Page 1 / 6 Certificate number: 20125/B0 BV File number: ACE 02/010/20 Product code: 2633H This certificate is not valid when presented without the full attached schedule composed of 7 sections www.veristar.com TYPE APPROVAL CERTIFICATE This certificate is issued to ABB SpA - ABB Sace Division Frosinone - ITALY for the type of product CIRCUIT BREAKERS (LOW VOLTAGE) Low voltage moulded-case circuit-breakers Tmax type T1, T2, T3, T4, T5, T6, T7 Requirements: Bureau Veritas Rules for the Classification of Steel Ships. IEC 60947-1 (2007), IEC 60947-2 (2006). This certificate is issued to attest that BUREAU VERITAS did undertake the relevant approval procedures for the product identified above which was found to comply with the relevant requirements mentioned above. This certificate will expire on: 04 Dec 2019 For BUREAU VERITAS, At BV GENOA, on 04 Dec 2014, Gianni Pirovano This certificate remains valid until the date stated above, unless cancelled or revoked, provided the conditions indicated in the subsequent page(s) are complied with and the product remains satisfactory in service. This certificate will not be valid if the applicant makes any changes or modifications to the approved product, which have not been notified to, and agreed in writing with BUREAU VERITAS. Should the specified regulations or standards be amended during the validity of this certificate, the product(s) is/are to be re-approved prior to it/they being placed on board vessels to which the amended regulations or standards apply. This certificate is issued within the scope of the General Conditions of BUREAU VERITAS Marine & Offshore Division available on the internet site www.veristar.com. Any Person not a party to the contract pursuant to which this document is delivered may not assert a claim against BUREAU VERITAS for any liability arising out of errors or omissions which may be contained in said document, or for errors of judgement, fault or negligence committed by personnel of the Society or of its Agents in establishment or issuance of this document, and in connection with any activities for which it may provide. The electronic version is available at: http://www.veristarnb.com/veristarnb/jsp/viewPublicPdfTypec.jsp?id=8oonhtlszn BV Mod. Ad.E 530 October 2014 This certificate consists of 6 page(s) Page 2 / 6 Certificate number: 20125/B0 BV THE SCHEDULE OF APPROVAL 1. PRODUCT DESCRIPTION: Technical data of low voltage moulded case circuit-breakers Tmax type: T1, T2, T3, T4, T5, T6, T7. - Rated insulation voltage, Ui - Rated impulse withstand voltage, Uimp: - Rated frequency - Poles : 1000V : 8 kV : 50 - 60 Hz : 3/4 Rated uninterrupted current , Iu (A) Rated service voltage, Ue (AC) (V) (DC) (V) Rated ultimate short-circuit breaking capacity, Icu 220/230 V AC (kA) 380/415 VAC (kA) 440 V AC (kA) 500 V AC (kA) 690 V AC (kA) Rated service short-circuit breaking capacity, Ics 220/230 V AC (% Icu) 380/415 VAC (% Icu) 440 V AC (%Icu) 500 V AC (% Icu) 690 V AC (%Icu) Utilization category Rated short-circuit making capacity, Icm 220/230 V AC (kA) 380/415 V AC (kA) 440 V AC (kA) 500 V AC (kA) 690 V AC (kA) Version Rated uninterrupted current , Iu (A) Rated service voltage, Ue (AC) (V) (DC) (V) Rated ultimate short-circuit breaking capacity, Icu 220/230 V AC (kA) 380/415 VAC (kA) 440 V AC (kA) 500 V AC (kA) 690 V AC (kA) Rated service short-circuit breaking capacity, Ics 220/230 V AC (%Icu) 380/415 VAC (%Icu) 440 V AC (%Icu) 500 V AC (%Icu) 690 V AC (%Icu) Utilization category Rated short-circuit making capacity, Icm 220/230 V AC (kA) 380/415 V AC (kA) 440 V AC (kA) 500 V AC (kA) 690 V AC (kA) Version Tmax T1 B 160 690 500 C 160 690 500 N 160 690 500 25 16 10 8 3 40 25 15 10 4 50 36 22 15 6 100% 100% 100% 100% 100% A 75% 100% 75% 75% 75% A 75% 75% 50% 50% 50% A 52,5 32 17 13,6 4,3 F 84 52,5 30 17 5,9 F 105 75,6 46,2 30 9,2 F Tmax T2 N 160 690 500 S 160 690 500 H 160 690 500 L 160 690 500 65 36 30 25 6 85 50 45 30 7 100 70 55 36 8 120 85 75 50 10 100% 100% 100% 100% 100% A 100% 100% 100% 100% 100% A 100% 100% 100% 100% 100% A 100% 75% (70 kΑ) 75% 75% 75% A 143 75,6 63 52,5 9,2 F-P 187 105 94,5 63 11,9 F-P 220 154 121 75,6 13,6 F-P 264 187 165 105 17 F-P The electronic version is available at: http://www.veristarnb.com/veristarnb/jsp/viewPublicPdfTypec.jsp?id=8oonhtlszn BV Mod. Ad.E 530 May 2009 This certificate consists of 6 page(s) Page 3 / 6 Certificate number: 20125/B0 BV Tmax T3 N 250 690 500 Rated uninterrupted current , Iu (A) Rated service voltage, Ue (AC) (V) (DC) (V) Rated ultimate short-circuit breaking capacity, Icu 220/230 V AC (kA) 380/415 VAC (kA) 440 V AC (kA) 500 V AC (kA) 690 V AC (kA) Rated service short-circuit breaking capacity, Ics 220/230 V AC (%Icu) 380/415 VAC (%Icu) 440 V AC (%Icu) 500 V AC (%Icu) 690 V AC (%Icu) Utilization category Rated short-circuit making capacity, Icm 220/230 V AC (kA) 380/415 V AC (kA) 440 V AC (kA) 500 V AC (kA) 690 V AC (kA) Version Rated uninterrupted current , Iu (A) Rated service voltage, Ue (AC) (V) (DC) (V) Rated ultimate short-circuit breaking capacity, Icu 220/230 V AC (kA) 380/415 VAC (kA) 440 V AC (kA) 500 V AC (kA) 690 V AC (kA) Rated service short-circuit breaking capacity, Ics 220/230 V AC (%Icu) 380/415 VAC (%Icu) 440 V AC (%Icu) 500 V AC (%Icu) Utilization category Rated short-circuit making capacity, Icm 220/230 V AC (kA) 380/415 V AC (kA) 440 V AC (kA) 500 V AC (kA) 690 V AC (kA) Version S 250 690 500 50 36 25 20 5 85 50 40 30 8 75% 75% 75% 75% 75% A 50% 50% (27kΑ) 50% 50% 50% A 105 75,6 52,5 40 7,7 F-P 187 105 84 63 13,6 F-P Tmax T4 N S 250/320 250/320 690 690 750 750 H 250/320 690 750 L 250/320 690 750 V 250/320 690 750 70 36 30 25 20 85 50 40 30 25 100 70 65 50 40 200 120 100 85 70 200 200 180 150 80 100% 100% 100% 100% A 100% 100% 100% 100% A 100% 100% 100% 100% A 100% 100% 100% 100% A 100% 100% 100% 100% A 154 75,6 63 52,5 40 F-P-W 187 105 84 63 52,5 F-P-W 220 154 143 105 84 F-P-W 440 264 220 187 154 F-P-W 660 440 396 330 176 F-P-W The electronic version is available at: http://www.veristarnb.com/veristarnb/jsp/viewPublicPdfTypec.jsp?id=8oonhtlszn BV Mod. Ad.E 530 May 2009 This certificate consists of 6 page(s) Page 4 / 6 Certificate number: 20125/B0 BV Rated uninterrupted current , Iu (A) Rated service voltage, Ue (AC) (V) (DC) (V) Rated ultimate short-circuit breaking capacity, Icu 220/230 V AC (kA) 380/415 VAC (kA) 440 V AC (kA) 500 V AC (kA) 690 V AC (kA) Rated service short-circuit breaking capacity, Ics 220/230 V AC (%Icu) 380/415 VAC (%Icu) 440 V AC (%Icu) 500 V AC (%Icu) 690 V AC (%Icu) Utilization category *) Rated short-circuit making capacity, Icm 220/230 V AC (kA) 380/415 V AC (kA) 440 V AC (kA) 500 V AC (kA) 690 V AC (kA) Version Tmax T5 N S 400/630 400/630 690 690 750 750 H 400/630 690 750 L 400/630 690 750 V 400/630 690 750 70 36 30 25 20 85 50 40 30 25 100 70 65 50 40 200 120 100 85 70 200 200 180 150 80 100% 100% 100% 100% 100% B(400A) -A(630A) 100% 100% 100% 100% 100% B(400A) -A(630A) 100% 100% 100% 100% 100% B(400A) -A(630A) 100% 100% 100% 100% 100% B(400A) -A(630A) 100% 100% 100% 100% 100% B(400A) -A(630A) 154 75,6 63 52,5 40 F-P-W 187 105 84 63 52,5 F-P-W 220 154 143 106 84 F-P-W 440 264 220 187 154 F-P-W 660 440 396 330 176 F-P-W Tmax T6 Rated current, Iu (A) Rated service voltage, Ue (AC) (V) (DC) (V) Rated ultimate short-circuit breaking capacity, Icu 220/230 V AC (kA) 380/415 V AC (kA) 440 V AC (kA) 500 V AC (kA) 690 V AC (kA) Rated service short-circuit breaking capacity, Ics 220/230 V AC (%Icu) 380/415 V AC (%Icu) 440 V AC (%Icu) 500 V AC (%Icu) 690 V AC (%Icu) Utilization category **) Rated short-circuit making capacity, Icm 220/230 V AC (kA) 380/415 V AC (kA) 440 V AC (kA) 500 V AC (kA) 690 V AC (kA) Version N 630/800/1000 690 750 S 630/800/1000 690 750 H 630/800/1000 690 750 L 630/800/1000 690 750 70 36 30 25 20 85 50 45 35 22 100 70 50 50 25 200 100 80 65 30 100% 100% 100% 100% 75% B(630A-800A) -A(1000A) 100% 100% 100% 100% 75% B(630A-800A) -A(1000A) 100% 100% 100% 100% 75% B(630A-800A) -A(1000A) 75% 75% 75% 75% 75% B(630A-800A) -A(1000A) 154 75,6 63 52.5 40 F-W 187 105 94.5 73.5 46 F-W 220 154 105 105 52.5 F-W 440 220 176 143 63 F-W The electronic version is available at: http://www.veristarnb.com/veristarnb/jsp/viewPublicPdfTypec.jsp?id=8oonhtlszn BV Mod. Ad.E 530 May 2009 This certificate consists of 6 page(s) Page 5 / 6 Certificate number: 20125/B0 BV Tmax T7 Rated current, Iu (A) Rated service voltage, Ue (AC) (V) (DC) (V) Rated ultimate short-circuit breaking capacity, Icu 220/230 V AC (kA) 380/415 V AC (kA) 440 V AC (kA) 500 V AC (kA) 690 V AC (kA) Rated service short-circuit breaking capacity, Ics 220/230 V AC (%Icu) 380/415 V AC (%Icu) 440 V AC (%Icu) 500 V AC (%Icu) 690 V AC (%Icu) Utilization category ***) Rated short-circuit making capacity, Icm 220/230 V AC (kA) 380/415 V AC (kA) 440 V AC (kA) 500 V AC (kA) 690 V AC (kA) Version S 800/1000/ 1250/1600 690 - H 800/1000/ 1250/1600 690 - L 800/1000/ 1250/1600 690 - V (7) 800/1000/ 1250/1600 690 - 85 50 50 40 30 100 70 65 50 42 200 120 100 85 50 200 150 130 100 60 100% 100% 100% 100% 100% B 100% 100% 100% 100% 75% B 100% 100% 100% 75% 75% B 100% 100% 100% 100% 75% B 187 105 105 84 63 F-W 220 154 143 105 88,2 F-W 440 264 220 187 105 F-W 440 330 286 220 132 F-W *) Icw = 5 kA, **) Icw = 7,6 kA (630 A) - 10 kA (800 A), ***) Icw = 20 kA (S, H, L version) - 15 kA (V version). F = Front, P = Plug-in circuit-breakers, W = Withdrawable circuit-brakers. Trip units: Thermomagnetic: T adjustable, M fixed T adjustable, M adjustable (5..!0 x In) T adjustable, M fixed (3..5 x In) T adjustable, M adjustable (2,5..5 x In) Magnetic only Electronic: PR221DS PR222DS PR223DS PR231/P PR232/P PR331/P PR332/P TMD TMA TMG TMG T1 T2 T3 T4 T5 T6 T7 X - X X X(1) X X X X(2) X(3) X X(4) X(5) - X(6) - - X - - X X X - X X X - X X X - X X X X - (1) - MF up to In 12,5 A, (2) - up to 50 A, (3) - up to 250 A, (4) - up to 500 A, (5) - up to 500 A, (6) - up to 800 A (W version is not available on T6 1000 A), (7) - only for T7 800/1000/1250 A. The electronic version is available at: http://www.veristarnb.com/veristarnb/jsp/viewPublicPdfTypec.jsp?id=8oonhtlszn BV Mod. Ad.E 530 May 2009 This certificate consists of 6 page(s) Page 6 / 6 Certificate number: 20125/B0 BV 2. DOCUMENTS AND DRAWINGS: As per Manufacturer's technical catalogue N° 1SDC210015D0202. 3. TEST REPORTS: ABB SACE test reports Nos LBRP 8013/00 issued on 08.09.2008 and LBRP 7876/01 issued on 20.12.2007. Intertek test reports Nos E 133S220765_25a, E 133S220765_25aR, E 133S220765_25b and E 133S220765_25bR issued on 28.06.2007. CESI test report No A7027438 issued on 26.02.2008. LOVAG Certificates of Conformity Nos: IT 07.001 to IT 07.014, IT 07.040 ; IT 07.062, IT 07.075 to IT 07.078, IT 08.009, IT 08.010, IT 08.018 to IT 08.020, IT 08.051 to IT 08.054, IT 08.074, IT 08.075, IT 08.078 and IT 08.079 including performance test reports. 4. APPLICATION / LIMITATION: 4.1 - Approval also valid for ships to be granted with the notations: AUT-UMS, AUT-CCS, AUT-PORT and AUT-IMS. 4.2 - According to BV Rules for the Classification of Steel Ships and IEC 60947-2. 5. PRODUCTION SURVEY REQUIREMENTS: 5.1 - The above products are to be supplied by ABB SACE S.p.A. in compliance with the type described in this certificate. 5.2 - This type of product is within the category HBV of Bureau Veritas Rule Note NR320. 5.3 - ABB SACE S.p.A. has to make the necessary arrangements to have its works recognised by Bureau Veritas in compliance with the requirements of NR320 for HBV products : ABB SACE S.p.A. ABB Xinhui Low Voltage Switchgear CO., Ltd Via Baloni 35 Jinguzhou Industrial Development Zone, Xinhui District, I-24123 Bergamo, Italy Jiangmen City, Guangdong Province, P.R. China 6. MARKING OF PRODUCT: According to IEC 60947-2 specifications. 7. OTHERS: 7.1 - This approval is given on the understanding that the Society reserves the right to require check tests to be carried out on the units at any time and that ABB SACE S.p.A. - Bergamo - Italy will accept full responsibility for informing shipbuilders, shipowners or their sub-contractors of the proper methods of use and general maintenance of the units and the conditions of this approval. 7.2 - This Certificate supersedes the Type Approval Certificate No.20125/A1 BV issued on 14 Apr 2012 by the Society. *** END OF CERTIFICATE *** The electronic version is available at: http://www.veristarnb.com/veristarnb/jsp/viewPublicPdfTypec.jsp?id=8oonhtlszn BV Mod. Ad.E 530 May 2009 This certificate consists of 6 page(s)
© Copyright 2024 ExpyDoc