Local regulations may restrict the use of this product to below the conditions quoted. In the interests of development and improvement of the product, we reserve the right to change the specification without notice. © Copyright 2014 TI-P339-01 MI Issue 1 VLF Vortex Flowmeter Description The VLF multivariable vortex flowmeter utilizes three primary sensing elements to measure the mass flowrate of a range of fluids and gases: - Vortex shedding velocity sensor, - RTD temperature sensor, - Solid-state pressure transducer. VLF range and benefits - V The VLF-V delivers a direct reading of volumetric flowrate in applications ranging from general water flows to hydrocarbon fuel flow measurement. - T The VLF-T integrates a precision 1000 Ω platinum RTD temperature sensor that can be used to calculate and output a compensated mass reading. This device is typically used to measure flowrates of saturated steam. - P The VLF-P offers flow computer functionality in a compact field device. This multivariable instrument incorporates temperature and pressure sensors to provide an instantaneous reading of compensated mass flowrate of gases, liquids and steam. In addition to outputs for totalized mass and alarm settings, the field-configurable electronics deliver up to three analogue 4-20 mA outputs of five process measurements, including volumetric flowrate, mass flowrate, pressure and density. VLF 3 1 Sizes and pipe connections Flanged DN25, DN50, DN80, DN100, DN150, DN200 Flanged EN 1092-1 PN40 and PN100 connections or 1", 2", 3", 4", 6" and 8" Flanged ASME 16.5 Class 150, 300 and 600 connections. Wafer type DN25, DN50, DN80, DN100 suitable for fitting between EN 1092-1 PN40 flanges or 1", 2", 3" and 4" suitable for fitting between ASME B16.5 Class 300 flanges. Pressure / temperature limits See page 2 Materials No. Part Material 1 Flowmeter body and flanges 316L stainless steel 2 Thread sealant (model 'P' only) DuPontTM Teflon ® 3 Electronics enclosure Die cast aluminium Page 1 of 6 Pressure / temperature limits Flanged EN 1092-1 PN40 and PN100 A C Temperature °C The product must not be used in this region or beyond the parameter of the PMA or TMA of the relative end connection. Only the high temperature version can be used in this region. A - B Flanged EN 1092-1 PN100 B Steam saturation curve A - C Flanged EN 1092-1 PN40 C B Pressure bar g EN 1092-1 PN40 PN100 Body design conditions PMA Maximum allowable pressure TMA Maximum allowable temperature 40 bar g @ 50°C Maximum operating pressure for saturated steam service TMO Maximum operating temperature for saturated steam service Maximum process temperature ASME Class 300 230 psi g @ 100°F 600 psi g @ 100°F 1200 psi g @ 100°F 750°F @ 94 psi g 750°F @ 352 psi g 750°F @ 705 psi g -200°C -328°F -328°F -328°F 30 bar g 70 bar g 170 psi g 420 psi g 800 psi g 236°C 287°C 375°F 452°F 520°F Standard version 260°C 500°F High temp. version 400°C 750°F -200°C -328°F Storage -40 to 60°C -40 to 140°F Operating -40 to 85°C -40 to 185°F Designed for a maximum cold hydraulic test pressure of Class 600 -200°C Minimum process temperature Electronic ambient temperature range 100 bar g @ 50°C 400°C @ 25.7 bar g 400°C @ 64.2 bar g Minimum allowable temperature PMO Class 150 60 bar g 150 bar g 345 psi g 900 psi g 1800 psi g Flanged ASME 16.5 Class 150, 300 and 600 Pressure psi g A A - D Flanged ASME 16.5 Class 600 D Temperature °F Only the high temperature version can be used in this region. E Temperature °C The product must not be used in this region or beyond the parameter of the PMA or TMA of the relative end connection. Steam saturation curve A - E Flanged ASME 16.5 Class 300 A - F Flanged ASME 16.5 Class 150 F E D Pressure bar g TI-P339-01 MI Issue 1 VLF Vortex Flowmeter Page 2 of 6 Dimensions / weights (approximate) Metric units Flanged models 114 (4.49") 135 (5.31") 81 (3.19") H Size L H DN25 200 DN50 Weights kg PN40 PN100 344 7.5 10.0 200 363 11.0 16.2 DN80 200 377 15.4 22.2 DN100 250 390 20.5 31.5 DN150 300 417 35.8 67.5 DN200 300 442 61.0 108.0 Imperial units Flanged model Flanged models 150 ASME 300 600 13.54" 14.8 17.0 17.9 7.87" 14.29" 23.1 24.3 30.9 3" 7.87" 14.84" 32.8 40.8 46.5 4" 9.84" 15.35" 45.4 63.1 86.0 6" 11.81" 16.42" 69.7 106.5 170.2 8" 11.81" 17.40" 106.5 156.5 255.7 Size L Weights lb L H 1" 7.87" 2" Metric units Wafer models 114 (4.49") 135 (5.31") 81 (3.19") Weights kg Size L H PN40 DN25 65 346 5.2 DN50 65 358 6.7 DN80 65 375 9.0 DN100 65 387 11.0 Imperial units H Wafer models Wafer model Size L TI-P339-01 MI Issue 1 Weights lb L H ASME 300 1" 2.56" 13.62" 11.5 2" 2.56" 14.09" 14.8 3" 2.56" 14.76" 19.8 4" 2.56" 15.24" 24.3 VLF Vortex Flowmeter Page 3 of 6 Technical data Sizing IP rating IP65 / NEMA 4 Power supply L Output Loop powered Piping Conditions: loop powered 12 - 36 Vdc Pipe diameter 'D' Condition 1 x 4 - 20 mA, HART ® 1 x pulse passive Performance Accuracy Upstream Downstream 1 x 90° elbow before flowmeter 10D 5D 2 x 90° elbows before flowmeter 15D 5D 2 x 90° elbows before flowmeter, out of plane 25D 5D Reduction before flowmeter 10D 5D Process variables Liquids Gas and Steam Mass flowrate ±1% of rate ±1.5% of rate Volumetric flowrate ±0.7% of rate ±1% of rate Expansion before flowmeter 20D 5D Temperature ±1°C (±2°F) ±1°C (±2°F) Partially open valve 25D 5D Pressure ±0.3% of full-scale ±0.3% of full-scale Density ±0.3% of reading ±0.5% of reading Repeatability Velocity (v) range: Maximum velocity, liquid: Minimum velocity, liquid: 30 feet / second (9.0 metres / second) 1 foot / second (0.3 metres / second) Mass flowrate ±0.2% of rate Volumetric flowrate ±0.1% of rate Temperature ±0.1°C (±0.2°F) Maximum velocity, steam: 110 feet / second ( 35 metres / second) Pressure ±0.05% of full-scale Minimum velocity, gas or steam: Density ±0.1% of reading Maximum velocity, gases: 300 feet / second ( 90 metres / second) v min = 6.1 metres per second density (kg / m3) v min = 5 feet per second density (lb / ft3) Water minimum and maximum flowrates Nominal pipe size (mm) Flowrate 25 50 80 100 150 200 m3 / h minimum 0.5 2.1 4.7 8.1 18 32 m3 / h maximum 15 63 140 244 554 970 Nominal pipe size (inches) TI-P339-01 MI Issue 1 Flowrate 1" 2" 3" 4" 6" 8" Gal minimum 2.2 9.2 21 36 81 142 Gal maximum 67 276 618 1 076 2 437 4 270 VLF Vortex Flowmeter Page 4 of 6 Saturated steam (kg / h) Minimum Maximum Minimum Maximum Minimum Maximum Minimum Maximum Minimum Maximum Minimum Maximum 25 mm 8 30 18 162 24 287 29 412 33 537 40 790 50 mm 32 125 75 664 99 1180 119 1691 136 2204 165 3243 Nominal pipe size 80 mm 100 mm 72 126 279 486 167 290 1485 2585 222 387 2638 4592 266 463 3782 6583 304 529 4929 8579 369 642 7254 12627 150 mm 286 1103 658 5860 877 10412 1050 14926 1199 19452 1455 28628 200 mm 500 1932 1153 10266 1537 18240 1840 26148 2100 34075 2548 50150 Minimum Maximum Minimum Maximum Minimum Maximum Minimum Maximum Minimum Maximum Minimum Maximum 25 mm 9 142 21 847 29 1554 34 2265 40 2979 48 4414 50 mm 36 584 87 3476 117 6381 142 9299 162 12229 198 18119 Nominal pipe size 80 mm 100 mm 79 138 1307 2275 194 337 7775 13533 262 457 14273 24844 317 551 20801 36205 363 632 27354 47612 442 770 40529 70544 150 mm 313 5157 764 30682 1035 56329 1250 82087 1434 107949 1745 159942 200 mm 549 9034 1339 53749 1814 98676 2190 143801 2511 189105 3057 280187 Pressure 0 bar g flowrates 5 bar g 10 bar g Metric 15 bar g 20 bar g 30 bar g Pressure 0 bar g Typical 5 bar g 10 bar g 15 bar g 20 bar g 30 bar g Air (nm3 / h) at 20°C Saturated steam (lb / h) Minimum Maximum Minimum Maximum Minimum Maximum Minimum Maximum Minimum Maximum Minimum Maximum 1" 20 88 46 462 62 842 74 1221 85 1605 95 1996 2" 82 362 187 1897 253 7728 304 11214 349 14741 389 18329 Nominal pipe size 3" 4" 183 318 810 1410 419 728 4243 7385 565 983 7728 13451 680 1184 13451 19519 780 1358 22657 22657 870 1514 31903 31903 6" 722 3198 1652 16744 2229 30498 2685 44254 3079 58172 3433 72334 8" 1264 5602 2893 29333 3905 53426 4704 77525 5393 101906 6014 126716 Minimum Maximum Minimum Maximum Minimum Maximum Minimum Maximum Minimum Maximum Minimum Maximum 1" 5 90 15 704 21 1322 25 1944 29 2568 33 3195 2" 22 369 63 2890 86 5427 104 7978 120 10542 134 13115 Nominal pipe size 3" 4" 50 87 826 1437 141 245 6466 11254 193 335 12140 21131 234 407 17847 31064 269 467 23580 41043 300 521 28034 51063 6" 198 3258 555 25515 761 47911 922 70431 1060 93057 1182 115775 8" 347 5708 972 44698 1332 83931 1615 123375 1857 163000 2071 203000 Pressure flowrates 5 psi g 100 psi g Imperial 200 psi g 300 psi g 400 psi g 500 psi g Typical Pressure 5 psi g 100 psi g 200 psi g 300 psi g 400 psi g 500 psi g TI-P339-01 MI Issue 1 Air (SCFM) at 70°F VLF Vortex Flowmeter Page 5 of 6 How to order Selection: Category Description Suffix Code Flowmeter Vortex type VLF Electronics Volume measurement of liquids, gases and steam V Flow velocity including temperature sensor T Flow velocity including temperature and pressure sensor P Flanged Body type and size Wafer Flanged Connection Wafer DN25 1" 25 DN50 2" 50 DN80 3" 80 DN100 4" 1H DN150 6" H5 DN200 8" 2H DN25 1" W3 DN50 2" W5 DN80 3" W6 DN100 4" W7 ASME Class 150 1 ASME Class 300 2 ASME Class 600 3 EN 1092-1 PN40 5 EN 1092-1 PN100 7 ASME Class 300 2 EN 1092-1 PN40 5 Grey = Standard VLF T 25 5 Mounting Compact including LCD L L Power supply 12 - 36 Vdc loop powered L L Output signal 1 x 4 - 20 mA, HART 1 x pulse passive 2 2 -200°C to 260°C (-330°F to 500°F) S -200°C to 400°C (-330°F to 750°F) H 'V' and 'T' options only No pressure sensor 0 2 bar a (30 psi a) Maximum test pressure 4 bar a (60 psi a) 1 7 bar a (100 psi a) Maximum test pressure 14 bar a (200 psi a) 2 20 bar a (300 psi a) Maximum test pressure 41 bar a (600 psi a) 3 34 bar a (500 psi a) Maximum test pressure 64 bar a (1 000 psi a) 4 100 bar a (1500 psi a) Maximum test pressure 175 bar a (2 500 psi a) 5 Process temperature ® Pressure sensor selection is dependent on the choice of electronics selected above Branding Selection example: 'P' option only VLF - T - 25 5 - L L 2 S - S 0 O Spirax Sarco - - O 0 - O How to order example: 1 off Spirax Sarco VLF-T-255-LL2S0-O vortex flowmeter for installation between EN 1092 PN40 flanges. TI-P339-01 MI Issue 1 VLF Vortex Flowmeter Page 6 of 6
© Copyright 2024 ExpyDoc