220 REFERENCES 1. Alam M.J. and Santhakumar A.R. (1996), ‘Reliability Analysis and Full-Scale Testing of Transmission Tower’, Journal of Structural Engineering, Vol. 122, No. 3, pp. 338-344. 2. Al-Bermani F. and Kitipornchai S. (2003), ‘Numerical Simulation of Structural Behaviour of Transmission Towers’, Journal of Thin walled Structures, Vol. 41, Nos. 2-3, pp. 167-177. 3. Al-Bermani F., Kitipornchai S. and Chan R.W.K. (2009), ‘Failure Analysis of Transmission Towers’, Journal of Engineering Failure Analysis, Vol. 16, pp. 1922-1928. 4. Al-Bermani F., Mahendran M. and Kitipornchai S. (2004), ‘Upgrading of Transmission Towers Using a Diaphragm Bracing System’, Journal of Engineering Structures, Vol. 26, pp. 735-744. 5. Al-Bermani F.G.A. and Kitipornchai S. (1993), ‘Nonlinear Finite Element Analysis of Latticed Transmission Towers’, Engineering Structures, Vol. 15, No. 4, pp. 259-269. 6. Al-Bermani F.G.A. and Kitipornchai S. (1992), ‘Nonlinear Analysis of Transmission Towers’, Engineering Structures, Vol. 14, No. 3, pp. 139-150. 7. Ali Davaran (2001), ‘Effective Length Factor for Discontinuous X-Bracing Systems’, Journal of Engineering Mechanics, Vol. 127, No. 2, pp. 106-112. 8. Ali Davaran and Nader Hoveidae (2009), ‘Effect of Mid-Connection Detail on the Behaviour of X-Bracing Systems’, Journal of Constructional Steel Research, Vol. 65, pp. 985-990. 9. Anjam. R (1991), ‘Galloping and Broken Conductor Analysis of Transmission Lines’, Ph.D thesis, Iowa State University, Ames, Iowa. 221 10. Byoung-Wook Moon, Ji-Hun Park, Sung-Kyung Lee, Jinoo Kim, Taejin Kim and Kyung-Won Min (2009), ‘Performance Evaluation of a Transmission Tower by Substructure Test’, Journal of Constructional Steel Research, Vol. 65, pp. 1-11. 11. Cannon D.D. and Nickerson R. (1993) ‘Results of TLMRC Research on X-Bracing Strength in Lattice Transmission Towers’, IEEE Transactions on Power Delivery, Vol. 8, No. 1, pp. 285-292. 12. “Code of practice for General Construction in Steel” (2007). IS: 800, Bureau of Indian Standards, New Delhi, India. 13. “Code of practice for Use of Structural Steel in Over Head Transmission Line Towers - Permissible stresses.” (1992). IS: 802 (Part 1 / Sec 2), Bureau of Indian Standards, New Delhi, India. 14. “Code of practice for Use of Structural Steel in Over Head Transmission Line Towers- Testing.” (1978). IS: 802, (Part III) Bureau of Indian Standards, New Delhi, India. 15. Da Silva J.G.S, Da Vellasco.P.C.G.S, De Andrade S.A.L., DE Oliveira.M.I.R. (2005), ‘Structural Assessment of Current Steel Design Models for Transmission and Telecommunication Towers’, Journal of Constructional Steel Research, Vol. 61, pp. 1108- 1134 16. “Design of Latticed Steel Transmission Structures.” (2000). American Standard ASCE 10- 97, Reston, Virginia. 17. Elgaaly M., Davids W. and Dagher H. (1992), ‘Non Slender Single Angle Struts’, Engineering Journal, American Institute of Steel Construction, Second Quarter, pp. 49-58. 18. Faisal Abdullah and Al-Mashary (1999), ‘Nonlinear Analysis of Transmission Towers’, J. King Saud University, Vol. 11, Eng. Sci., Vol. 11, pp. 19-32. 19. Faisal Al-Mashary, Abdulrahim Arafah, Ghulam Husain Siddiqi and Yousef Al-Salloum (1992), ‘The Report on Investigation of Failure of Six Transmission Towers’, Riyadh: Saudi Consolidated Electricity Company. 20. Fernandez J., Pernia A., Martinez-de-Pison F.J., Lostado R. (2010), ‘Prediction Models for Calculating Bolted Connections using Data Mining Techniques and the Finite Element Method’, Journal of Engineering Structures, 32, pp. 3018-3027. 222 21. Fred Segal, Robert Levy and Avigdor Rutenberg (1994) ‘Design of Imperfect Cross–Bracings’, Journal of Engineering Mechanics, Vol. 120, No. 5, pp. 1057-1074. 22. Hemant Patil, Gaurang Doshi, Prasad Rao N., Deepak Lakhpati and Venkat Subramanian (2010), ‘Failure Analysis of Transmission Line Towers: A Case Study’, The IUP Journal of Structural Engineering, Vol. 3, No. 1, pp. 20-27. 23. Hong-Nan Li, Wen-Long Shi, Guo-Xin Wang and Lian-Guang Jia (2005), ‘Simplified Models and Experimental Verification for Coupled Transmission Tower Line System to Seismic Excitations’, Journal of Sound and Vibration, Vol. 286, pp. 569-585. 24. Hwan-Seon Nah, Hyeon-Ju Lee and Kang-Seok Kim (2009) ‘Evaluation of Slip Coefficient of Slip Critical Joints with High Strength Bolts’, Journal of Structural Engineering and Mechanics, Vol. 32, No. 4, pp. 477-488. 25. Issa R.R.A. and Richard Avent R. (1995), ‘Discrete-Field Stability Analysis of X-Braced Lattices’, Journal of Structural Engineering, Vol. 121, No. 8, pp. 1213-1220. 26. Jared J. Perez, Wendelin H. Mueller III, and Leon Kempner. Jr. (2009), ‘Strength of Steel Angles Subjected to Short Duration Axial Loads’ conference proceedings on ‘Electrical Transmission and Substation Structures’, Technology for the Next Generation, pp. 473-478. 27. Jiho Moon, Ki-Yong Yoon, Tong-Seok Han and Hak-Eun Lee (2008), ‘Out of Plane Buckling and Design of X-Bracing Systems with Discontinuous Diagonals’, Journal of Constructional Steel Research, Vol. 64, pp. 285-294. 28. Ju S.H., Fan C.Y. and Wu G.H. (2004), ‘Three Dimensional Finite Elements of Steel Bolted Connections’, Engineering Structures, Vol. 26, pp. 403-413. 29. Kemp A.R. and Behncke R.H. (1998), ‘Behaviour of Cross-Bracing in Latticed Towers’, Journal of Structural Engineering, Vol. 124, No. 4, pp. 360-367. 30. Kitipornchai S., Peyrot A.H. and Al-Bermani F.G.A. (1994), ‘Effect of Bolt Slippage on Ultimate Behaviour of Lattice Structures’, Journal of Structural Engineering, Vol. 120, No. 8, pp. 2281-2287. 223 31. Knight G.M.S. and Santhakumar A.R. (1993), ‘Joint Effects on Behaviour of Transmission Towers’, Journal of Structural Engineering, Vol. 119, No. 3, pp. 698-712. 32. “Lattice Towers and Masts: Part 3 Code of Practice for Strength Assessment of Members of Lattice Towers and Masts.” (1999). British Standard BS: 8100 - 3:1999, British Standards Institution, London. 33. Li Li (1990), ‘Dynamic Loads on Pole Transmission Line Structures from Galloping Conductors’, Ph.D thesis, Iowa State University, Ames, Iowa. 34. Loading tests on overhead line structures, IEC 60 652, 2002, Geneva, Switzerland. 35. McClure G. and Lapointe M. (2003), ‘Modeling the Structural Dynamic Response of Overhead Transmission Lines’, Computers and Structures, Vol. 81, pp. 825-834. 36. Menezes R.C.R and Da Silva B.G.F., (2000), ‘On the Variability of Mechanical Properties for Transmission Line Steel Towers’, Authors Study Committee SC 22 WG (TF) WG 22.08 Journal of ‘ELECTRA’ ELT_189_3 . pp 57- 71 37. Mohan Gupta and Gupta L.M. (2004), ‘Evaluation of Stress Distribution in Bolted Steel Angles under Tension’, Electronic Journal of Structural Engineering, Vol. 4, pp. 17-27. 38. Murtagh.P.J, Basu.B, and Broderick.B.M. (2004), ‘Simple Models for Natural Frequencies and Mode Shapes of Towers Supporting Utilities’, Journal of Computers and Structures, 82, pp. 1745–1750. 39. Natarajan K. and Santhakumar A.R. (1995), ‘Reliability - Based Optimization of Transmission Line Towers’, Journal of Computers and Structures, Vol. 55, pp. 387-403. 40. NE-NASTRAN, Version 8.1, 2001, Noran Engineering inc, Los Alamitos, United States of America. 41. Phill-Seung Lee and Ghyslaine McClure (2007), ‘Elastoplastic Large Deformation Analysis of a Lattice Steel Tower Structure and Comparison with Full-Scale Tests’, Journal of Constructional Steel Research, Vol. 63, pp. 709 - 717. 224 42. Picard A. and Beaulieu D. (1987) ‘Design of Diagonal Cross cross bracings Part 1: Theoretical study’, Engineering Journal / American Institute of Steel Construction’, Third Quarter, pp. 122-126. 43. Prasad Rao N., Mohan S.J. and Lakshmanan N. (2004), ‘A Semi Empirical Approach for Estimating Displacements and Fundamental Frequency of Transmission Line Towers’, Journal of Structural Stability and Dynamics, Vol. 4, No. 2, pp. 181-195. 44. Rao N.P. and Kalyanaraman V. (2001), ‘Non Linear Behaviour of Lattice Panel of Angle Tower’, Journal of Constructional Steel Research, Vol. 57, pp. 1337-1357. 45. Rao N.P., Mohan S.J. and Lakshmanan N. (2005), ‘A study on Failure of Cross Arms in Transmission Line Towers during Prototype Testing’, Journal of Structural Stability and Dynamics, Vol. 5, No. 3, pp. 1337-1357. 46. Reid J.D. and Hiser N.R. (2005), ‘Detailed Modeling of Bolted Joints with Slippage’, Journal of Finite Elements in Analysis and Design, Vol. 41, pp. 547-562. 47. Ronaldo C. Battista, Rosangela S. Rodrigues, and Michele S. Pfeil (2003), ‘Dynamic Behaviour and Stability of Transmission Line Towers Under Wind Forces’, Journal of Wind Engineering and Industrial Aerodynamics, 91, pp. 1051-1067. 48. Sanjeev Gupta, Wipf T.J., Fanous F., Baenziger M. and Hahm Y.H. (1994), ‘Structural Failure Analysis of 345 kV Transmission Line’, IEEE Transactions on Power Delivery, Vol. 9, No. 2, pp. 894-903. 49. Stoman S.H. (1988) ‘Stability Criteria for X -bracing Systems’, Journal of Engineering Mechanics, Vol. 114, No. 8, pp. 1426-1434. 50. Stoman S.H. (1989) ‘Effective Length Spectra for Cross Bracings’, Journal of Structural Engineering, Vol. 115, No. 12, pp. 3112-3122. 51. Ungkurapinan N., Chandrakeerthy S.R. De S., Rajapakse R.K.N.D. and Yue S.B. (2003), ‘Joint Slip in Steel Electric Transmission Towers’, Engineering Structures, Vol. 25, pp. 779-788. 52. Timoshenko and Gere (1985), ‘Theory of Elastic Stability’, International student edition, Second edition, McGraw-Hill Book Company, Inc., Singapore. 225 53. Wang D.Q. and Boresi A.P. (1992) ‘Theoretical Study of Stability Criteria for X –Bracing Systems’, Journal of Engineering Mechanics, Vol. 118, No. 7, pp. 1357-1364. 54. Wipf. T, Baenziger. M, Fanous. F, Gupta. S and Anjam. R (1991), ‘Ice Storm Damage Assessment of the Lehigh- Sycamore 345kV Transmission Line’, final report submitted to Iowa Power Company, Ames, Iowa. 55. Xiaohong Zhang (2009), ‘Dynamic post-elastic response of transmission towers’, Ph.D thesis, Department of Civil Engineering and Applied Mechanics, McGill University. Canada. 56. Zinnia Nair, Aparna K.M., Khandagale R.S. and Gopalan T.V. (2005), ‘Failure of 220 kV Double Circuit Transmission Line Tower Due to Lightning’, Journal of Performance of Constructed Facilities, Vol. 19, pp. 132-137.
© Copyright 2024 ExpyDoc