Many to Many: Standard Capacity Product (SCP) Availability Calculations Radha Madrigal Customer Service Department August 18, 2014 Agenda • • • • • Background New outage classifications in OMS Sample outages for RA resources Changes to RAAM New variables for settlements & billing Page 2 ISO PUBLIC © 2014 CAISO Background Page 3 ISO PUBLIC © 2014 CAISO Many to Many Initiative Timeline • Fall 2014 – October 1, 2014 – Many to Many: SCP Availability Calculations – (to coincide with OMS activation) • Spring 2015 – Maintenance Release – Many to Many Substitution/App Consolidation ISO PUBLIC © 2014 CAISO Standard Capacity Product (SCP) Availability Calculations • The ISO reviews the availability of each Resource Adequacy (RA) resource subject to SCP each month to determine whether it meets the applicable availability standard • With the introduction of the Outage Management System (OMS), newly defined outage categories impact the settlement of SCP • Outage MWs associated with approved forced outages that are not subject to SCP shall be exempted within the SCP pre-calculation configuration Page 5 ISO PUBLIC © 2014 CAISO New Outage Classifications in OMS Page 6 ISO PUBLIC © 2014 CAISO New Fields in OMS • Opportunity – Off Peak Opportunity – Short Notice Opportunity • SCP Exempt Flag – The exempt MW capacity is not part of the availability assessment – Automatically set in OMS based on business rules • Nature of Work ISO PUBLIC © 2014 CAISO When is the SCP Exempt Flag Set? Outage Type Difference between date of outage submission and planned start date/time of outage * SCP Exempt Flag is set Forced 4-7 calendar days Yes Forced 3 calendar days or less No Planned N/A No (*excluding the date outage was submitted and planned start date of outage) Page 8 ISO PUBLIC © 2014 CAISO Forced Outage Types Outage Type Does Curtailment reduce Availability MW Is Curtailment MW considered Exempt in SCP Availability Calculation? MW in Calculation? Nature of Work Environmental Restrictions Transmission Induced Plant Maintenance Plant Trouble Ambient Due to Temperature Ambient Not Due to Temperature Power System Stabilizer (PSS) AVR/Exciter Unit Testing Metering/Telemetry RTU/RIG ICCP Transitional Limitation Unit Cycling Unit Supporting Startup Use Limit Reached Unit Pre Commercial Testing N N Y Y Y N N N N N N N Y Y Y Y Y N N Y N N Y N N N N N N N N N N N N N N Y Y Y Flag Type Short Notice Opportunity Flag Off Peak Opportunity Flag SCP Exempt Flag ISO PUBLIC © 2014 CAISO Sample Outages for RA Resources Page 10 ISO PUBLIC © 2014 CAISO Weighted Average Calculation Outage OF1 Total (per outage): Final Curtailment (weighted average): OF1 RESOURCE RESA Outage Type Forced Pmax 100 RA Obligation Curtailment 100 50 Forced 100 100 MWMinutes Minute 60 3000 60 3000 50 Availability Exempt (MW) (MW) 50 0 • RAAM will report 50 MW of availability for this hour Page 11 ISO PUBLIC © 2014 CAISO Overlapping Outages & SCP Exempt • Two outages for the same hour and resource Outage Outage Type OF1 Forced OF2 (Exempt) Forced Total (per outage): OF1 Total (per outage): OF2 (Exempt) Final Curtailment (weighted average): OF1 Forced Final Curtailment (weighted average): OF2 (Exempt) Forced RESOURCE RESA Pmax 100 100 RA Obligation Curtailment Minutes 100 50 60 100 50 60 60 60 100 100 50 100 100 50 <-SCP exempt MW MWMinute 3000 3000 3000 3000 Availability Exempt (MW) (MW) 50 50 • RAAM will report 50 MW of availability and 50 exempt MW for this hour Page 12 ISO PUBLIC © 2014 CAISO Changes to Resource Adequacy Availability Management (RAAM) Page 13 ISO PUBLIC © 2014 CAISO Changes to RAAM • The Resource Adequacy Availability Management (RAAM) application was updated to accommodate the new outage classifications in the Outage Management System (OMS) • New rules engine for SCP availability calculation • Old rules engine still available for historic data • User interface changes for SCP calculations and CPM calculations Page 14 ISO PUBLIC © 2014 CAISO Query SCP Calculations • Select New SCP Calculation checkbox to display run output for the new SCP availability calculation engine • Enter start date and end date • Select the checkbox next to Resources “All” or select specific resources from the multi-select box • Click Query to view the calculations Page 15 ISO PUBLIC © 2014 CAISO SCP Calculations – Outages Tab • Details related to the resource outage • Asterisks identify outages excluded due to outage correction Page 16 ISO PUBLIC © 2014 CAISO SCP Calculations – Details Tab • Parameters related to resource availability Page 17 ISO PUBLIC © 2014 CAISO SCP Calculations – Values Tab • Resource level information that is used for settlements purposes • Shows final availability and the exempt MW at the resource-hour granularity, that will be used for SCP settlements Page 18 ISO PUBLIC © 2014 CAISO Query CPM Calculations • Select New CPM Calculation checkbox to display run output for the CPM availability calculation • Enter start date and end date • Select the checkbox next to Resources “All” or select specific resources from the multi-select box • Click Query to view the calculations Page 19 ISO PUBLIC © 2014 CAISO CPM Calculations – Outages Tab • Details related to the resource outage • Asterisks identify outages excluded due to outage correction Page 20 ISO PUBLIC © 2014 CAISO CPM Calculations – Details Tab • Parameters related to resource availability Page 21 ISO PUBLIC © 2014 CAISO CPM Calculations – Values Tab • Resource level information that is used for settlements related purposes. • Shows Final Planned and Forced Availability at the resource-hour granularity, that will be used for CPM settlements Page 22 ISO PUBLIC © 2014 CAISO New Variables for Settlements & Billing Page 23 ISO PUBLIC © 2014 CAISO BPM Configuration Guide: Standard Capacity Product Pre-calculation (Schedule) • Updated version of the configuration guide is going through change management process • Proposed changes can be accessed under PRR 752 • Will be discussed at BPM stakeholder meeting on August 26th ISO PUBLIC © 2014 CAISO BPM Configuration Guide: Standard Capacity Product Pre-calculation (Updated Business Rules) • SCP exempt capacity MWs shall not be subject to SCP Non-Availability Charges and Availability Payments. • A resource’s MW Capacity entered into a grandfathered contract as specified in Tariff Section 40.9.2(2) & (3) shall be treated as SCP exempt capacity. • Outage MW Capacity associated with an RA maintenance outage or short-notice opportunity outage that is approved as a forced outage not subject to SCP shall be treated as SCP exempt capacity. Page 25 ISO PUBLIC © 2014 CAISO New Input Variable Name • BARAResourceOutageExemptQuantity BrtF’S’mdh • Outage Exempt Quantity represents the RA Capacity exempt from SCP due to: – RA Maintenance outage – Off-Peak Opportunity RA Maintenance Outage – Short Notice Opportunity Outage Page 26 ISO PUBLIC © 2014 CAISO New Output Variable Name • BAHourlyRAResourceSCPCapacityNonExemptQuan tity BrtF’S’mdh – Eligible Capacity that is not exempted • Replaces the following: BAHourlyRAResourceSCPCapacityNotGrandfatheredQu antity BrtF’S’mdh – Eligible capacity that is not grandfathered by Business Associate B and resources r and Resource Type t Page 27 ISO PUBLIC © 2014 CAISO Questions? • [email protected] • Updated RAAM user guide: http://www.caiso.com/Documents/ResourceAdequacyAv ailabilityManagementDraftToolUserGuide_MarketParticip ants.pdf • Additional Training Opportunity: Fall 2014 Release Settlements Training on August 27th ISO PUBLIC © 2014 CAISO Appendix Page 29 ISO PUBLIC © 2014 CAISO Overlapping Forced Outages Outage Type Forced Forced Ambient due to Temp (counted for availability) Ambient due to Temp (counted for availability) SNOO SNOO Planned Planned Pmax 100 100 RA Obligation Curtailment Minutes 100 15 30 100 20 30 100 100 0 15 0 100 100 100 100 100 100 100 100 100 100 10 10 15 0 10 45 15 45 42 18 60 60 60 60 450 150 675 0 180 1050 450 825 180 OF1 Forced 100 100 17.5 OF2 Nature of work 100 100 7.5 OF3 SNOO 100 100 13.75 OP1 Planned 100 100 3 Outage OF1 OF1 OF2 Total (per outage): Total (per outage): Total (per outage): Total (per outage): Final Curtailment (weighted average): Final Curtailment (weighted average): Final Curtailment (weighted average): Final Curtailment (weighted average): OF2 OF3 OF3 OP1 OP1 OF1 OF2 OF3 OP1 RESOURCE RESA MWMinute 450 600 Availability Exempt (MW) (MW) 75 13.75 Page 30 ISO PUBLIC © 2014 CAISO
© Copyright 2024 ExpyDoc