CERT140286 Goliath GP Type SL 14030061

STANDARD CEMENT CERTIFICATE
FINAL
Cement Australia
PO Box 1328
Milton QLD 4064
Australia
Telephone: +61 7 3335 3000
Fax:
+61 7 3335 3222
Prior Reports: None
Certificate Number: CERT140286
Issued: 15, April 2014
Product being certified:
Product sample date:
Sample Identification:
Description:
Testing Conditions:
Goliath GP
03-Mar-2014
Sample Code: 14030061
Grab Sample from Despatch Silo - Melbourne Despatch
As received at Cement Australia Darra Laboratory,
12 Station Avenue, Darra Queensland 4076 Australia. Testing commenced on 04-Mar-14
Test Results
Fineness Index
Test
Result
Standard
AS 3972:2010 Limit
Test
Result
Standard
AS 3972:2010 Limit
Test
Result
Standard
AS 3972:2010 Limit
m2/kg
385
Residue 45µm
Sieve
%
5.6
Normal
Consistency
%
26.7
Setting Time
Initial
min
120
Setting Time
Final
min
180
Soundness1
mm
0
Loss on
Ignition
%
3.8
AS/NZS 2350.8:2006 AS/NZ 2350.9-2006 AS/NZS 2350.3:2006 AS/NZS 2350.4:2006 AS/NZS 2350.4:2006 AS/NZS 2350.5:2006 AS/NZS 2350.2-2006
None
None
None
45min Minimum
360min Maximum
5mm Maximum
None
Na2O
Equivalent
%
0.6
CaO
SiO2
Al2O3
Fe2O3
SO3
MgO
by XRF
by XRF
by XRF
by XRF
by XRF
by XRF
%
63.9
%
20.0
%
4.4
%
2.8
%
2.7
%
1.4
AS/NZ 2350.2-2006 AS/NZ 2350.2-2006 AS/NZ 2350.2-2006 AS/NZ 2350.2-2006 AS/NZ 2350.2-2006 AS/NZ 2350.2-2006 AS/NZ 2350.2-2006
None
None
None
None
3.5% Maximum
None
None
16 wk Sulfate
Resistance
µStrain
Not Tested
Total Chloride
by XRF
%
0.025
Mortar Compressive Strength
3 Days
7 Days
28 Days
MPa
MPa
MPa
40.4
48.5
58.3
Shrinkage
28 Days
µStrain
650
AS/NZS2350.11:2006
AS/NZ 2350.13-2006
AS2350.7-2006
AS2350.14-2006
AS/NZS 2350.2:2006
750µStrain Max.
Not Tested
Not Tested
0.1% Maximum
None
35MPa Minimum
45MPa Minimum
Peak Temp Rise
°c
Not
hrs
Tested
This sample conforms to the following requirements of AS 3972:2010
Type GP
Type GB
Type HE
Type LH
Type SL
Type SR
Contains up to 7.5% Limestone mineral addition.
Mineral Additions:
Minor Additional Constituents: Nil
Approved Signatory
V Connell
Chemical Testing
Construction Materials Testing
This document is issued in accordance with
NATA’s accreditation requirements.
Accredited for compliance with ISO/IEC
17025. The results of the tests, calibrations
and/or measurements included in this
document are traceable to
Australian/national standards.
NATA Accredited Laboratory Numbers
187 188
Notes:
1. Variation AS/NZS 2350.5:2006- Section 5(c) Cooling accelerated
after boiler.
*14030061*
*CERT140286*
DA-SF-014
This test report shall not be reproduced except in full, without written approval from Cement Australia.
Page 1 of 1