RDV11

This is a static time relay in hermetically sealed metal-can
package with one NOC terminal; designed to switch DC
electrical circuits with fixed time intervals from 0,05 to 7200
seconds; manufactured according to GOST 16120-86 and
ЯЛ4.544.003 ТУ; applied in control engineering and supervision
systems for special and general industrial purposes.
Environmental ratings: humidity conditions.
Ordering data: Time Relay RDV 11 ЯЛ4.544.003-01 ЯЛ4.544.003 ТУ
Technical Parameters
Package Type
Dimension ( with terminals), mm
LxWxH
Switching Current, A
Switching Voltage, V
Residual Voltage on the Unsealed Relay (at -60oC), V, not
more than
Leakage Current of an Unsealed
Relay (at 85oC),mA, not more
than
Operating Voltage, V
Consumption Current, mA, not
more than
Recovery Time, ms , not more
than
Delay Time, sec.
Time-to failure, h
Derating Operation
(T≤550C,I≤0,2A,U≤40B),
Temperature, ºC
Humidity, %
Pressure, Pa
Vibration Loads, Hz/g
Shock Resistance, g
Weight, g, not more than
relay RDV 11
155.15-2
30х20х5(13)
0,4
4,5 – 80
0,8 (1,5)
0,2 (1,5)
27 +−74
15
50
0,05;0,1;0,2;0,3;0,35;0,5;0,75;1;1,5;2;3;4;5;7;8;10;20;30;40;45;50;60;9
0;120;150;180;240;300;360;480;600;900;960;1200;1800;1920;2400;3
600;7200
25000
50000
From minus 60 to plus 85
98 at 35оС
1,03·102 ÷ 3·105
1 - 3000/20
500
12
Equipment Identification Code
1
Models
Model
Delay Time,
sec.
1
2
ЯЛ4.544.003
ЯЛ4.544.003 - 01
ЯЛ4.544.003 - 02
ЯЛ4.544.003 - 03
ЯЛ4.544.003 - 04
ЯЛ4.544.003 - 05
ЯЛ4.544.003 - 06
ЯЛ4.544.003 - 07
ЯЛ4.544.003 - 08
ЯЛ4.544.003 - 09
ЯЛ4.544.003 - 16
ЯЛ4.544.003 - 17
ЯЛ4.544.003 - 18
0,05
0,1
0,2
0,3
0,5
1
2
3
5
10
20
30
40
Model
Delay Time,
sec.
3
ЯЛ4.544.003 - 19
ЯЛ4.544.003 - 20
ЯЛ4.544.003 - 21
ЯЛ4.544.003 - 22
ЯЛ4.544.003 - 23
ЯЛ4.544.003 - 24
ЯЛ4.544.003 - 25
ЯЛ4.544.003 - 26
ЯЛ4.544.003 - 27
ЯЛ4.544.003 - 28
ЯЛ4.544.003 - 29
ЯЛ4.544.003 - 30
ЯЛ4.544.003 - 31
Delay Time,
sec.
Model
4
5
6
45
60
90
120
180
240
300
360
480
600
900
960
1200
ЯЛ4.544.003 - 32
ЯЛ4.544.003 - 33
ЯЛ4.544.003 - 34
ЯЛ4.544.003 - 35
ЯЛ4.544.003 - 36
ЯЛ4.544.003 - 37
ЯЛ4.544.003 - 38
ЯЛ4.544.003 - 39
ЯЛ4.544.003 - 40
ЯЛ4.544.003 - 41
ЯЛ4.544.003 - 42
ЯЛ4.544.003 - 43
ЯЛ4.544.003 - 44
1800
1920
2400
3600
7200
150
0,35
1,5
4,0
7,0
8,0
0.75
50
Technical Specifications
Operating Voltage, V
Consumption Current, mA, not more than
Residual Voltage at “On”-position, V, not more than
Leakage Current of an Output Circuit at “Off”-position, mA :
- at 25 С°
- at 85 С°
Switching Voltage, V
Maximal Switching Current, A
Operation Time Tolerance, %:
from 15 to 35 С°
from -60 to +15°С, from 35 to 85°С
Weight, g not more than
27 (+7− 4)
15
1,5
0,2
1,5
4,5−80
0,4
±3
±10
12
Electric Strength and Insulation Resistance
Test Conditions
Test Voltage, V
Insulation Resistance,
mOhm, not less
Normal Ambient Temperature
Maximal Operating Temperature
Low Air Pressure
High Humidity, Silver Thaw and Dew, Salt Fog, Mold & Fungi,
Static Dust
180
110
200
20
-
110
10
relay RDV 11
2
Equipment Identification Code
Reliability
Minimal operating time during life limit is not less than 25000 hours; at derating operation
conditions not less than 50000 hours.
Minimal storage time in a heated storehouse , as well as being mounted in insulated
equipment or in protected SPTA (spare parts, tools and accessories) not less than 15 years.
Minimal operating life limit is not less than 15 years.
Reference value of 95% gamma-percentile life is not less than 40000 hours, in derating
operation conditions not less than 80000 hours.
Mounting View and Mounting
Dimensions
Terminals Function and Position
1 – regulator terminal
2 – control
3-6,12,13 – blank terminals
7 –common leg
8 –common leg in switching
circuit
9 –calibration
10 –load
11 –protection
14 –power supply (operating
voltage)
15 –package
Connection Diagram
Operating Voltage Supply via Electromechanical Contacts
Control of TTL Micro Output
(5 ± 0 ,5 ) В
300
01
D
02
КТ
14
02
D
В ы х.
07
07
08
О бщ ий
Active Load Connection
Inductive Load Connection
Uk
КТ
КТ
L
КТ
R
11
10
11
08
relay RDV 11
Uk
-Uk
R
08
-U k
Equipment Identification Code
3
Operating Conditions
Operating Temperature Range, °С
Sinusoidal Vibration :
frequency range, Hz
acceleration amplitude, m/sec² (g)
Single Mechanical Shock :
shock acceleration peak value, m/sec2 (g)
duration of shock acceleration, ms
Multiple Mechanical Shocks :
shock acceleration peak value, m/sec² (g)
duration of shock acceleration, ms
Linear Acceleration, m/sec² (g)
Acoustic Noise :
frequency range, Hz
sound pressure level, dB
Low Air Pressure, Pa, (mm of Mercury)
High Air Pressure, kgf/сm²
High Relative Humidity at 35°С, %
Static Dust, Salt Fog, Mold & Fungi, Silver Thaw and Dew.
Russia 173021 Velikiy Novgorod,
Nekhinskaya-street, 55
Fax +7 8162 616 446
E-mail: [email protected]
www.relay-start.ru
4
From minus 60 to plus 85
1 - 3000
200 (20)
5000 (500)
0,1 - 2,0
750 (75)
1-5
1500 (150)
50 - 10000
130
1,3.10¯4 (10¯6)
3
98
According to GOST 16120-86
relay RDV 11