Issued: 12/12 Supersedes: SR 4640 Standard Pump Cable Mixer Model 4640 Part Number No. of Cables Max. Cable Length (Ft) 94 20 59 1 100 HP Volts Ø Cable Size/ Nominal O.D. 4.0 Y 200 3 4G2.5+2x1.5 Y 230 3 " 1 130 Y 460 3 " 1 500 Y 575 3 " 1 775 0.69"-(17.5 mm) See last page for break down of conductors used in one cable. 4/11 SUBCAB - Metric CABLE SIZE/ NOMINAL DIA. PART NUMBER CONDUCTORS (IN ONE CABLE) S12 X 1.5 30.0 mm (1.18") 94 08 94 (12) 1.5 mm2 (CTRL) S24 X 1.5 36.0 mm (1.42") 94 08 95 (24) 1.5 mm2 (CTRL) 4 G 50 43mm (1.69") 94 20 66 (3) 50 mm2 (PWR) (1) 50 mm2 (GND) 4 G 70 47mm (1.85") 94 20 67 (3) 70 mm2 (PWR) (1) 70 mm2 (GND) 4 G 95 56mm (2.2") 94 20 68 (3) 95 mm2 (PWR) (1) 95 mm2 (GND) 4 G 120 58mm (2.3") 94 20 69 (3) 120 mm2 (PWR) (1) 120 mm2 (GND) (PWR) = Power (GND) = Ground Issued: 10/14 Supersedes: General SUBCAB is manufactured to Flygt specifications and in accordance with international standards (IEC). Ratings Voltage - 750 volts; Current - determined by size of conductors; Temperature - 90° C total, based on a 40° C ambient. Materials Jacket - chlorinated polyethylene rubber; Conductor insulation - ethylene propylene rubber (EPR). Coding Power conductors - black, blue or grey, brown; Ground conductors - green/yellow; Cables with more than 4 conductors will have all conductors colored black with white numbers printed on them. Approvals Factory mutual. CSA (CTRL) = Control IEC CABLE CODE 4 G 70 Size of conductor in square millimeters. "G" indicates that one of the conductors is a ground wire (green/yellow). "X" indicates no ground wire in cable. Total number of conductors in cable Metric wire sizes are expressed as millimeters squared. This is the cross-sectional area of the copper conductor. Metric to AWG Conversion mm2 1.5 2.5 4 6 10 16 25 35 50 70 70 95 120 150 185 AWG or kcmil 16 14 12 10 8 6 4 2 1 1/0 2/0 3/0 4/0 300kcmil 350kcmil Issued: 10/14 Supersedes: 10/12 Power Cable - cross reference Standard - Unshielded Cable Part Number Cable Size/ Nominal O.D. Conductors Part Number 14/4 94 21 01 4G2.5 0.51"-(13.0 mm) (3) 2.5 mm2 (PWR) (1) 2.5 mm2 (GND) 94 20 42 14/7 94 21 02 4Gx2.5+2x1.5 0.69"-(17.5 mm) (3) 2.5 mm2 (PWR) (1) 2.5 mm2 (GND) (2) 1.5 mm2 (CTRL) 12/4 94 21 03 4Gx4 0.65"-(16.5 mm) 12/7 94 21 04 10/4 Optional - Shielded Cable Cable Size/ Nominal O.D. Conductors Part Number S3x2.5+3x2.5/3+S(4x0.5) 0.75"-(19.0mm) (3) 2.5 mm2 (PWR) (3) 0.8 mm2 (GND) (4) 0.5 mm2 (CTRL) 94 19 90 94 20 59 " " (3) 4.0 mm2 (PWR) (1) 4.0 mm2 (GND) 94 20 43 S3x6+3x6/3+S(4x0.5) 0.83"-(21.0mm) 4G4+2x1.5 0.83"-(21.0 mm) (3) 4.0 mm2 (PWR) (1) 4.0 mm2 (GND) (2) 1.5 mm2 (CTRL) 94 20 60 " (3) 6.0 mm2 (PWR) (3) 2.0 mm2 (GND) (4) 0.5 mm2 (CTRL) " 94 21 05 4G6 0.73"-(18.5 mm) (3) 6.0 mm2 (PWR) (1) 6.0 mm2 (GND) 94 20 44 " " " 10/3-2-1-GC 94 21 06 4G6+2x1.5 0.94"-(24.0 mm) (3) 6.0 mm2 (PWR) (1) 6.0 mm2 (GND) (2) 1.5 mm2 (CTRL) 94 20 56 " " " 8/4 94 21 07 4G10+S(2x0.5) 0.98"-(25.0 mm) (3) 10.0 mm2 (PWR) (1) 10.0 mm2 (GND) (2) 0.5 mm2 (*CTRL) 94 19 81 S3x10+3x10/3+S(4x0.5) 0.98"-(25.0mm) (3) 10.0 mm2 (PWR) (3) 3.3 mm2 (GND) (4) 0.5 mm2 (CTRL) 8/3-2-1-GC 94 21 08 4G10+S(2x0.5) 0.98"-(25.0 mm) (3) 10.0 mm2 (PWR) (1) 10.0 mm2 (GND) (2) 0.5 mm2 (*CTRL) 94 19 81 " " 6/3-2-1-GC 94 21 09 4G16+S(2x0.5) 1.06"-(27.0 mm) (3) 16.0 mm2 (PWR) (1) 16.0 mm2 (GND) (2) 0.5 mm2 (*CTRL) 94 19 82 S3x16+3x16/3+S(4x0.5) 0.98"-(25.0mm) (3) 16.0 mm2 (PWR) (3) 5.3 mm2 (GND) (4) 0.5 mm2 (CTRL) 94 19 93 4/3-2-1-GC 94 21 10 4G25+S(2x0.5) 1.30"-(33.0 mm) (3) 25.0 mm2 (PWR) (1) 25.0 mm2 (GND) (2) 0.5 mm2 (*CTRL) 94 19 83 S3x25+3x16/3+S(4x0.5) 1.18"-(30.0mm) (3) 25.0 mm2 (PWR) (3) 5.3 mm2 (GND) (4) 0.5 mm2 (CTRL) 94 19 94 1/3-2-1-GC 94 21 11 3x50+2G35/2+S(2x0.5) 1.42"-(36.0 mm) (3) 50.0 mm2 (PWR) (2) 17.5 mm2 (GND) (2) 0.5 mm2 (*CTRL) 94 19 85 S3x50+3x25/3+S(4x0.5) 1.54"-(39.0mm) (3) 50.0 mm2 (PWR) (3) 8.3 mm2 (GND) (4) 0.5 mm2 (CTRL) 94 19 96 4G50 94 20 66 3x50+2G35/2+S(2x0.5) 1.42"-(36.0 mm) (3) 50.0 mm2 (PWR) (2) 17.5 mm2 (GND) (2) 0.5 mm2 (*CTRL) 94 19 85 4G70 94 20 67 3x70+2G35/2+S(2x0.5) 1.56"-(39.5 mm) (3) 70.0 mm2 (PWR) (2) 17.5 mm2 (GND) (2) 0.5 mm2 (*CTRL) 94 19 86 3x95+2G50/2+S(2x0.5) 1.91"-(48.5 mm) (3) 95.0 mm2 (PWR) (2) 25.0 mm2 (GND) (2) 0.5 mm2 (*CTRL) 94 19 87 3x120+2G70/2+S(2x0.5) 2.17"-(55.0 mm) (3) 120.0 mm2 (PWR) 94 19 88 (2) 35.0 mm2 (GND) (2) 0.5 mm2 (*CTRL) AWG** Metric 4G95 4G120 94 20 68 94 20 69 *Shielded **AWG cable no longer available. (in one cable) (in one cable) " 94 19 91 " 94 19 92 " S3x2.5+3x2.5/3+S(4x0.5) Shielded cable 3 Power conductors 2.5 mm2 conductor cross sectional area 3 Ground conductors 2.5/3 mm2 Ground conductor cross sectional area (per conductor) Shielded cable 4 Sensor conductors 0.5 mm2 conductor cross sectional area (PWR) = Power (GND) = Ground (CTRL) = Control
© Copyright 2024 ExpyDoc