gray divider. DESCRIPTION COVER CAT. NO. Catalog Number must be completed by adding suffix G for Gray, W for White, I for Intrinsic Blue, B for Black. Example: TY75x2WPI6 is a .75" x 2" wide slot intrinsic blue duct. Cover color must be specified also. For Ty-Duct Dividers: CAT. NO. 23.9 x 27.7 23.9 x 39.6 23.9 x 52.6 Standard Carton Quantity Canada Tel: 450.347.5318 Fax: 450.347.1976 Catalog Number must be completed by adding suffix G for Gray, W for White, I for Intrinsic Blue, B for Black. Example: TYCSG6 is a gray corner strip. Technical Services Tel: 888.862.3289 www.tnb.com E-5 tnb06_wrtrm_sece_p08_09 8/9/07 1:06 PM Page E-8 and Accessories Wide Slot Wiring Duct and Accessories Greater sidewall rigidity with increased versatility! Two-Point Contact Design Wide Slot Wiring Duct — PVC • Wide fingers and slots increase rigidity and enable insertion of bundles • Non-slip cover does not slide easily and resists vibration • Rounded edges keep hands and wires free of abrasion • V-shaped slot lead-in enables easier and faster wire installation Flush Cover Design • Dual score lines are designed to yield clean breakoffs at the base of the slot and the duct • Restricted slot design makes sure that wires are held with or without the cover inserted • Flush cover attaches flush with sidewall for finished look Dual Score Lines • Improved flush sidewall and cover style for greater wire capacity • Versatile North American and DIN Standard mounting holes enables same duct for multiple applications • Constructed of flame-retardant PVC • Integrated mounting holes — larger sizes include staggered holes for mounting flexibility (see page E-23 for illustration) • Lead-free construction Wide Fingers & Slots Grooved Cover V-Shaped Slot Lead-In Embossed Holes E-8 www.tnb.com United States Tel: 901.252.8000 800.816.7809 Fax: 901.252.1354 Canada Tel: 450.347.5318 Fax: 450.347.1976 Technical Services Tel: 888.862.3289 tnb06_wrtrm_sece_p08_09 8/9/07 1:06 PM Page E-9 and Accessories Wide Slot Wiring Duct W For a complete listing of Wide Slot dimensional details see page E-23. H Bottom View CAT. NO. DESCRIPTION TY75X1WP[ _ ]6 TY75X15WP[ _ ]6 TY75X2WP[ _ ]6 TY1X1WP[ _ ]6 TY1X15WP[ _ ]6 TY1X2WP[ _ ]6 TY1X3WP[ _ ]6 TY1X4WP[ _ ]6 TY15X1WP[ _ ]6 TY15X15WP[ _ ]6 TY15X2WP[ _ ]6 TY15X3WP[ _ ]6 TY15X4WP[ _ ]6 TY2X1WP[ _ ]6 TY2X15WP[ _ ]6 TY2X2WP[ _ ]6 TY2X3WP[ _ ]6 TY2X4WP[ _ ]6 TY2X5WP[ _ ]6 TY25X2WP[ _ ]6 TY25X3WP[ _ ]6 TY25X4WP[ _ ]6 TY3X1WP[ _ ]6 TY3X2WP[ _ ]6 TY3X3WP[ _ ]6 TY3X4WP[ _ ]6 TY3X5WP[ _ ]6 TY4X15WP[ _ ]6 TY4X2WP[ _ ]6 TY4X3WP[ _ ]6 TY4X4WP[ _ ]6 TY4X5WP[ _ ]6 TY6X4WP[ _ ]6 .75 x 1 Wide Slot Duct .75 x 1.5 Wide Slot Duct .75 x 2 Wide Slot Duct 1 x 1 Wide Slot Duct 1 x 1.5 Wide Slot Duct 1 x 2 Wide Slot Duct 1 x 3 Wide Slot Duct 1 x 4 Wide Slot Duct 1.5 x 1 Wide Slot Duct 1.5 x 1.5 Wide Slot Duct 1.5 x 2 Wide SlotDuct 1.5 x 3 Wide Slot Duct 1.5 x 4 Wide Slot Duct 2 x 1 Wide Slot Duct 2 x 1.5 Wide Slot Duct 2 x 2 Wide Slot Duct 2 x 3 Wide Slot Duct 2 x 4 Wide Slot Duct 2 x 5 Wide Slot Duct 2.5 x 2 Wide Slot Duct 2.5 x 3 Wide Slot Duct 2.5 x 4 Wide Slot Duct 3 x 1 Wide SlotDuct 3 x 2 Wide Slot Duct 3 x 3 Wide Slot Duct 3 x 4 Wide Slot Duct 3 x 5 Wide Slot Duct 4 x 1.5 Wide Slot Duct 4 x 2 Wide Slot Duct 4 x 3 Wide Slot Duct 4 x 4 Wide Slot Duct 4 x 5 Wide Slot Duct 6 x 4 Wide Slot Duct SIZE (W x H) IN. MM 0.94 x 1.14 23.9 x 27.7 0.94 x 1.60 23.9 x 39.6 0.94 x 2.10 23.9 x 52.6 1.25 x 1.14 31.8 x 27.7 1.25 x 1.60 31.8 x 39.9 1.25 x 2.10 31.8 x 52.8 1.25 x 3.05 31.8 x 77.7 1.25 x 4.37 31.8 x 111.3 1.75 x 1.14 44.5 x 27.7 1.75 x 1.60 44.5 x 39.9 1.75 x 2.10 44.5 x 52.8 1.75 x 3.05 44.5 x 77.7 1.75 x 4.37 44.5 x 111.3 2.25 x 1.24 57.2 x 28.4 2.25 x 1.70 57.2 x 40.4 2.25 x 2.19 57.2 x 53.3 2.25 x 3.14 57.2 x 78.2 2.25 x 4.46 57.2 x 111.8 2.25 x 5.15 57.2 x 129.3 2.75 x 2.19 69.9 x 53.6 2.75 x 3.14 69.9 x 78.2 2.75 x 4.46 69.9 x 111.8 3.25 x 1.24 82.6 x 29.0 3.25 x 2.19 82.6 x 54.9 3.25 x 3.14 82.6 x 79.8 3.25 x 4.46 82.6 x 113.5 3.25 x 5.15 82.6 x 130.6 4.25 x 1.70 108.0 x 42.4 4.25 x 2.19 108.0 x 55.1 4.25 x 3.14 108.0 x 80.0 4.25 x 4.46 108.0 x 113.8 4.25 x 5.15 108.0 x 130.8 6.25 x 4.46 158.8 x 114.0 COVER CAT. NO. DUCT STD. COVER STD. LENGTH CTN. QTY CTN. QTY (FT.) TY75CP[ _ ]6 TY1CP[ _ ]6 TY15CP[ _ ]6 TY2CP[ _ ]6 TY25CP[ _ ]6 TY3CP[ _ ]6 TY4CP[ _ ]6 TY6CP[ _ ]6 120 120 120 120 120 120 120 60 120 120 120 120 60 120 120 120 60 60 60 120 60 60 120 60 60 60 60 60 60 60 30 30 30 120 6 120 6 120 6 120 6 120 6 120 6 120 6 60 6 and Accessories Side View Front View w/Cover • Standard lengths are 6 feet. [ _ ] = space for color identifier: G = Gray W = White B = Black + Catalog Number must be completed by adding suffix G for Gray, W for White, I for Intrinsic Blue, B for Black. Example: TY75X1WPG6 is a .75" x 1" wide slot gray duct. To order duct without mounting holes, add suffix NM to catalog number. Example: TY75X1WPG6NM is a .75" x 1" wide slot gray duct with no mounting holes. To order Adhesive-Backed Duct, add suffix A to Catalog Number. Example: TY75X1WPG6A is a .75" x 1" wide slot gray duct with adhesive backing. Shelf life for adhesive is 1 year. PVC vinyl duct is UL Recognized , CSA Certified and CE Compliant. I = Intrinsic Blue United States Tel: 901.252.8000 800.816.7809 Fax: 901.252.1354 Canada Tel: 450.347.5318 Fax: 450.347.1976 Technical Services Tel: 888.862.3289 www.tnb.com E-9 tnb06_wrtrm_sece_p10_11 8/9/07 1:05 PM Page E-10 and Accessories Narrow Slot Wiring Duct and Accessories Designed to fit the spacing of high-density terminal blocks! Two-Point Contact Design Narrow Slot Wiring Duct • Smaller, higher number of fingers for more concise harnessing • Non-slip cover does not slide easily and resists vibration • Rounded edges keep hands and wires free of abrasion • V-shaped slot lead-in enables easier and faster wire installation • Restricted slot design makes sure that wires are held with or without the cover inserted Flush Cover Design • Flush cover attaches flush with sidewall for finished look Two Levels of Wire Service • Versatile North American and DIN Standard mounting holes enable same duct for multiple applications • Dual score lines are designed to yield clean breakoffs at the base of the slot and the duct Dual Score Lines Three Levels of Wire Service • Finger design restricts wire from slipping along the edge; creates two or three levels of wire service (see page E-24 for illustration) • Lead-free construction • Constructed of flame-retardant PVC V-Shaped Slot Lead-In Narrow Fingers & Slots Grooved Cover Restricted Slot Design Embossed Holes E-10 www.tnb.com United States Tel: 901.252.8000 800.816.7809 Fax: 901.252.1354 Canada Tel: 450.347.5318 Fax: 450.347.1976 Technical Services Tel: 888.862.3289 tnb06_wrtrm_sece_p10_11 8/9/07 1:05 PM Page E-11 and Accessories Narrow Slot Wiring Duct W For a complete listing of Narrow Slot dimensional details see page E-24. H Side View CAT. NO. DESCRIPTION TY75X15NP[ _ ]6 TY1X1NP[ _ ]6 TY1X15NP[ _ ]6 TY1X2NP[ _ ]6 TY1X3NP[ _ ]6 TY1X4NP[ _ ]6 TY15X1NP[ _ ]6 TY15X15NP[ _ ]6 TY15X2NP[ _ ]6 TY15X3NP[ _ ]6 TY15X4NP[ _ ]6 TY2X1NP[ _ ]6 TY2X15NP[ _ ]6 TY2X2NP[ _ ]6 TY2X3NP[ _ ]6 TY2X4NP[ _ ]6 TY2X5NP[ _ ]6 TY25X2NP[ _ ]6 TY25X3NP[ _ ]6 TY25X4NP[ _ ]6 TY3X1NP[ _ ]6 TY3X2NP[ _ ]6 TY3X3NP[ _ ]6 TY3X4NP[ _ ]6 TY3X5NP[ _ ]6 TY4X2NP[ _ ]6 TY4X3NP[ _ ]6 TY4X4NP[ _ ]6 TY4X5NP[ _ ]6 .75 x 1.5 Narrow Slot Duct 1 x 1 Narrow Slot Duct 1 x 1.5 Narrow Slot Duct 1 x 2 Narrow Slot Duct 1 x 3 Narrow Slot Duct 1 x 4 Narrow Slot Duct 1.5 x 1 Narrow Slot Duct 1.5 x 1.5 Narrow Slot Duct 1.5 x 2 Narrow Slot Duct 1.5 x 3 Narrow Slot Duct 1.5 x 4 Narrow Slot Duct 2 x 1 Narrow Slot Duct 2 x 1.5 Narrow Slot Duct 2 x 2 Narrow Slot Duct 2 x 3 Narrow Slot Duct 2 x 4 Narrow Slot Duct 2 x 5 Narrow Slot Duct 2.5 x 2 Narrow Slot Duct 2.5 x 3 Narrow Slot Duct 2.5 x 4 Narrow Slot Duct 3 x 1 Narrow Slot Duct 3 x 2 Narrow Slot Duct 3 x 3 Narrow Slot Duct 3 x 4 Narrow Slot Duct 3 x 5 Narrow Slot Duct 4 x 2 Narrow Slot Duct 4 x 3 Narrow Slot Duct 4 x 4 Narrow Slot Duct 4 x 5 Narrow Slot Duct SIZE (W x H) IN. MM 0.94 x 1.60 23.9 x 39.6 1.25 x 1.14 31.8 x 27.7 1.25 x 1.60 31.8 x 39.9 1.25 x 2.10 31.8 x 52.8 1.25 x 3.05 31.8 x 77.7 1.25 x 4.37 31.8 x 111.3 1.75 x 1.14 44.5 x 27.7 1.75 x 1.60 44.5 x 39.9 1.75 x 2.10 44.5 x 52.8 1.75 x 3.05 44.5 x 77.7 1.75 x 4.37 44.5 x 111.3 2.25 x 1.24 57.2 x 28.4 2.25 x 1.70 57.2 x 40.4 2.25 x 2.19 57.2 x 53.3 2.25 x 3.14 57.2 x 78.2 2.25 x 4.46 57.2 x 111.8 2.25 x 5.15 57.2 x 129.3 2.75 x 2.19 69.9 x 53.6 2.75 x 3.14 69.9 x 78.2 2.75 x 4.46 69.9 x 111.8 3.25 x 1.24 82.6 x 29.0 3.25 x 2.19 82.6 x 54.9 3.25 x 3.14 82.6 x 79.8 3.25 x 4.46 82.6 x 113.5 3.25 x 5.15 82.6 x 130.6 4.25 x 2.19 108.0 x 55.1 4.25 x 3.14 108.0 x 80.0 4.25 x 4.46 108.0 x 113.8 4.25 x 5.15 108.0 x 130.8 COVER CAT. NO. DUCT STD. COVER STD. LENGTH CTN. QTY CTN. QTY (FT.) TY75CP[ _ ]6 TY1CP[ _ ]6 TY15CP[ _ ]6 TY2CP[ _ ]6 TY25CP[ _ ]6 TY3CP[ _ ]6 TY4CP[ _ ]6 120 120 120 120 120 60 120 120 120 120 60 120 120 120 60 60 60 120 60 60 120 60 60 60 60 60 60 30 30 120 6 120 6 120 6 120 6 120 6 120 6 120 6 and Accessories Front View w/Cover Bottom View • Standard lengths are 6 feet. [ _ ] = space for color identifier: G = Gray W = White B = Black + Catalog Number must be completed by adding suffix G for Gray, W for White, I for Intrinsic Blue, B for Black. Example: TY75X15NPB6 is a .75" x 1.5" narrow slot black duct. To order duct without mounting holes, add suffix NM to catalog number. Example: TY75X15NPB6NM is a .75" x 1.5" narrow slot black duct with no mounting holes. To order Adhesive-Backed Duct, add suffix A to Catalog Number. Example: TY75X15NPB6A is a .75" x 1.5" narrow slot black duct with adhesive backing. Shelf life for adhesive is 1 year. PVC vinyl duct is UL Recognized , CSA Certified and CE Compliant. I = Intrinsic Blue United States Tel: 901.252.8000 800.816.7809 Fax: 901.252.1354 Canada Tel: 450.347.5318 Fax: 450.347.1976 Technical Services Tel: 888.862.3289 www.tnb.com E-11 tnb06_wrtrm_sece_p26 8/9/07 1:06 PM Page E-26 and Accessories Technical Information and Accessories Ty-Duct ® meets all of the prominent agency approvals and standards. Agency Approvals: Thomas & Betts Ty-Duct wiring duct is UL recognized for all requirements set forth in UL standard 1565 “Positioning Device.” The Ty-Duct wiring duct meets all applicable requirements of the Canadian Standard Association as described in CSA C22.2 No. 18.5. All Ty-Duct wiring duct components comply with the European Directives for CE (Conformite European) Marking. All materials used in the making of the Ty-Duct wiring duct comply with the European Directives 2002/95/EC (RoHS), 2002/96/EC (WEEE), and 2003/11/EC. Standards: NFPA-79-2002 Thomas & Betts Ty-Duct wiring duct is compliant with the National Fire Protection Agency NFPA-79-2002. All materials used in the manufacturing of the Ty-Duct components are selected from flame-retardant material and comply with IEC 60332-1. The testing is required in order to comply with NFPA-79-2002, Section 13.3.1. UL 508/UL 508A As required in UL508/UL508A a factory-installed conductor shall be separated from a conductor used in a different circuit when the conductors are not insulated for the maximum voltage of either circuit. The Ty-Duct wiring duct with a divider wall creates the required separation to meet this requirement. DIN 43 659 This European standard specifies dimensions for slotted trunkings installed in electrical switchgear assemblies. The standard defines the following dimensions: • The mounting hole pattern • The mounting hole slot dimensions • The mounting hole pitch and location • The minimum overall product length E-26 www.tnb.com United States Tel: 901.252.8000 800.816.7809 Fax: 901.252.1354 Canada Tel: 450.347.5318 Fax: 450.347.1976 Technical Services Tel: 888.862.3289 Item # 26 Model C12-17 Combustible Gas Transmitter....... Units supplied with the integral display also contain a single alarm setpoint and relay for local alarm purposes. This integral relay is a latching alarm that can be reset with a magnetic tool without opening the enclosure. C12-17 transmitters can be connected directly to PLC, DCS, or computer based alarm systems without additional hardware. If complete alarm systems are needed, ATI can supply Series B14 modular alarm receivers or Series C14 Multi-point scanning alarm units to provide all required alarm functions. Sensor Operation Transmitter with display The Model C12-17 is a stand-alone gas transmitter designed to detect potentially hazardous concentrations of combustible gases in ambient air. Gases and hydrocarbon vapors such as methane, propane, butane, gasoline, toluene, hydrogen, and many others can be reliably monitored in process buildings, analyzer enclosures, pump stations, and gas compressor stations. In fact, anywhere gases or vapors may build up to explosive levels can be readily monitored using this transmitter. C12-17 Combustible Gas Transmitters are three-wire transmitters, operating from 24 VDC power supplies and transmitting a 4-20 mA signal proportional to 0-100% LEL (Lower Explosive Limit) of a particular gas or vapor. The transmitter is available either as a blind transmitter or with integral LCD display that provides local indication of gas concentration, visible through the glass window in the explosion-proof housing. Combustible gas sensors are made up of two matched sensing elements, one active and one passive. Both are electrically heated and form two legs of a Wheatstone bridge circuit. When combustible gas contacts the sensor, the active element catalyzes the oxidation of gas, heating the active element and changing it's resistance. The passive element remains unchanged, resulting in a change in the bridge circuit that is proportional to the gas concentration. Explosion-proof sensor assemblies are made of 316 stainless steel for maximum corrosion protection. A sinter bonded flame arrestor provides the gas diffusion path to the sensing elements while maintaining the flame-proof integrity of the assembly. Sensing elements are specially designed for maximum poison resistance and long life in harsh industrial environments, with sensor life typically 2 years or more. Model C12-17 Combustible Gas Transmitter... .... Specifications Gas Type: Display: Range: Response Time (T90): Accuracy: Electronic Repeatability: Electronic Linearity: Zero Drift: Span Drift: Output: Calibrated for methane unless otherwise ordered. 3-digit LCD optional 0-100% LEL 10 seconds Power: Enclosure: Generally ±5% of value, but limited by available calibration gas accuracy. ±1% Sensor: Controls: Alarm: Alarm Relay: ±0.5% Less than 2% full scale per month Less than 3% per month Powered 4-20 mA, 675 ohms maximum at 24 VDC Operating Temperature: Weight: 12-30 VDC, 100 mA maximum Explosion-proof, Class 1, Div 1, Groups B, C, &D Optional single alarm available SPDT, 5 Amp @ 220 VAC non-inductive, latching 316 stainless steel Potentiometer zero and span adjustment Potentiometer alarm setpoint adjustment Magnetic reset switch for latching alarm relay -40° to +70°C 3 lbs (1.3 kg) Ordering Information: Model C12-17-DDDD-E-F Suffix DDDD - Range 0100 - 0-100% LEL 0050 - 0-50% LEL Suffix C - Sensor Style 1 - Standard 2 - Remote sensor with junction box Suffix E - Units of Measurement 1 - No display 2 - Integral display & alarm relay Accessories 00-0258 - Calibration adapter 00-0261 - Splash guard/remote calibration adapter 00-0298 - Sensor flow assembly Transmitter without display Represented By: Analytical Technology, Inc. 6 Iron Bridge Drive • Collegeville, PA 19426 Phone: 610/917-0991• Toll-Free: 800/959-0299 Fax: 610/917-0992 E-Mail: [email protected] Web: www.analyticaltechnology.com ATI (UK) Limited Bank Chambers, 33 Stamford Street Mossley, Aston-u-Lyne OL5 0LL Phone: +44 (0) 1457 832800 Fax: +44 (0) 1457 83950 E-Mail: [email protected]
© Copyright 2024 ExpyDoc