Power Supply Center (PSC) - Q-Tran

Power Supply Center (PSC)
Ordering and Specification Guidee
Q6M-DC
1
Max Lamp
Load (Watts)
Size
12VDC
60DC
24VDC
PSC
Efficiency
60W
Max Energy
Rating (Watts)
94
Max Prim.
Max PSC
Rating VA Amps @ 120V
78W
63VA
Max Prim.
Amps @ 277V
.90 A
.40 A
60DC
60W
94
78W
63VA
.90 A
100DC 100W
94
130W
106VA
1.4 A
2 Primary Voltage
120 (60Hz) 220 (50/60Hz) 230 (50/60Hz)
240 (50/60Hz)
3 Transformer Secondary Voltage
.40 A
.55 A
277 (60Hz)
12V
24V
4 Number of Breakers
Up to Two Secondary Circuit Breakers can be used
1-2
5 Secondary Breaker Amperage
AMPS
Max 12V Load
2.5
4
5
30W
48W
60W
Max 24V Load
60W
96W
120W
6 & 7 Options
BK Black Powder Coat
Finish
Ordering Example
Q6M60DC+CAP-120/12-1X5+CK-S
LOW VOLTAGE LIGHTING POWER SUPPLY
• SURFACE MOUNT ANY POSITION
• SUITABLE FOR DAMP LOCATIONS
• FOR SUPPLY CONNECTIONS USE WIRE RATED FOR AT LEAST 90 C
• SUITABLE FOR INDOOR USE ONLY
• COMPLIES WITH N.E.C. ARTICLE 411
• COMPLIES WITH UL STANDARD 2108
• ISOLATION TOROIDAL TRANSFORMER
• USE DIMMERS RATED FOR MAGNETIC LOW VOLTAGE LOAD
• 50/60 CYCLE A.C. ONLY
• MADE IN THE U.S.A.
Housing Dimensions
• 18-guage Welded Steel Enclosure:
11.0”L X 7.0”W X 4.5”D
• Door: 10.0”L X 7.0”W
• Color: White Powder Coating
• Knockouts: 6
Q-Tran, Inc. reserves the right to change product specifications at any
time without incurring obligations.
Toroidal Transformer - Duo Tap (DT)
• Primary Taps: 3
• Secondary Voltages: 11VDC, 12VDC, 13VDC, 22VDC or 24VDC, 26VDC
Loads may be connected to one (1) of the primary taps up to the full watt rating of the
PSC.
Primary Circuit Protection
Mounting
Six (6) - Plane Surface Mounting Design
• Primary Magnetic Circuit Breaker
• Primary Autoset Thermal Protector
1
2
3
4
5
6
Thermal protector will temporarily disconnect the primary if the transformer overheats
due to an overload or saturation from a faulty dimmer.
Secondary Circuit Protection
WALL
• Magnetic Circuit Breakers: 2
• Amps: 2.5A, 4A, 5A
Breakers are sized to the feed load per N.E.C. Article 411 (not to exceed 25 amps per
load). All wiring by the electrical contractor must be Class 1 compliant to N.E.C.
Toroidal Choke - “Debuzzing Coil”
A Choke (especially helpful when dimming) reduces noise and in-rush current. Choke
included is sized according to power supply.
6
© Q-Tran, Inc.
CEILING FLOOR
Standard - 6 plane surface mount
Standard - Rod suspension
(Two -3/8” threaded rods - Not included)
NOTE: Suspension rods are purchased separately and not
from Q-Tran, Inc.
See Voltage Drop Calculator
at our website.