Technical data sheet · DIOLINE PLC COS/COM Subject to technical modification 746032 Identification Product version Datasheet version Use/Area of application Description General Controller Software Type Part-No. DL-PLC-COS-COM-LUE 746032 01 Flexible powerful compact control unit for use in rail vehicles. Freely programmable in a comfortable IEC 61131-3 development environment. Flexible field-bus configuration with CANopen Master and Slave. L-Bus interface for connection of local I/O modules. CPU ARM926 200 MHz 32 Bit 4 MB flash program memory 4 kB FRAM memory for retain data 32 MB SD RAM 2 MB flash memory for diagnostic SD memory slot real time clock watchdog for system monitoring start-up time: approx. 15 s realtime operating system rcX Soft-PLC KW Software ProConOS® Programming languages as per IEC 61131-3: FBD, LD, ST, IL, SFC flexible fieldbus configuration visualization per OPC Bus interface Bus system Module type Connection type, incoming bus Connection type, continuing bus Bus system Fieldbuses: FB1: CANopen Slave X2: SUB-D socket connector, 9-pin, M3 thread X3: SUB-D plug connector, 9-pin, M3 thread FB2: CANopen 02.09.2014 – Subject to technical modification Part-No. 746032 page 1 of 3 Technical data sheet · DIOLINE PLC COS/COM Module type Connection type, incoming bus Connection type, continuing bus Configuration Bus system Module type Bus system Module type Connection Bus system Module type Connection Electronic module supply Voltage range, incl. ripple Ripple Rated current (at UN) Current consumption via local bus External fuse Connection Diagnostics Diagnosis indications Master X4: SUB-D socket connector, 9-pin, M3 thread X5: SUB-D plug connector, 9-pin, M3 thread The field buses are configuerd by software Local bus: L-Bus Interface for local I/O modules Master max. number of connectable slaves: 10 Ethernet: TCP/IP or OPC generic X6: 4-pin M12 connector D-coded programming and debugging interface Diagnostic: Serial Interface RS232 generic X7: SUB-D plug connector, 9-pin, M3 thread DC 16.8-30 V max. 10 % 200 mA + current consumption of connected L-Bus modules 2 A fusible link, in case of internal short circuit 1.25 A fusible link, in case of short-circuit of L-Bus interface max. 1 A B2 to B16 X1: Terminal, 5-pin Spring terminal: 0.14 – 2.5 mm2 , AWG 22 – 12 Stripping Length: 11 mm Screwdriver: 3,5 × 0,6 mm device status (PLC) LED yellow function programmable (APP) LED red/green CANopen Slave (FB1ST) LED green CANopen Slave (FB1ERR) LED red CANopen Master Status (FB2ST) LED green CANopen Master Error (FB2ERR)) LED red L-Bus Status (LBUS) LED red/green logic power supply (UL) LED green Ethernet Link (LNK) LED green Ethernet Activity (ACT) LED yellow push-button (J1USER) function programmable push-button (J2RESET) für warm start Electrical isolation Isolating voltage Technical data Dimensions (w × h × d) Weight (kg/piece) Protection class AC 500 V Ethernet and elektronics AC 500 V CAN and elektronics 123.0 × 141.5 × 64.1 mm 0.550 kg/piece IP 20 02.09.2014 – Subject to technical modification Part-No. 746032 page 2 of 3 Technical data sheet · DIOLINE PLC COS/COM Field installation Installation postition Operating temperature Storage temperature range min/max DIN rail mounting As desired Installation space: top: 5 mm (for assembly) bottom: 5 mm (for assembly) side: 0 mm -40 °C to +70 °C -40 °C to +85 °C PE connection Connection tab X0: 6.3 mm × 0.8 mm Miscellaneous Use Accessories compact vehicle control unit individual driver and software development possible SUB-D refitting set M3 in UNC4/40 Article number 746840 Not contained in scope of delivery Screwless terminal, power supply Article number 745861 Contained in scope of delivery Dimensions 02.09.2014 – Subject to technical modification Part-No. 746032 page 3 of 3
© Copyright 2025 ExpyDoc