VLF Vortex Flowmeter

Local regulations may restrict the use of this product to below the conditions quoted.
In the interests of development and improvement of the product, we reserve the right to change the specification without notice. © Copyright 2014
TI-P339-01
MI Issue 1
VLF
Vortex Flowmeter
Description
The VLF multivariable vortex flowmeter utilizes three primary
sensing elements to measure the mass flowrate of a range of
fluids and gases:
- Vortex shedding velocity sensor,
- RTD temperature sensor,
- Solid-state pressure transducer.
VLF range and benefits
- V
The VLF-V delivers a direct reading of volumetric
flowrate in applications ranging from general water
flows to hydrocarbon fuel flow measurement.
- T
The VLF-T integrates a precision 1000 Ω platinum RTD
temperature sensor that can be used to calculate and
output a compensated mass reading. This device is
typically used to measure flowrates of saturated steam.
- P
The VLF-P offers flow computer functionality in a
compact field device. This multivariable instrument
incorporates temperature and pressure sensors to
provide an instantaneous reading of compensated
mass flowrate of gases, liquids and steam. In addition
to outputs for totalized mass and alarm settings,
the field-configurable electronics deliver up to
three analogue 4-20 mA outputs of five process
measurements, including volumetric flowrate, mass
flowrate, pressure and density.
VLF
3
1
Sizes and pipe connections
Flanged
DN25, DN50, DN80, DN100, DN150, DN200
Flanged EN 1092-1 PN40 and PN100 connections
or
1", 2", 3", 4", 6" and 8"
Flanged ASME 16.5 Class 150, 300 and 600 connections.
Wafer type
DN25, DN50, DN80, DN100
suitable for fitting between EN 1092-1 PN40 flanges
or
1", 2", 3" and 4"
suitable for fitting between ASME B16.5 Class 300 flanges.
Pressure / temperature limits
See page 2
Materials
No. Part
Material
1
Flowmeter body and flanges
316L stainless steel
2
Thread sealant (model 'P' only)
DuPontTM Teflon ®
3
Electronics enclosure
Die cast aluminium
Page 1 of 6
Pressure / temperature limits
Flanged EN 1092-1 PN40 and PN100
A
C
Temperature °C
The product must not be used in
this region or beyond the parameter
of the PMA or TMA of the relative
end connection.
Only the high temperature version
can be used in this region.
A - B Flanged EN 1092-1 PN100
B
Steam
saturation
curve
A - C Flanged EN 1092-1 PN40
C
B
Pressure bar g
EN 1092-1
PN40
PN100
Body design conditions
PMA Maximum allowable pressure
TMA Maximum allowable temperature
40 bar g @ 50°C
Maximum operating pressure
for saturated steam service
TMO
Maximum operating temperature
for saturated steam service
Maximum process
temperature
ASME
Class 300
230 psi g @ 100°F
600 psi g @ 100°F 1200 psi g @ 100°F
750°F @ 94 psi g
750°F @ 352 psi g
750°F @ 705 psi g
-200°C
-328°F
-328°F
-328°F
30 bar g
70 bar g
170 psi g
420 psi g
800 psi g
236°C
287°C
375°F
452°F
520°F
Standard version
260°C
500°F
High temp. version
400°C
750°F
-200°C
-328°F
Storage
-40 to 60°C
-40 to 140°F
Operating
-40 to 85°C
-40 to 185°F
Designed for a maximum cold hydraulic
test pressure of
Class 600
-200°C
Minimum process temperature
Electronic ambient
temperature range
100 bar g @ 50°C
400°C @ 25.7 bar g 400°C @ 64.2 bar g
Minimum allowable temperature
PMO
Class 150
60 bar g
150 bar g
345 psi g
900 psi g
1800 psi g
Flanged ASME 16.5 Class 150, 300 and 600
Pressure psi g
A
A - D Flanged ASME 16.5 Class 600
D
Temperature °F
Only the high temperature version
can be used in this region.
E
Temperature °C
The product must not be used in
this region or beyond the parameter
of the PMA or TMA of the relative
end connection.
Steam
saturation
curve
A - E Flanged ASME 16.5 Class 300
A - F Flanged ASME 16.5 Class 150
F
E
D
Pressure bar g
TI-P339-01 MI Issue 1
VLF Vortex Flowmeter
Page 2 of 6
Dimensions / weights (approximate)
Metric units
Flanged models
114
(4.49")
135
(5.31")
81
(3.19")
H
Size
L
H
DN25
200
DN50
Weights kg
PN40
PN100
344
7.5
10.0
200
363
11.0
16.2
DN80
200
377
15.4
22.2
DN100
250
390
20.5
31.5
DN150
300
417
35.8
67.5
DN200
300
442
61.0
108.0
Imperial units
Flanged model
Flanged models
150
ASME
300
600
13.54"
14.8
17.0
17.9
7.87"
14.29"
23.1
24.3
30.9
3"
7.87"
14.84"
32.8
40.8
46.5
4"
9.84"
15.35"
45.4
63.1
86.0
6"
11.81"
16.42"
69.7
106.5
170.2
8"
11.81"
17.40"
106.5
156.5
255.7
Size
L
Weights lb
L
H
1"
7.87"
2"
Metric units
Wafer models
114
(4.49")
135
(5.31")
81
(3.19")
Weights kg
Size
L
H
PN40
DN25
65
346
5.2
DN50
65
358
6.7
DN80
65
375
9.0
DN100
65
387
11.0
Imperial units
H
Wafer models
Wafer model
Size
L
TI-P339-01 MI Issue 1
Weights lb
L
H
ASME 300
1"
2.56"
13.62"
11.5
2"
2.56"
14.09"
14.8
3"
2.56"
14.76"
19.8
4"
2.56"
15.24"
24.3
VLF Vortex Flowmeter
Page 3 of 6
Technical data
Sizing
IP rating
IP65 / NEMA 4
Power
supply
L
Output
Loop
powered
Piping Conditions:
loop powered 12 - 36 Vdc
Pipe diameter 'D'
Condition
1 x 4 - 20 mA,
HART ® 1 x pulse passive
Performance
Accuracy
Upstream
Downstream
1 x 90° elbow
before flowmeter
10D
5D
2 x 90° elbows
before flowmeter
15D
5D
2 x 90° elbows
before flowmeter,
out of plane
25D
5D
Reduction
before flowmeter
10D
5D
Process variables
Liquids
Gas and Steam
Mass flowrate
±1% of rate
±1.5% of rate
Volumetric flowrate
±0.7% of rate
±1% of rate
Expansion
before flowmeter
20D
5D
Temperature
±1°C (±2°F)
±1°C (±2°F)
Partially open
valve
25D
5D
Pressure
±0.3% of full-scale
±0.3% of full-scale
Density
±0.3% of reading
±0.5% of reading
Repeatability
Velocity (v) range:
Maximum velocity, liquid:
Minimum velocity, liquid:
30 feet / second (9.0 metres / second)
1 foot / second (0.3 metres / second)
Mass flowrate
±0.2% of rate
Volumetric flowrate
±0.1% of rate
Temperature
±0.1°C (±0.2°F)
Maximum velocity, steam: 110 feet / second ( 35 metres / second)
Pressure
±0.05% of full-scale
Minimum velocity, gas or steam:
Density
±0.1% of reading
Maximum velocity, gases: 300 feet / second ( 90 metres / second)
v min =
6.1
metres per second
density (kg / m3)
v min =
5
feet per second
density (lb / ft3)
Water minimum and maximum flowrates
Nominal pipe size (mm)
Flowrate
25
50
80
100
150
200
m3 / h
minimum
0.5
2.1
4.7
8.1
18
32
m3 / h
maximum
15
63
140
244
554
970
Nominal pipe size (inches)
TI-P339-01 MI Issue 1
Flowrate
1"
2"
3"
4"
6"
8"
Gal
minimum
2.2
9.2
21
36
81
142
Gal
maximum
67
276
618
1 076
2 437
4 270
VLF Vortex Flowmeter
Page 4 of 6
Saturated steam (kg / h)
Minimum
Maximum
Minimum
Maximum
Minimum
Maximum
Minimum
Maximum
Minimum
Maximum
Minimum
Maximum
25 mm
8
30
18
162
24
287
29
412
33
537
40
790
50 mm
32
125
75
664
99
1180
119
1691
136
2204
165
3243
Nominal pipe size
80 mm
100 mm
72
126
279
486
167
290
1485
2585
222
387
2638
4592
266
463
3782
6583
304
529
4929
8579
369
642
7254
12627
150 mm
286
1103
658
5860
877
10412
1050
14926
1199
19452
1455
28628
200 mm
500
1932
1153
10266
1537
18240
1840
26148
2100
34075
2548
50150
Minimum
Maximum
Minimum
Maximum
Minimum
Maximum
Minimum
Maximum
Minimum
Maximum
Minimum
Maximum
25 mm
9
142
21
847
29
1554
34
2265
40
2979
48
4414
50 mm
36
584
87
3476
117
6381
142
9299
162
12229
198
18119
Nominal pipe size
80 mm
100 mm
79
138
1307
2275
194
337
7775
13533
262
457
14273
24844
317
551
20801
36205
363
632
27354
47612
442
770
40529
70544
150 mm
313
5157
764
30682
1035
56329
1250
82087
1434
107949
1745
159942
200 mm
549
9034
1339
53749
1814
98676
2190
143801
2511
189105
3057
280187
Pressure
0 bar g
flowrates
5 bar g
10 bar g
Metric
15 bar g
20 bar g
30 bar g
Pressure
0 bar g
Typical
5 bar g
10 bar g
15 bar g
20 bar g
30 bar g
Air (nm3 / h) at 20°C
Saturated steam (lb / h)
Minimum
Maximum
Minimum
Maximum
Minimum
Maximum
Minimum
Maximum
Minimum
Maximum
Minimum
Maximum
1"
20
88
46
462
62
842
74
1221
85
1605
95
1996
2"
82
362
187
1897
253
7728
304
11214
349
14741
389
18329
Nominal pipe size
3"
4"
183
318
810
1410
419
728
4243
7385
565
983
7728
13451
680
1184
13451
19519
780
1358
22657
22657
870
1514
31903
31903
6"
722
3198
1652
16744
2229
30498
2685
44254
3079
58172
3433
72334
8"
1264
5602
2893
29333
3905
53426
4704
77525
5393
101906
6014
126716
Minimum
Maximum
Minimum
Maximum
Minimum
Maximum
Minimum
Maximum
Minimum
Maximum
Minimum
Maximum
1"
5
90
15
704
21
1322
25
1944
29
2568
33
3195
2"
22
369
63
2890
86
5427
104
7978
120
10542
134
13115
Nominal pipe size
3"
4"
50
87
826
1437
141
245
6466
11254
193
335
12140
21131
234
407
17847
31064
269
467
23580
41043
300
521
28034
51063
6"
198
3258
555
25515
761
47911
922
70431
1060
93057
1182
115775
8"
347
5708
972
44698
1332
83931
1615
123375
1857
163000
2071
203000
Pressure
flowrates
5 psi g
100 psi g
Imperial
200 psi g
300 psi g
400 psi g
500 psi g
Typical
Pressure
5 psi g
100 psi g
200 psi g
300 psi g
400 psi g
500 psi g
TI-P339-01 MI Issue 1
Air (SCFM) at 70°F
VLF Vortex Flowmeter
Page 5 of 6
How to order
Selection:
Category
Description
Suffix Code
Flowmeter
Vortex type
VLF
Electronics
Volume measurement of liquids, gases and steam
V
Flow velocity including temperature sensor
T
Flow velocity including temperature and pressure sensor
P
Flanged
Body type and size
Wafer
Flanged
Connection
Wafer
DN25
1"
25
DN50
2"
50
DN80
3"
80
DN100
4"
1H
DN150
6"
H5
DN200
8"
2H
DN25
1"
W3
DN50
2"
W5
DN80
3"
W6
DN100
4"
W7
ASME Class 150
1
ASME Class 300
2
ASME Class 600
3
EN 1092-1 PN40
5
EN 1092-1 PN100
7
ASME Class 300
2
EN 1092-1 PN40
5
Grey = Standard
VLF T
25
5
Mounting
Compact including LCD
L
L
Power supply
12 - 36 Vdc loop powered
L
L
Output signal
1 x 4 - 20 mA, HART 1 x pulse passive
2
2
-200°C to 260°C (-330°F to 500°F)
S
-200°C to 400°C (-330°F to 750°F)
H
'V' and 'T'
options only
No pressure sensor
0
2 bar a (30 psi a)
Maximum test pressure 4 bar a (60 psi a)
1
7 bar a (100 psi a)
Maximum test pressure 14 bar a (200 psi a)
2
20 bar a (300 psi a)
Maximum test pressure 41 bar a (600 psi a)
3
34 bar a (500 psi a)
Maximum test pressure 64 bar a (1 000 psi a)
4
100 bar a (1500 psi a)
Maximum test pressure 175 bar a (2 500 psi a)
5
Process temperature
®
Pressure sensor
selection is dependent
on the choice of electronics
selected above
Branding
Selection example:
'P' option only
VLF
-
T
-
25
5
-
L
L
2
S
-
S
0
O
Spirax Sarco
-
-
O
0
-
O
How to order example: 1 off Spirax Sarco VLF-T-255-LL2S0-O vortex flowmeter for installation between EN 1092 PN40 flanges.
TI-P339-01 MI Issue 1
VLF Vortex Flowmeter