HVFS series Series HVFS 1 HVFS terminal units with fan CONTENTS Description Versions and dimensions Technical data 2 3 8 2 Series HVFS HVFS terminal units with fan Description The HVFS terminal unit is a solution that fully adapts to installations in which it is desirable to retain the flexibility of a variable air volume (VAV) system, while also providing a constant air volume to specific areas (VAC). When the thermal demands in the conditioned space are highest, the flow rate supplied by the HVFS air terminal is 100% primary air, an action that is controlled by the volume control damper. The HVFS boxes include the following: - Double-inlet fan with built-in single-phase motor, with adjustable speed drive. - Differential pressure sensor at the primary air inlet. - Actuator-Belimo NMV-D2M volume control damper, at the primary air inlet. - Airtight volume control damper, manufactured of galvanized steel sheet, that runs at low pressure. - Return air inlet with acoustic silencer at inlet. - Fiberglass insulation with a thickness of 50 mm on the inner surface of the box enclosure. As the thermal needs of the conditioned space gradually decrease, the primary air intake to the air terminal also gradually decreases and the secondary air intake increases proportionally. The air flow supplied by the fan to the diffusers remains constant, whereas the temperature changes according to thermal demand. The HVFS boxes control the supply air temperature by varying the primary air intake (characteristic of a VAV system), while the supply flow to the rooms remain constant (characteristic of a VAC system). The HVFSW and HVFSE air terminals include a hot-water or electric coil, respectively, when necessary to combat negative loads (winter), e.g., perimeter loads or in the cases of prolonged shutdown of the installation. In these cases, the primary air intake is low, ensuring a minimal ventilation air supply. The HVFS terminal unit comes in 7 sizes, covering an air flow range of 300 to 6200 m3/h. The HVFS terminal units are serviced from the outside, with no need to remove the unit; the fan motor assembly may be removed through the lower panel, and the control elements from one side of the unit. Series HVFS Versions. Dimensions HVFS BOX 300 to 1500 3 4 Versions. Dimensions HVFS BOX 2000 to 3000 Series HVFS Series HVFS Versions. Dimensions HVFSW BOX 300 to 1500 5 6 Versions. Dimensions HVFSW BOX 2000 to 3000 Series HVFS Series HVFS 7 Versions. Dimensions Dimension table - HVFS 300 to 1500 boxes MODEL A B C D E F G H I J K HVFS-300 HVFS-500 HVFS-750 HVFS-1000 HVFS-1500 277 379 442 Ø 158 Ø 198 198 198 198 325 390 390 425 475 104 260 260 260 289 605 790 790 915 1100 250 250 250 250 250 250 300 300 350 500 215 232 300 300 333 320 480 480 480 560 255 415 415 415 455 1150 1150 1150 1150 1180 3 MODEL DAMP. FAN FLOW RATE m /h HVFS-300 HVFS-500 HVFS-750 HVFS-1000 HVFS-1500 400 800 1200 1600 2000 D2E-133-DM47 DA 9/7 RE DA 9/9 RE DA 9/9 RE DA 10/10 RE 510 850 1270 1700 2500 Dimension table - HVFS 2000-3000 boxes MODEL B C D E F G H I J K HVFS-2000 HVFS-3000 Ø 348 Ø 400 262 262 260 289 1200 1220 250 300 475 800 300 333 480 560 415 455 1180 1180 MODEL DAMP. FAN POL. W FLOW RATE m /h HVFS-2000 HVFS-3000 450 575 2xDA 9/9 RE 2xDA 10/10 RE 6 6 240 370 - 3 Dimension table - HVFSW 300 to 1500 boxes MODEL A B C D E F G H I J K HVFSW-300 HVFSW-500 HVFSW-750 HVFSW-1000 HVFSW-1500 277 379 442 Ø 158 Ø 198 198 198 198 325 390 390 425 475 104 260 260 260 289 605 790 790 915 1100 250 250 250 250 250 250 300 300 350 500 215 232 300 300 333 320 480 480 480 480 255 415 415 415 455 1350 1450 1450 1450 1450 MODEL DAMP. POLES POT. MODEL HVFSW-300 HVFSW-500 HVFSW-750 HVFSW-750 HVFSW-1000 HVFSW-1500 400 800 1200 1200 1600 2000 6 6 6 6 6 175 W 130 W 240 W 240 W 240 W 370 W D2E-133-D47 DA 9/7 RE DA 9/9 RE DA 10/10 RE DA 10/10 RE DA 10/10 RE FAN 3 REHEAT COIL FLOW RATE m /h BC-3T-3F-360 BC-6T-3F-545 BC-6T-3F-545 BC-6T-3F-545 BC-6T-3F-670 BC-6T-3F-805 510 850 1200 1200 1600 2500 Dimension table - HVFSW 2000-3000 boxes MODEL A C D E F G H I J K HVFSW-2000 HVFSW-3000 Ø 348 Ø 400 262 262 260 289 1140 1220 250 300 475 800 300 333 480 480 415 455 1450 1450 MODEL DAMP. HVFSW-2000 HVFSW-3000 L=450 L=575 POLES 6 6 FAN POT. 240 W 370 W MODEL 2xDA 10/10 RE 2xDA 10/10 RE 3 REHEAT COIL FLOW RATE m /h BC-6T-3F-845 BC-6T-3F-925 3400 5000 Series HVFS 8 Technical data Radiated noise. Sound power level dB(A). Minimum pressure (air inlet) Size 3000 3000 3000 3000 3000 3000 3000 3 Q [l/s] Q [m /h] 63 125 250 500 1k 2k 4k 8k 86,1 113,9 141,7 169,4 141,7 188,9 236,1 283,3 211,1 283,3 352,8 425 283,3 377,8 472,2 566,7 425 566,7 708,3 850 566,7 755,6 944,4 1133,3 850 1133,3 1416,7 1700 310 410 510 610 510 680 850 1020 760 1020 1270 1530 1020 1360 1700 2040 1530 2040 2550 3060 2040 2720 3400 4080 3060 4080 5100 6120 < < < < < < < < 7 < < < < < < < < < < 21 < < < 22 < < 23 26 < 22 26 29 < 23 27 30 < 23 27 30 < 23 27 30 21 25 29 32 22 26 30 33 25 30 34 37 21 26 30 33 22 27 30 33 22 27 31 34 22 27 30 34 24 29 33 36 25 30 34 37 29 34 38 41 20 24 28 31 20 25 28 31 20 25 29 32 20 25 29 32 22 27 31 34 24 28 32 35 27 32 36 39 < < 22 25 < < 23 26 < 20 23 26 < < 23 26 < 22 25 29 < 23 27 30 21 26 30 33 < < 20 23 < < 20 24 < < 21 24 < < 21 24 < < 23 26 < 20 24 27 < 24 28 31 < < < 21 < < < 21 < < < 22 < < < 21 < < 21 24 < < 22 25 < 22 25 28 < < < < < < < < < < < < < < < < < < < 22 < < < 23 < < 23 26 Regenerated noise. Sound power level dB(A). Minimum pressure (air inlet) Octave bands [Hz] Size 300 500 750 1000 1500 2000 3000 Q [l/s] 3 Q [m /h] 63 125 250 500 1k 2k 4k 8k 86,1 113,9 141,7 169,4 141,7 188,9 236,1 283,3 211,1 283,3 352,8 425 283,3 377,8 472,2 566,7 425 566,7 708,3 850 566,7 755,6 944,4 1133,3 850 1133,3 1416,7 1700 310 410 510 610 510 680 850 1020 760 1020 1270 1530 1020 1360 1700 2040 1530 2040 2550 3060 2040 2720 3400 4080 3060 4080 5100 6120 < < < < < < < < < < < < < < < < < < < < < < < < < < < 20 < 21 24 27 < 21 25 28 < 22 25 28 < 21 25 28 < 24 28 31 20 25 29 32 24 28 32 35 27 32 35 38 27 32 36 39 27 32 36 39 27 32 36 39 30 35 38 41 31 36 39 43 34 39 43 46 26 30 34 37 26 31 35 38 26 31 35 38 26 31 35 38 29 33 37 40 30 35 38 41 33 38 42 45 < < 22 25 < < 22 25 < < 23 26 < < 23 26 < 21 25 28 < 22 26 29 21 26 30 33 < < < < < < < 20 < < < 20 < < < 20 < < < 22 < < 20 23 < 20 24 27 < 20 24 27 < 20 24 27 < 21 25 28 < 21 24 27 < 23 27 30 < 24 28 31 23 28 31 34 < 23 27 30 < 23 27 30 < 24 28 31 < 23 27 30 21 26 30 33 22 27 31 34 26 31 34 37 <: Sound power level <20 dB(A) Series HVFS 9 Technical data Overall radiated and regenerated sound levels. For minimal air inlet pressure Sound pressure level in dB(A) Size 300 500 750 1000 1500 2000 3000 Q [l/s] Q [m3/h] Radiated noise (dB(A)) Regenerated noise (dB(A)) 86,1 113,9 141,7 169,4 141,7 188,9 236,1 283,3 211,1 283,3 352,8 425 283,3 377,8 472,2 566,7 425 566,7 708,3 850 566,7 755,6 944,4 1133,3 850 1133,3 1416,7 1700 310 410 510 610 510 680 850 1020 760 1020 1270 1530 1020 1360 1700 2040 1530 2040 2550 3060 2040 2720 3400 4080 3060 4080 5100 6120 25 30 34 37 26 30 34 37 26 31 35 38 26 31 34 38 28 33 37 40 29 34 38 41 33 38 41 45 30 35 39 42 30 35 39 42 31 36 39 43 31 35 39 42 33 38 42 45 34 39 43 46 38 42 46 49 10 Series HVFS THIS CATALOGUE IS INTELLECTUAL PROPERTY. Reproduction, either partial or total, by any means, including electronic, is prohibited without prior written authorisation from KOOLAIR, S.A. CIN-HVFS-0114-00 Koolair S.A. Polígono Industrial 2 La Fuensanta 28936 Móstoles (Madrid) Tel 91 645 00 33 Fax 91645 69 62 www.koolair.com
© Copyright 2024 ExpyDoc