Dimension Sheet Plate Heat Exchanger Customer: Order No.: Serial No.: Flow Diagram No.: GEA Ecoflex UK Ltd. 2094643171 Customer item: 800 lph Ice Cream Mix Pasteuriser 111/12039 S111/12039 ZM111/12039 Drawing No.: Type: NT50M CDL-S-16 n: k: l: 1255 mm 1213 mm 1200 mm s1: 25,00 mm s2: 25,00 mm Dimensions of drawing in [mm] a-max frame: a-max actual: 554 mm 324 mm Item No.: 10 0050-337-1-Layout1.tif empty weight: max. total weight: 287 kg 314 kg 2 Connections on frame plates Pos 3F 4F 2L 3L 4L Size DN50 DN50 DN50 DN50 DN50 Type Threaded connection RJT 2” Threaded connection RJT 2 Threaded connection RJT 2” Threaded connection RJT 2” Threaded connection RJT 2” Media Ice Mix Hot Water Chilled Water Chilled Water Ice Mix In x x - Out x x x m 70 mm 70 mm 70 mm 70 mm 70 mm Media Ice Mix Hot Water Ice Mix Ice Mix Ice Mix In x x x Out x x - m 118 mm 117 mm 117 mm 118 mm 118 mm Threaded connection RJT 2” AISI316L 3F;4F;2L;3L;4L Connections on intermediate plates Pos 1.3LH 1.4LV 1.3FV 1.4FH 2.2LH Size DN40 DN40 DN40 DN40 DN40 Type Threaded connection RJT1 ½” Threaded connection RJT 1 ½” Threaded connection RJT 1 ½” Threaded connection RJT 1 ½” Threaded connection RJT 1 ½” Corner types on intermediate plates Double corner: Amount: 2 Single corner: Amount: 1 Technical Revisions reserved. Layer thickness in case of painted frames acc. DIN EN ISO 12944-5, frame plate surface quality acc. DIN EN 10029. The design details are valid for phe manufactured by GEA Ecoflex GmbH/Sarstedt.