Zelio™ Plug-In Relays

Zelio Plug-In Relays
™
RXM miniature relays
Data Bulletin
2014
Zelio™ Plug-In Relays
Introduction
RXM miniature relays
Introduction of the product range
7
The RXM miniature relay range includes:
1 12 A relays with 2 C/O contacts, 10 A relays with 3 C/O contacts, 6 A relays with
4 C/O contacts and 3 A “low level” relays with 4 C/O contacts. All these relays
have the same dimensions.
2 Sockets with mixed or separate contact terminals.
3 Protection modules (diode, RC circuit or varistor).
4 Metal hold-down clip for all sockets.
5 Plastic hold-down ejector clip for all sockets.
6 2-pole bus jumper that can be used on sockets with separate contact terminals
in order to simplify wiring when creating a jumper between the coil terminals.
7 Clip-in ID tags for all the sockets except RXZE2M114.
2
1
4
or
5
6
Relay description
3
8
1
2
3
4
5
76
9
9
10
6
1 Spring return push-to-test button for checking contact operation (green: DC coil,
red: AC coil).
2 Mechanical “relay status” indicator.
3 Optional removable lock-down door enables continuous engagement of the
contacts for test or maintenance purposes. During normal operation, this
lock-down door must always be in the closed position.
4 Bipolar LED indicating the relay status.
5 Removable ID tag for relay identification.
6 Four notches for DIN rail mounting adapter or panel mounting adapter with
mounting lugs.
7 Eight, eleven or fourteen quick-connect pins.
8 Finger grips for easy removal of the relay from a socket.
9 Mounting adapter for direct mounting of the relay on a panel.
10Mounting adapter for direct mounting of the relay on a DIN rail.
Socket description
1
Sockets with mixed contact terminals (1)
1 Connection by screw clamp terminals or box lug connector.
2 Fourteen female contacts for the relay pins.
3 Location for protection modules.
4 Locking components for plastic and metal hold-down clips.
5 Locating slot for mounting on DIN rail.
6 Two or four mounting holes for panel mounting.
Outputs
2
4
3
Inputs
5
5
Relay coil
terminals
Sockets with separate contact terminals (2)
1 Connection by screw connector.
2 Connection by push-in spring clamp terminals. No tool is required to insert the
cable.
3 Eight, eleven or fourteen female contacts for the relay pins.
4 Location for protection modules.
5 Locking components for plastic and metal hold-down clips.
6 Locating slot for mounting on DIN rail.
7 Two mounting holes for panel mounting.
8 Location for bus jumpers (see “Mounting on Sockets” section on
www.schneider-electric.com).
9 Location for clip-in ID tag.
7
1
2
Inputs
Outputs
3
5
4
6 8
6
Introduction:
page 2
Relay coil terminals
6
Specifications
page 4
9
(1) The inputs are mixed with the relay coil terminals, with the outputs being located on the
opposite side of the socket.
(2)The inputs and outputs are separated from the relay coil terminals.
References:
page 6
Dimensions:
page 9
Wiring:
page 12
3
Zelio™ Plug-In Relays
Specifications
RXM miniature relays
General specifications
Conforming to standards
Product certifications
IEC/EN 61810-1, UL 508, CSA C22-2 n° 14
cULus File E164862 CCN NLDX, NLDX7; cURus File E164862 CCN NLDX2, NLDX8; CSA; CE; Lloyds
Register; GOST; RoHS compliant
°C (F) - 40… + 85 (-40... +185)
°C (F) - 40… + 55 (-40... +131)
3 gn (35...150 Hz), +/- 1 mm (10...35 Hz) with and without retention clip
5 gn (35...150 Hz), +/- 1 mm (10...35 Hz) with and without retention clip
Ambient air temperature Storage
around the device
Operation
Vibration resistance
In operation
conforming to
Not operating
IEC/EN 60068-2-6
Degree of protection
Conforming to
IEC/EN 60529
Shock resistance
In operation
conforming to
Not operating
IEC/EN 60068-2-27
Protection category
Mounting position
IP 40
10 gn (11 ms) with retention clip
30 gn (11 ms) with retention clip
RT I
Any
Insulation specifications
Rated insulation voltage (Ui)
Rated impulse withstand voltage (Uimp)
Dielectric strength
Between coil/contact
(rms voltage)
Between poles
Between contacts
Contact specifications
V
kV
Vac
Vac
Vac
250 (IEC), 300 (UL, CSA)
4 (1.2/50 ms) for RXM 2ppppp and RXM 3ppppp; 2.5 (1.2/50 ms) for RXM 4ppppp
2000
2000
1300
Relay type
Number and type of contacts
Contact materials
RXM 2ABppp
2 C/O
Ag alloy with Au flash
RXM 3ABppp
3 C/O
RXM 4ABppp
4 C/O
Conventional thermal
current (Ith)
Rated operational current
in utilization categories
AC-1 and DC-1
Switching current
Switching voltage
12
10
6
RXM 4GBppp
4 C/O low level
Ag with Au flash bifurcated
3
12
6
10
5
6
3
2
1
For ambient
A
temperature y 55 °C
Conforming to N.O.
IEC
N.C.
Minimum
Maximum
Minimum
Nominal load
(conforming to IEC,
resistive, 100K cycles)
Rated operational
current (conforming
to UL)
Resistive
Motor
Pilot Duty
Switching capacity
Maximum
AC
DC
Minimum
Maximum operating rate No-load
In operating cycles per hour Under load
Utilization coefficient
Mechanical durability
Cycles
mA
V
V
A
10
3
250 Vac / 28 Vdc (IEC); 300 Vac / 30 Vdc (UL)
17 Vdc
5 Vdc
12 at 250 Vac (100K cycles) 10 at 250 Vac (100K cycles) 6 at 250 Vac (100K cycles) 3 at 250 Vac (100K cycles)(1)
A
12 at 28 Vdc (100K cycles) 10 at 28 Vdc (100K cycles) 6 at 28 Vdc (100K cycles) 3 at 28 Vdc (100K cycles)(1)
A
A
A
hp
hp
12 at 277 Vac (100K cycles)
12 at 120 Vac (200K cycles)
12 at 30 Vdc (100K cycles)
1/2 at 120 Vac (6K cycles)
1 at 277 Vac (6K cycles)
B300
VA 3000
W
336
mW 170
18 000
1200
20 %
10 000 000
10 at 277 Vac (100K cycles)
10 at 120 Vac (200K cycles)
10 at 30 Vdc (100K cycles)
1/3 at 120 Vac (6K cycles)
1 at 277 Vac (6K cycles)
B300
6 at 277 Vac (200K cycles)
8 at 120 Vac (200K cycles)
8 at 30 Vdc (200K cycles)
1/3 at 120 Vac (6K cycles)
1/2 at 277 Vac (6K cycles)
B300
2500
280
1500
168
3 at 277 Vac (100K cycles)(1)
3 at 120 Vdc (100K cycles)(1)
3 at 30 Vdc (100K cycles)(1)
1/16 at 120 Vac (6K cycles)(1)
2.8 A FLA at 120 Vac
5 A make, 0.5 A break, 3A
continuous at 120 Vac(1)
750
84
15
(1)When mounted horizontally
Reduction coefficient for inductive load (AC)
(depending on power factor cos j)
107
106
D
C
105
0
A
Introduction:
page 2
4
0,6
0,5
10
6
3
0,4
1
A
B
D
1
2
Switching capacity (kVA)
A RXM 2ABppp
1
0,8
Maximum switching capacity on resistive load
(DC)
Current c
Reduction coefficient (A)
Durability (Number of operating cycles)
Electrical durability of contacts
Resistive load (AC)
0,3
3
B RXM 3ABppp
C RXM 4ABppp
Specifications
page 4
0,1
1
0,6
0,4
0,2
0
B
C
28 50
100
150
200
250
Voltage (Vdc)
D RXM 4GBppp Durability (inductive load) = durability (resistive load) x reduction coefficient.
References:
page 6
Dimensions:
page 9
Wiring:
page 12
Zelio™ Plug-In Relays
Specifications (continued)
RXM miniature relays
Coil specifications
Average consumption
Drop-out voltage threshold
AC
VA
0.9–1.2
DC
W
0.8–1.1
AC
u 0.15 Uc
DC
Operating time
(response time)
u 0.1 Uc
Between coil energization
and making of the
On-delay contact
AC
ms
20 (max.)
DC
ms
20 (max.)
Between coil de-energization
and making of the
Off-delay contact
AC
ms
20 (max.)
DC
ms
20 (max.)
V
12
24
48
110
120
125
220
230
240
JD
BD
ED
FD
–
GD
MD
–
–
Control circuit voltage Uc
Relay control voltage codes
DC supply
Average resistance at 20 °C ± 10%
W
160
650
2560
13 440
–
17 360
48 400
–
–
Operating voltage limits
Min.
Vac
9.6
19.2
38.4
88
–
100
176
–
–
Max.
Vac
13.2
26.4
52.8
121
–
138
242
–
–
–
B7
E7
F7
–
–
P7
U7
Relay control voltage codes
AC supply
Average resistance at 20 °C ± 15%
W
–
177
708
–
3630
–
–
16 270
17 720
Operating voltage limits
Min.
Vdc
–
19.2
38.4
–
96
–
–
184
192
Max.
Vdc
–
26.4
52.8
–
132
–
–
253
264
Socket specifications
Socket type
RXZE2S108M RXZE2S111M RXZE2S114M RXZE2S114S
RXZE2M114M
RXZE2M114
Relay types used
RXM2ppppp RXM3ppppp RXM4ppppp RXM2ppppp
RXM4ppppp
RXM2ppppp (1)
RXM4ppppp
RXM2ppppp (1)
RXM4ppppp
Contact terminal arrangement
Wire connection method
Separate
Box lug connectors
Mixed
Spring clamp
Box lug connectors Screw clamp
terminals
terminals
cURus File E172326 CCN SWIV2, SWIV8; CSA; CE; GOST; Lloyds; RoHS compliant
IEC 61984, UL 508, CSA 22.2 No. 14
Product certifications
Conforming to standards
Electrical specifications
Conventional thermal current (Ith)
A
12
Maximum operating voltage
Vac
250 (IEC)
Between adjacent output contacts
Between input and output contacts
Vrms
Vrms
Vrms
2500
2500
2500
Insulation specifications
Between contacts and DIN rail
10
12 (2-Pole),
6 (4-Pole)
10
General specifications
Ambient air temperature Operation
°C (°F) - 40…+ 40 (- 40…+ 104)
around the device
Storage
°C (°F) - 40…+ 85 (- 40…+ 185)
Degree of protection
Conforming to IEC/EN
IP 20
60529
Connection
Solid wire 1 conductor
0.5…2.5 mm2 - AWG 20…AWG 14
mm
without
in.
cable end 2 conductors
0.5…1.5 mm2 - AWG 20…AWG 16
Flexible 1 conductor
0.25…2.5 mm2 - AWG 22…AWG 14
wire with
cable end 2 conductors
0.25…1 mm2 - AWG 22…AWG 17
Mounting on DIN rail
Terminal referencing
Bus jumper (Ith: 5 A)
Compatibility with the plastic hold-down
ejector clip
Compatibility with the metal hold-down clip
Protection module compatibility
Clip-in ID tag compatibility
Wire connection method
Nm
0.35 ~ 0.43
0.5…1.5 mm2
0.25…2.5 mm2
0.25…1 mm2
AWG 20…AWG 16 AWG 22…AWG 14 AWG 22…AWG 17
0.5…1.5 mm2
0.25…1 mm2 - AWG 22…AWG 17
AWG 20…AWG 16
1 / M3 screw
On 35 mm DIN rail / on panel
By plastic clip
mm
in.
2.5
0.098
Maximum tightening torque / Screw size
Mounting
0.5…1.5 mm2
0.5…2.5 mm2
0.5… 1.5 mm2
9 ~ 11 16 AWG 20…AWG 14 AWG 20…AWG 16
AWG 20…AWG
IEC, NEMA
Yes
Yes
Yes
All RXM040W, RXM041pp, RXM021pp
Yes (see page 6 for more information)
(1)
Screw connector
By metal
compression
spring
By plastic clip
No
Spring clamp
terminals
(2)
Screw connector
No
Screw clamp
terminals
(1)When mounting relay RXM2ppppp on socket RXZE2Mpppp, the thermal current must not exceed 10A.
5
Zelio™ Plug-In Relays
References
RXM miniature relays
Miniature relays with lockable test button only (sold in lots of 10)
Control
circuit
voltage
Number and type of contacts - Thermal current (Ith)
2 C/O - 12 A
Unit
reference
V
12 Vdc
RXM4AB1BD
RXM4AB1F7
3 C/O - 10 A
Weight
Unit
reference
kg (lb)
RXM2AB1JD
0.037 (0.082)
4 C/O - 6 A
Weight
Unit
reference
kg (lb)
RXM3AB1JD
0.037 (0.082)
Weight
kg (lb)
RXM4AB1JD
0.037 (0.082)
24 Vdc
RXM2AB1BD 0.037 (0.082)
RXM3AB1BD 0.037 (0.082)
RXM4AB1BD 0.037 (0.082)
48 Vdc
RXM2AB1ED 0.037 (0.082)
RXM3AB1ED 0.037 (0.082)
RXM4AB1ED 0.037 (0.082)
110 Vdc
RXM2AB1FD 0.037 (0.082)
RXM3AB1FD 0.037 (0.082)
RXM4AB1FD 0.037 (0.082)
220 Vdc
–
–
RXM4AB1MD 0.037 (0.082)
–
–
24 Vac
RXM2AB1B7
0.037 (0.082)
RXM3AB1B7
0.037 (0.082)
RXM4AB1B7
0.037 (0.082)
48 Vac
RXM2AB1E7
0.037 (0.082)
RXM3AB1E7
0.037 (0.082)
RXM4AB1E7
0.037 (0.082)
120 Vac
RXM2AB1F7
0.037 (0.082)
RXM3AB1F7
0.037 (0.082)
RXM4AB1F7
0.037 (0.082)
230 Vac
RXM2AB1P7
0.037 (0.082)
RXM3AB1P7
0.037 (0.082)
RXM4AB1P7
0.037 (0.082)
240 Vac
–
–
RXM4AB1U7
0.037 (0.082)
RXM4AB2JD
0.037 (0.082)
–
–
Miniature relays with LED and lockable test button (sold in lots of 10)
RXM4AB2BD
12 Vdc
RXM2AB2JD
24 Vdc
RXM2AB2BD 0.037 (0.082)
0.037 (0.082)
RXM3AB2JD
0.037 (0.082)
RXM3AB2BD 0.037 (0.082)
RXM4AB2BD 0.037 (0.082)
48 Vdc
RXM2AB2ED 0.037 (0.082)
RXM3AB2ED 0.037 (0.082)
RXM4AB2ED 0.037 (0.082)
110 Vdc
RXM2AB2FD 0.037 (0.082)
RXM3AB2FD 0.037 (0.082)
RXM4AB2FD 0.037 (0.082)
125 Vdc
–
–
RXM4AB2GD 0.037 (0.082)
–
–
24 Vac
RXM2AB2B7
0.037 (0.082)
RXM3AB2B7
0.037 (0.082)
RXM4AB2B7
0.037 (0.082)
48 Vac
RXM2AB2E7
0.037 (0.082)
RXM3AB2E7
0.037 (0.082)
RXM4AB2E7
0.037 (0.082)
120 Vac
RXM2AB2F7
0.037 (0.082)
RXM3AB2F7
0.037 (0.082)
RXM4AB2F7
0.037 (0.082)
230 Vac
RXM2AB2P7
0.037 (0.082)
RXM3AB2P7
0.037 (0.082)
RXM4AB2P7
0.037 (0.082)
0.037 (0.082)
Miniature relays with LED only (sold in lots of 10)
RXM4AB2F7
12 Vdc
RXM2AB3JD
0.037 (0.082)
–
–
RXM4AB3JD
24 Vdc
RXM2AB3BD 0.037 (0.082)
–
–
RXM4AB3BD 0.037 (0.082)
110 Vdc
RXM2AB3FD 0.037 (0.082)
–
–
RXM4AB3FD 0.037 (0.082)
125 Vdc
–
–
–
RXM4AB3GD 0.037 (0.082)
–
24 Vac
RXM2AB3B7
0.037 (0.082)
–
–
RXM4AB3B7
0.037 (0.082)
48 Vac
RXM2AB3E7
0.037 (0.082)
–
–
RXM4AB3E7
0.037 (0.082)
120 Vac
RXM2AB3F7
0.037 (0.082)
–
–
RXM4AB3F7
0.037 (0.082)
230 Vac
RXM2AB3P7
0.037 (0.082)
–
–
RXM4AB3P7
0.037 (0.082)
Specifications
page 4
References:
page 6
RXM2AB3F7
Introduction:
page 2
6
Dimensions:
page 9
Wiring:
page 12
References (continued)
Zelio™ Plug-In Relays
RXM miniature relays
Miniature relays with low level contacts, lockable test button only (sold in lots of 10)
Control
circuit
voltage
Number and type of
contacts Thermal current
(Ith)
4 C/O - 3 A
Unit
reference
V
RXM4GB1BD
Weight
kg (lb)
12 Vdc
RXM4GB1JD 0.037 (0.082)
24 Vdc
RXM4GB1BD 0.037 (0.082)
48 Vdc
RXM4GB1ED 0.037 (0.082)
110 Vdc
RXM4GB1FD 0.037 (0.082)
24 Vac
RXM4GB1B7 0.037 (0.082)
48 Vac
RXM4GB1E7
0.037 (0.082)
120 Vac
RXM4GB1F7
0.037 (0.082)
230 Vac
RXM4GB1P7
0.037 (0.082)
Miniature relays with low level contacts, with LED and lockable test button (sold in lots of 10)
RXM4GB2BD
12 Vdc
RXM4GB2JD 0.037 (0.082)
24 Vdc
RXM4GB2BD 0.037 (0.082)
48 Vdc
RXM4GB2ED 0.037 (0.082)
110 Vdc
RXM4GB2FD 0.037 (0.082)
24 Vac
RXM4GB2B7 0.037 (0.082)
48 Vac
RXM4GB2E7
0.037 (0.082)
120 Vac
RXM4GB2F7
0.037 (0.082)
230 Vac
RXM4GB2P7
0.037 (0.082)
240 Vac
RXM4GB2U7 0.037 (0.082)
Miniature relays with low level contacts, with LED only (sold in lots of 10)
RXM4GB3F7
Introduction:
page 2
12 Vdc
RXM4GB3JD 0.037 (0.082)
24 Vdc
RXM4GB3BD 0.037 (0.082)
48 Vdc
RXM4GB3ED 0.037 (0.082)
110 Vdc
RXM4GB3FD 0.037 (0.082)
24 Vac
RXM4GB3B7 0.037 (0.082)
48 Vac
RXM4GB3E7
0.037 (0.082)
120 Vac
RXM4GB3F7
0.037 (0.082)
230 Vac
RXM4GB3P7
0.037 (0.082)
Specifications
page 4
References:
page 6
Dimensions:
page 9
Wiring:
page 12
7
References (continued)
Zelio™ Plug-In Relays
RXM miniature relays
Sockets
Contact terminal
arrangement
Mixed
Sold in
lots of
10
Unit
reference
RXZE2M114 (1)
Weight
kg (lb)
0.048 (0.106)
10
RXZE2M114M (1)
0.056 (0.124)
10
RXZE2S114S (2)
0.070 (0.154)
10
10
10
RXZE2S108M (2)
RXZE2S111M (1)
0.058 (0.128)
0.066 (0.146)
0.070 (0.154)
For
use with
Sold in
lots of
Unit
reference
V
6...250 Vdc
All sockets
20
RXM040W
kg (lb)
0.003 (0.007)
RC circuit
24...60 Vac
110...240 Vac
All sockets
All sockets
20
20
RXM041BN7
RXM041FU7
0.010 (0.022)
0.010 (0.022)
Varistor
6...24 Vac / Vdc
24...60 Vac / Vdc
110...240 Vac / Vdc
All sockets
All sockets
All sockets
20
20
20
RXM021RB
RXM021BN
RXM021FP
0.003 (0.007)
0.003 (0.007)
0.003 (0.007)
Separate
RXZE2M114M
+
Relay RXM4AB1F7
Connection
Relay type
Screw clamp terminals RXM2pppp (3)
RXM4pppp
Screw connector
RXM2pppp (3)
RXM4pppp
Spring clamp terminals RXM2pppp (3)
RXM4pppp
Box lug connector
RXM2pppp
RXM3pppp
RXM4pppp
RXZE2S114M (1)
Protection modules
Description
Diode
RXM041pp7
Voltage
Weight
Timing relays
Description
2 or 4 timed C/O contacts
For
use with
Sockets RXZEppppp
Unit
reference
REXL2pp (4)
REXL4pp (4)
Accessories
Description
REXL4pp
RXZ400
For
use with
Metal hold-down clip
All sockets
Plastic hold-down ejector clip All sockets
Bus jumper 2-pole (Ith: 5 A)
All sockets with separate contacts
Sold in
lots of
10
10
10
Unit
reference
RXZ400
RXZR335
RXZS2
Weight
kg (lb)
0.001 (0.002)
0.005 (0.011)
0.005 (0.011)
Mounting adapter
for DIN rails (5)
Mounting adapter
with mounting lugs for panel
Clip-in ID tags
All relays
10
RXZE2DA
0.004 (0.009)
All relays
10
RXZE2FA
0.002 (0.004)
All relays (sheet of 108 legends)
10
All sockets except RXZE2M114 and RXZE2S114S 10
RXZE2S114S socket
10
RXZL520
RXZL420
RSZL300
0.080 (0.176)
0.001 (0.002)
0.001 (0.002)
(1)Thermal current Ith: 10A
(2)Thermal current Ith: 12A
(3)When mounting relay RXM2ppppp on socket RXZE2Mpppp, the thermal current must not exceed 10A.
(4) Please consult the "Zelio Time timing relays" catalog.
(5)Test button becomes inaccessible if used with DIN rail mounting adapter or panel mounting adapter and terminals face the user.
8
Zelio™ Plug-In Relays
Dimensions
RXM miniature relays
Dimensions
Miniature relays
RXMpppppp
Common view
RXM2
Pin side view
mm
in.
RXM3
RXM4
6.6 6.6
4.4 4.4 4.4
0.17 0.17 0.17
27
1.06
6.3 6.3 4.2 4.2
0.25 0.25 0.170.17
0.26 0.26
21
9
0.35
40
1.58
6
0.24
21
0.83
2.5
0.10
21
2.5
0.10
13.2
0.52
2.5
0.10
2.5
0.10
13.2
0.52
2.5
0.10
4.4
0.17
2.5
0.10
13.2
0.52
Sockets
RXZE2M114M
(4)
34
8
7
6
42
32
22 12
4
3
2
32
22
12
4
3
2
1
11
(2)
A2
14
A1
13
31
12
3.5
0.14
Common side view
(2)
(3)
A2
A1
21
41
31
21
13
11
10
12
11
10
9
(4)
21
0.83
30
1.18
23.5
0.93
27
1.06
50
67 1.97
2.64
7
0.28
RXZE2S111M
41
12
11
9
31
44
8
14
5
34
42
4
12
1
32
6
21
24
11
8
RXZE2S114M
14
5
22
41
31
21 11
7
12
44
11
34
10 9
24 14
4
8
42
7
32
6
5
22 12
4
3
2
12
2
1
3.5
0.14
(5)
29
1.14
A2
A1
14
13
3.5
0.14
A2
A2
A1
14
13
3.5
0.14
A1
14
23.5
0.93
27
1.06
23.5
0.93
27
1.06
1
38
1.50
38
1.50
79
3.11
9
3
3.5
0.14
(2)
70
2.76
1
19
0.75
(1)
23
0.91
5
3.5
0.14
14
RXZE2S108M
61
2.40
mm
in.
11
9
(1)
24 14
38
1.50
69
2.72
9
30 0.35
1.18
3.5
0.14
23
0.91
7
0.28
7
0.28
44
14
5
42
41
(3)
24
6
44
8
39.5
1.56
(3)
34
7
79
3.11
61
2.40
(1)
43
1.69 17
0.67
mm
in.
25.5
1.00
80
3.15
40
1.58 19
0.75
mm
in.
40
1.58
RXZE2M114
13
23.5
0.93
27
1.06
(1)Relays
(2)Protection module
(3)Metal hold-down clip
(4)2 elongated holes Ø 3.5 x 6.5
(5)2 bus jumpers
Introduction:
page 2
Specifications
page 4
References:
page 6
Dimensions:
page 9
Wiring:
page 12
9
Zelio™ Plug-In Relays
Dimensions (continued)
RXM miniature relays
Dimensions (continued)
Sockets (continued)
RXZE2S114S Socket only
RXZE2S114S Socket with RXM relay and retention clip
35.5
1.40
mm
in.
31
1.22
22
0.87
29.5
1.16
23.5
0.93
31
1.22
98
3.86
28
1.10
(1)
(3)
94
3.70
90
3.54
15
0.59
7.5
0.30
94
3.70
mm
in.
48
1.89
(2)
(4)
28
1.10
1.2
0.05
(1) Relay
(2) Protection module
(3) Metal retention clip
(4) I.D. tag
52
2.05
70
2.76
76
2.99
RXZE2S114S Socket with RXM relay and ejector clip
94
3.70
31
1.22
98
3.86
mm
in.
(1)
(3)
(2)
28
1.10
(1) Relay
(2) Protection module
(3) Ejector clip
(4) I.D. tag
Plastic ejector clip RXZR335
52
2.05
70
2.76
80
3.15
Metal retention clip RXZ400
22
0.87
57
2.24
ID tag RSZL300
27
1.06
8.0
0.3
(4)
42
1.65
7.2
0.3
14.5
0.6
0.8
0.03
Introduction:
page 2
10
Specifications
page 4
References:
page 6
Dimensions:
page 9
Wiring:
page 12
Zelio™ Plug-In Relays
Dimensions (continued)
RXM miniature relays
Dimensions (continued)
Plastic hold-down clip and clip-in ID tags
RXZR335
RXZL420
57
2.24
Mounting on all sockets (1)
14,2
(1)
94,5
27
1.06
12
26,5
81
(1) Clip-in ID tags for all sockets except
RXZE2M114
Bus jumper
Metal hold-down clip
RXZS2
Mounting on sockets with separate contacts
(view from below)
Example of bus jumper mounting on sockets
RXZ400
22
0.87
7,3
2,2
25
22
(1)
(1)
2,3
42
1.65
(2)
(2)
0.8
0.03
(1)2 bus jumpers (polarity A2)
(2)2 bus jumpers (polarity A1)
Mounting adapter for panel
RXZE2DA
RXZE2FA
38
43
48
38
Mounting adapter for rails (1)
6
3
3,5
3,5
48
4
4
49
24
24
23
51
(1)Test button becomes inaccessible
Introduction:
page 2
Specifications
page 4
References:
page 6
Dimensions:
page 9
Wiring:
page 12
11
Zelio™ Plug-In Relays
Wiring diagrams
RXM miniature relays
Wiring diagrams
Miniature relays
A2
A1
42
44
41
34
32
31
24
22
21
14
12
A2
A1
11
34
32
31
24
22
RXM4ppppp
21
14
12
A2
A1
11
44
42
RXM3ppppp
41
14
11
12
RXM2ppppp
1
4
1
2
3
1
2
3
4
12
5
42
8
12
22
32
4
5
6
12
5
22
6
32
7
42
8
14
9
44
12
14
7
24
8
34
9
14
9
24
10
34
11
44
12
11
13
41
14
21
21
31
41
14
A2
31
14
11
13
A1
11
13
A1
A1
A2
A2
Symbols shown in black correspond to IEC markings; blue correspond to NEMA markings.
Sockets
RXZE2M114
4
42
RXZE2M114M
6
7
34 24
8
5
44 14
3
2
1
32 22 12
RXZE2S108M
8
44
7
6
34 24
5
14
4
42
3
32
1
12
1
2
22
12
41
8
44
9
11
5
14
4
42
1
12
5
9
14
A2
12
41
13
A1
11
31
9
11
10
21
14
13
A2
14
41 31
12 11
A1
13
21
10
A1
A2
14
A2
11
9
13
INPUT A1
Symbols shown in black correspond to IEC markings; blue correspond to NEMA markings.
RXZE2S111M
RXZE2S114M
9
31
6
34
8
21
5
24
7
11
4
14
3
32
2
22
1
12
A1
A2
14
A2
12
41
8
44
4
42
11
31
7
34
3
32
RXZE2S114S
10
21
6
24
2
22
14
A2
41
12
31
11
21
10
11
9
44
8
34
7
24
6
14
5
42
4
32
3
22
2
12
1
A1
A2
13
INPUT A1
9
11
5
14
1
12
13
INPUT A1
A2
A1
14
13
A2
14
A1
13
Symbols shown in black correspond to IEC markings; blue correspond to NEMA markings.
Protection modules
RXM040W
RXM041ppp
RXM021ppp
– A2
– A2
– A2
+ A1
+ A1
+ A1
Introduction:
page 2
12
Specifications
page 4
References:
page 6
Dimensions:
page 9
Wiring:
page 12
9 ~ 11
0.35 ~ 0.43
mm
in.
(2)
™
Zelio
Plug-In Relays
(1)
Wiring instructions
for RXZE2S114S socket
RXM miniature relays
9 ~ 11
0.35 ~ 0.43
mm
in.
9 ~ 11
0.35 ~ 0.43
mm
in.
Wiring instructions for RXZE2S114S socket
Recommended removal tool: flat blade,
parallel tip
F
2.5
0.098
Recommended wire strip length
mm
in.
2.5
0.098
mm
in.
Openings for wiring and removal tool
(1)
(1)
F
mm
in.
2.5
0.098
9 ~ 11
0.35 ~ 0.43
mm
in.
(2)
(2)
2.5
0.098
mm
in.
Wiring insertion
(1) Wiring opening
(2) Removal tool opening
2
1
(1)
(2)
Wiring removal
F
F
F
(1)
F
(2)
F
F
F
F
F
F
F
2
1
F
1
2 35.5
1.40
mm
in.
Note: Allow only one wire per terminal opening
2
15
0.59
1
F
F
F
48
1.89
F
F
F
F
F
1
4
3
F
2
F
3
F
F
1
2
3
4
3
1 Wiring (cable) terminal opening
2 Removal tool opening
4
1.2
0.05
F
F
F
1
2
F
94
3.70
90
3.54
2
F
F
F
1
4
3
7.5 2
0.30
28
1.10
29.5
1.16
23.5
1
0.93
Recommended wiring for
RXZE2S114S socket
F
Flexible wiring with 1 wire
0.5 to 1.5 mm2 – 20 to 16 AWG
F
cable end
2 wires 0.5 to 1.5 mm2 – 20 to 16 AWG
F
0.5 to 1.5 mm2 – 20 to 16 AWG
Solid wiring without 1 wire
cable end
F 2 – 20 to 16 AWG
2 wiresF 0.5 to 1.5 mm
F
2 31
1.22
22
0.87
1
1
Introduction:
page 2
2
Specifications
page 4
References:
page 6
Dimensions:
page 9
Wiring:
page 12
13
For additional information about our currently stocked
products or to place an order, please contact your local
Viking Electric Supply sales representative.
www.vikingelectric.com
www.schneider-electric.com
Schneider Electric USA, Inc.
8001 Knightdale Blvd.
Knightdale, NC 27545
USA Customer Care Center
Tel: 888-778-2733
Schneider Electric Canada
5985 McLaughlin Rd.
Missassauga, Ontario, Canada L5R 1B8
Canada Customer Care Center
Tel: 800-565-6699
The information and dimensions in this catalog are provided for the convenience of our customers.
While this information is believed to be accurate, Schneider Electric reserves the right to make
updates and changes without prior notification and assumes no liability for any errors or omissions.
Zelio, Schneider Electric and logo, and “Make the most of your energy” are trademarks or
registered trademarks of Schneider Electric or its affiliates in the United States and other
countries. Other trademarks used herein are the property of their respective owners.
Design: Schneider Electric
Photos: Schneider Electric
8501DB1301
© 2013–2014 Schneider Electric. All rights reserved.
5/2014