19299RevB140910_ViewRNA eZ Detection Kit Pkg

Package Insert
ViewRNA™ eZ Detection Kit 1-Plex
Cat. No. QVR0001
General Information
The ViewRNA eZ Detection Kit contains the universal reagents required to perform automated ViewRNA eZ in situ
hybridization (ISH) assays for RNA in formalin-fixed, paraffin-embedded (FFPE) tissue sections on slides with the Leica BOND
RX instrument. Each kit is configured for processing a minimum of 90 slides when 18 slides are assayed in each of
5 experiments. If fewer slides are processed per experiment, reagents shortages may occur before finishing the 90 slides.
Safety Warnings and Precautions
All chemicals should be considered potentially hazardous. We recommend that this product and its components be handled
by those trained in laboratory techniques and be used according to the principles of good laboratory practice.
Contents and Storage
The ViewRNA eZ Detection Kit contains the components listed in the table below. All components have a shelf life of
6 months from the date of receipt when stored as recommended.
IMPORTANT: Do not freeze ViewRNA eZ Detection Kit reagents.
Components
Part Number
Quantity
Storage
Amp 1
19287
1 x 30 mL
2 – 8 °C
Amp 2
19289
1 x 30 mL
2 – 8 °C
Amp 3
19292
1 x 30 mL
2 – 8 °C
Amp 4, 500X
19273
1 x 80 μL
2 – 8 °C
Amp 4 Diluent
19272
1 x 40 mL
2 – 8 °C
Red 1
19274
1 x 25 mL
2 – 8 °C
Red 2
19275
1 x 10 mL
2 – 8 °C
Rinse
19276
1 x 100 mL
2 – 8 °C
Probe Diluent
19271
1 x 40 mL
2 – 8 °C
Color-Coded Labels
19279
1 each
Quick Reference Card
19280
1
2
ViewRNATM eZ Detection Kit 1-Pex Package Insert
US Headquarters
Affymetrix, Inc.
3420 Central Expressway
Santa Clara, CA 95051
Tel: 1-888-362-2447
Direct: 1-408-731-5000
Fax: 1-408-731-5380
Email: [email protected]
Email: [email protected]
Email: [email protected]
European Headquarters
Panomics Srl
Via Sardegna 1
20060 Vignate-Milano (Italy)
Tel: +39-02-95-360-250
Fax: +39-02-95-360-992
Email: [email protected]
Email: [email protected]
Email: [email protected]
Asia Pacific Headquarters
Affymetrix Singapore Pte Ltd.
No.7 Gul Circle #2M-01/08
Keppel Logistics Building
Singapore 629563
Tel: +65-6395-7200
Fax: +65-6395-7300
Email: [email protected]
Email: [email protected]
Email: [email protected]
www.affymetrix.com/panomics
For research use only. Not for use in diagnostic procedures.
P/N 19299 Rev. B 140910
© 2014 Affymetrix, Inc. All rights reserved. Affymetrix® and QuantiGene® are registered trademarks of Affymetrix, Inc. All other trademarks are the property of their respective owners.