QUICKTRONIC® Professional Series T5 & T5HO PROStart® Systems 28 T5, Universal Voltage (120-277V) Item OSRAM SYLVANIA Number Description Input Current Lamp (AMPS) Type 49181 QTP 2x28T5/UNV PSN (49180)* 49171 QTP 1x28T5/UNV PSN (49170)* 0.55/0.23 0.28/0.12 FP28T5 FP28T5 FP28T5 PROStart® QTP 28WT5 PSN models above also operate these lamps: FP14T5, FP21T5 & FP35T5 Rated Lumens No. of (lm) Lamps 2900 2900 2900 Ballast Input System Factor System Mean Power Efficacy2 (BF) Lumens Lumens (W) (lm/W) 2 1 1 1.00 1.00 1.00 5800 2900 2900 5395 2695 2695 65/63 89/92 32 90 32 90 BEF1 1.59 3.13 3.13 54 T5HO, Universal Voltage (120-277V) Item OSRAM SYLVANIA Number Description E L E C T R O N I C B A L L A S T S Input Current Lamp (AMPS) Type 49101 QTP 1x39-24T5HO/UNV PSN 0.23/0.10 (49100)* 0.36/0.15 49111 QTP 2x39-24T5HO/UNV PSN 0.47/0.20 (49110)* 0.76/0.32 49121 QTP 1x54T5HO/UNV PSN 0.51/0.21 (49120)* 49131 QTP 2x54T5HO/UNV PSN 1.00/0.43 (49130)* (49150)* QTP 1x80T5HO/UNV PSN 0.74/0.32 FP24T5HO FP39T5HO FP24T5HO FP24T5HO FP39T5HO FP39T5HO FP54T5HO FP54T5HO FP54T5HO FP80T5HO FT80T5DL Rated Lumens No. of (lm) Lamps 2000 1 3500 1 2000 2 2000 1 3500 2 3500 1 5000 1 5000 2 5000 1 7000 1 6000 1 Ballast Input System Factor System Mean Power Efficacy2 (BF) Lumens Lumens (W) (lm/W) 1.00 2000 1860 29 70 1.00 3500 3255 42 83 1.00 4000 3720 55/54 73/74 1.00 2000 1860 29 70 1.00 7000 6510 85/83 82/84 1.00 3500 3255 42 83 1.00 5000 4650 62/60 81/83 1.00 10,000 9300 121/118 83/85 1.00 5000 4650 61 82 1.00 7000 6510 90 78 1.0060005580 90 67 BEF1 3.45 2.38 1.85 3.45 1.20 2.38 1.67 0.85 1.64 1.11 1.11 54 T5HO, High Ambient Temperature (HT-90ºC max case temp) Universal Voltage (120-277V) QTP 2x54 T5HO Fixed Output 49136 QTP2x54T5HO/UNV PSN-HT (49135)* 1.00/0.43 0.96/0.41 0.89/0.38 0.53/0.24 0.50/0.21 0.45/0.21 FP54T5HO FP54/50W/SS FP54/47W/SS FP54T5HO FP54/50W/SS FP54/47W/SS 5000 5000 4575 5000 5000 4575 2 2 2 1 1 1 1.00 1.02 1.02 1.05 1.05 1.03 10,000 10,200 9335 5250 5250 4710 1.00 1.02 1.02 1.00 1.04 1.04 1.00 1.03 1.03 1.00 1.06 1.06 20,000 20,400 18,665 15,000 15,600 14,275 10,000 10,300 9425 5000 5300 4850 9300 121/118 9485 115/112 8680 106/103 4885 62/61 4885 59/58 4380 54/53 85 91 91 86 91 89 0.85 0.91 0.99 1.72 1.81 1.94 85 95 93 83 92 90 85 93 91 82 91 90 0.42 0.47 0.51 0.55 0.61 0.66 0.85 0.93 0.99 1.64 1.83 1.96 QTP 4x54 T5HO Switchable Model 49161 QTP4x54T5HO/UNV PSN-HTW (49160 discontinued) 2.05/0.90 1.85/0.80 1.72/0.75 1.51/0.65 1.46/0.62 1.34/0.58 1.00/0.45 0.95/0.42 0.88/0.39 0.51/0.25 0.50/0.25 0.47/0.25 FP54T5HO FP54/50W/SS FP54/47W/SS FP54T5HO FP54/50W/SS FP54/47W/SS FP54T5HO FP54/50W/SS FP54/47W/SS FP54T5HO FP54/50W/SS FP54/47W/SS 5000 5000 4575 5000 5000 4575 5000 5000 4575 5000 5000 4575 4 4 4 3 3 3 2 2 2 1 1 1 18,600 18,970 17,360 13,950 14,510 13,275 9300 9580 8765 4650 4930 4510 241/236 221/215 205/200 183/181 175/170 161/158 121/118 114/111 105/104 61/61 60/58 55/54 PROStart® QTP 54 T5HO PSN models above also operate these lamps: FT55DL, FPC55, L58 T5/T5HO at 35°C lamp ambient temperature (Item Number)* = Item Number/NAED in parentheses are models with leads/wires. No parenthesis = Ballasts with connectors only/no leads Ballasts operate additional lamp types. Complete performance data is in the Ballast Technology Applications & Specification Guide and at www.sylvania.com 1 Ballast Efficiency Factor (BEF) shown = (Ballast Factor x 100) divided by Input Power (Note: calculation based on lowest wattage value). 2 System Efficacy calculation based on lowest input power value unless otherwise noted. All data shown is for primary lamp types only. Complete data is available in the SYLVANIA QUICKTRONIC® Electronic Ballast Technology & Specification Guide and at www.sylvania.com Specifications subject to change without notice. OSRAM SYLVANIA National Customer Service and Sales Center 1-800-LIGHTBULB (1-800-544-4828) or www.sylvania.com 138
© Copyright 2025 ExpyDoc