EC RCV Series - roof mounted centrifugal fans The EC RCV series of roof mounted vertical discharge fans incorporates very high efficiency electronically commutated DC motors with on board infinitely variable control modules. These fans are AC powered with control and power conversion electronics integrated into the motor. Motor speeds can be controlled with 0-10V input signal or 10K potentiometer. The ability to control the speed at which the fan operates in response to real time ventilation demands is the basis of our energy saver range. Fan power consumption changes to the cube of speed reduction while air flow reduction stays proportional to reduced speed. This means that tailoring fan speed to meet exact air flow requirements has the potential to greatly reduce energy consumption through the removal redundant fan capacity. Construction Components are made from UV stabilised polymer, corrosion protected steel and fibreglass. All models are fitted with bird mesh as standard. Available in optional Colorbond™ colours. Testing Rated fan performance has been determined by testing to ISO 5801 Pt1 (1997). Fan sound data has been determined by testing to ISO 13347. Wiring Diagrams Refer to the latest product datasheet for individual model wiring instructions, data and specifications. Datasheets are available from our electronic selection software FansSelect downloadable at www.pacificHVAC.com It is a condition of our warranty that all equipment supplied is installed according to the requirements of AS/NZS3000:2007 Australian/New Zealand wiring rules. Suggested Specification The centrifugal fans shall be of the EC RCV series manufactured by Pacific HVAC Engineering Pty Ltd High performance backward curved centrifugal impellers shall be driven by EC motors incorporating on-board variable speed control. EC RCV Size A B C D E 190 265 215 410 250 70 8 280/315 395 345 515 300 70 10/12 355 500 400 630 395 70 11.9 400 500 400 630 410 70 15.1 450 720 620 910 510 80 25.2 500 720 620 910 510 80 35.7 560 720 620 910 515 80 41.2 630 810 710 1135 610 80 62.0 710 810 710 1135 650 80 79.0 Max kg Ancillaries All models shall be performance tested to ISO 5801 Pt1 (1997) for air flow and ISO 13347 for sound. © Pacific HVAC Engineering 2014 www.pacifichvac.com Tel. Australia 1300 733 833 NZ 0800 100 326 EC RCV Series - roof mounted centrifugal fans SPL dB referred to 10-12 W 500 1K 2K % Speed kW Amps RPS dB(A) @ 3m 63 125 250 4K 8K RCV190-VEE 100 0.08 0.75 53 52 61 61 66 67 66 68 62 64 RCV190-VEE 75 0.04 0.32 40 46 55 55 60 61 60 62 56 58 RCV190-VEE 50 0.01 0.09 27 37 46 46 51 52 51 53 47 49 RCV190-VEE 25 0.00 0.01 13 22 31 31 36 37 36 38 32 34 RCV280-VEE 100 0.50 2.20 45 63 73 72 78 81 79 74 72 78 RCV280-VEE 75 0.21 0.93 34 57 67 66 72 75 73 68 66 72 RCV280-VEE 50 0.06 0.28 23 48 58 57 63 66 64 59 57 63 RCV280-VEE 25 0.01 0.03 11 33 43 42 48 51 49 44 42 48 RCV315-VEE 100 0.50 2.20 45 63 73 72 78 81 79 74 72 78 RCV315-VEE 75 0.21 0.93 34 57 67 66 72 75 73 68 66 72 RCV315-VEE 50 0.06 0.28 23 48 58 57 63 66 64 59 57 63 RCV315-VEE 25 0.01 0.03 11 33 43 42 48 51 49 44 42 48 RCV355-VEE 75 0.21 0.93 23 51 65 70 70 70 64 67 57 52 RCV355-VEE 50 0.06 0.28 15 43 56 61 61 61 55 58 48 43 RCV355-VEE 25 0.01 0.03 8 27 41 46 46 46 40 43 33 28 RCD355-VEE 100 0.50 2.20 31 58 71 76 76 76 70 73 63 58 RCV400-VEE 100 0.50 2.20 31 58 71 76 76 76 70 73 63 58 RCV400-VEE 75 0.21 0.93 23 51 65 70 70 70 64 67 57 52 RCV400-VEE 50 0.06 0.28 15 43 56 61 61 61 55 58 48 43 RCV400-VEE 25 0.01 0.03 8 27 41 46 46 46 40 43 33 28 RCV450-VEE 100 0.75 3.30 24 58 71 76 76 76 70 73 63 58 RCV450-VEE 75 0.32 1.39 18 51 65 70 70 70 64 67 57 52 RCV450-VEE 50 0.09 0.41 12 43 56 61 61 61 55 58 48 43 RCV450-VEE 25 0.01 0.05 6 27 41 46 46 46 40 43 33 28 RCV450-VDE 100 0.97 1.70 26 58 71 76 76 76 70 73 63 58 RCV450-VDE 75 0.41 0.72 19 51 65 70 70 70 64 67 57 52 RCV450-VDE 50 0.12 0.21 13 43 56 61 61 61 55 58 48 43 RCV450-VDE 25 0.02 0.03 6 27 41 46 46 46 40 43 33 28 RCV500-VDE 100 2.36 3.65 26 65 77 80 83 82 77 77 76 79 RCV500-VDE 75 1.00 1.54 19 58 71 74 77 76 71 71 70 73 RCV500-VDE 50 0.30 0.46 13 50 62 65 68 67 62 62 61 64 RCV500-VDE 25 0.04 0.06 6 35 47 50 53 52 47 47 46 49 RCV560-VDE 100 2.36 3.65 26 65 77 80 83 82 77 77 76 79 RCV560-VDE 75 1.00 1.54 19 58 71 74 77 76 71 71 70 73 RCV560-VDE 50 0.30 0.46 13 50 62 65 68 67 62 62 61 64 RCV560-VDE 25 0.04 0.06 6 35 47 50 53 52 47 47 46 49 Model VEE = single phase. VDE = three phase © Pacific HVAC Engineering 2014 www.pacifichvac.com Tel. Australia 1300 733 833 NZ 0800 100 326 EC RCV Series - roof mounted centrifugal fans RCV190-VEE RCV280-VEE 500 1400 450 1200 400 1000 300 Pressure (Pa) Pressure (Pa) 350 250 100% 200 150 800 600 100% 400 75% 75% 100 50% 50 50% 200 25% 25% 0 0 0 50 100 150 200 0 250 100 200 300 400 500 600 700 800 900 1000 Air Flow (L/s) Air Flow (L/s) RCV315-VEE RCV355-VEE 1400 800 1200 700 600 1000 Pressure (Pa) Pressure (Pa) 500 800 600 100% 400 100% 300 400 200 75% 75% 50% 200 100 25% 50% 25% 0 0 0 100 200 300 400 500 600 700 800 900 1000 0 250 500 Air Flow (L/s) 750 1000 1250 1500 Air Flow (L/s) RCV400-VEE RCV450-VEE 800 700 700 600 600 500 Pressure (Pa) Pressure (Pa) 500 400 100% 300 400 300 100% 200 200 75% 75% 50% 50% 100 100 25% 25% 0 0 0 250 500 750 1000 1250 1500 0 Air Flow (L/s) © Pacific HVAC Engineering 2014 250 500 750 1000 1250 1500 1750 2000 Air Flow (L/s) www.pacifichvac.com Tel. Australia 1300 733 833 NZ 0800 100 326 EC RCV Series - roof mounted centrifugal fans RCV500-VDE RCV450-VDE 1000 700 900 600 800 700 Pressure (Pa) Pressure (Pa) 500 400 300 100% 75% 600 500 400 100% 300 200 75% 200 50% 50% 100 100 25% 25% 0 0 0 500 1000 1500 2000 2500 0 500 1000 1500 2000 2500 3000 3500 4000 4500 Air Flow (L/s) Air Flow (L/s) RCV560-VDE 1000 900 800 Pressure (Pa) 700 600 100% 500 400 300 75% 200 50% 100 25% 0 0 500 1000 1500 2000 2500 3000 3500 4000 Air Flow (L/s) © Pacific HVAC Engineering 2014 www.pacifichvac.com Tel. Australia 1300 733 833 NZ 0800 100 326
© Copyright 2025 ExpyDoc