Data Sheet – Karra Model 1. Electrical Characteristics 1.1 Electrical Performance at Standard Test Conditions(*STC) 60Cells Panel Description Karra-240 Karra-245 Karra-250 Karra-255 Wp 240 245 250 255 Max. Power voltage (Vmp) V 29.6 29.8 30 30.2 Max. Power current (Imp) A 8.1 8.2 8.3 8.4 Open circuit voltage (Voc) V 37.3 37.5 37.7 37.9 Short circuit current (Isc) A 8.7 8.7 8.8 8.8 Panel efficiency % 13.8 14.1 14.4 14.6 Power tolerance % Item Max. Power (Pmax) Unit ±3 *STC(Standard Test Condition) : 1,000W/m², AM 1.5, 25℃ 1.2 Electrical Performance at Nominal Operating Cell Temperature Conditions(*NOCT) 60Cells Panel Description Karra-240 Karra-245 Karra-250 Karra-255 Wp 194 199 203 207 Max. Power voltage (Vmp) V 30.6 30.8 31.0 31.2 Max. Power current (Imp) A 6.4 6.4 6.5 6.6 Open circuit voltage (Voc) V 37.7 37.9 38.1 38.3 Short circuit current (Isc) A 7.0 7.0 7.0 7.0 Item Max. Power (Pmax) Unit *NOCT(Nominal Operating Cell Temperature) : 800W/m², 20℃, wind speed 1m/s 1.3 Dependence of Irradiance Page 5 - 1 Data Sheet – Karra Model 1.5 Thermal Characteristics Rating Unit Value NOCT ℃ 45±2 Isc %/℃ + 0.06 Voc %/℃ – 0.35 Pmax %/℃ – 0.42 Temperature Coefficient 1.6 AC Inverter(Optional) INPUT(DC) DATA P250LV-240 Recommended STC Panel Input Power Rating 235 W - 280 W Maximum Continuous Input Power 250 W Maximum Input Voltage 48 V MPPT Voltage Range 18 V - 37 V Maximum Power Voltage Range 25 V - 37 V Maximum DC Short Circuit Current 15 A Maximum Input Current 10 A OUTPUT(DC) DATA P250LV-240 Maximum Continuous Output Power 238 W Nominal Output Current 0.99 A Nominal Voltage 240 V Operating Voltage Range 211 V - 264 V Operating Frequency Range 59.3 Hz - 60.5 Hz Adjustable Frequency Range 57 Hz - 62.5 Hz Power Factor > 0.99 Total Harmonic Distortion IEEE 1547 Compliant Page 5 - 2 Data Sheet – Karra Model 2. Mechanical Characteristics Cells per Panel 60 Cells (6 x 10) Cell Type 156x156 mm Multi-crystalline Panel Dimension (L x W x H) 1,667 x 1,000 x 40 mm Panel Weight 18.5 Kg (without inverter / 2.3 Kg) Front Glass 3.2 mm Tempered Glass Back Sheet DuPont Tedlar film-based Junction Box Rated Current 14A / Rated Voltage 1000V(IEC) / IP65 Frame Anodized Aluminum Output cable (+,-) 600mm / 4 ㎟ cable Edge seal & J-box Sealant Dow Corning AC Inverter(Optional) SolarBridge P250LV-240 / 27.2 x 10.1 x 3.5 mm 3. Qualification Tests Temp cycling range -40℃ to 85℃ for 200cycles Damp heat test 85℃ and 85% relative humidity for 1000hr Front load test 2400 Pa (Snow) Rear static load test 5400 Pa (Wind) Hailstone impact test 25mm hail at 23m/s from 1m distance Page 5 - 3 Data Sheet – Karra Model 4. Safety ratings & Warranties Safety application class Class A Fire Safety Classification Class C Certifications Warranty Performance guarantee IEC 61215, IEC 61730 AC inverter - UL 1741 / CSA 107.1 / FCC Part 15 Class B 10 years limited product warranty 25 years limited warranty 80% power AC inverter - 25 years 5. Characteristics for System Design Temperature range Maximum system voltage -40℃ to 85℃ 1,000V DC(IEC) Maximum over-current protection 25 A 6. Monitor System ü Monitor each Karra panels individually at home or your smart phone. ü Safer for installer and system owners through elimination of dangerous high DC Voltage. ü Maximize each panel’s output to its full potential without it being affected by other panels in the array 7. Contact E-mail : [email protected] Phone : +61 1300 846 367 Website : www.tindosolar.com Address : 6 Second Ave Mawson Lakes SA 5095 Page 5 - 4 Data Sheet – Karra Model 8. Panel Drawing Page 5 - 5
© Copyright 2024 ExpyDoc