GVY40AA

GVY40AA
Product Data Sheet
OPERATION:
Application:
Refrigerant:
Operation:
Cooling:
L.B.P.
R134a
Capillary
Static
Max. Ambient Temp:
(1) Max. Steady Discharge Temp:
(1,2) Max. Peak Discharge Temp:
Max. Steady Condensing Temp:
(2) Max. Peak Condensing Temp:
Max. Winding Temp:
Max. Impurities:
Max.Total Compressor Water Content:
43°C
120°C
135°C
60°C
70°C
130°C
30 mg
100 mg
COMPRESSOR:
Displacement:
Bore:
Stroke:
(3) Net Wt:
Case Size:
Oil Charge:
3.87 cc
18.0 mm
15.2 mm
Oil Type:
(4) Viscosity:
Suction Muffler:
8.1 kg
2 (h = 169.5 mm)
160 cc
Ester
15 cSt
Semi-direct
h
ELECTRICAL:
Power Supply:
Voltage Limits:
Frequency:
Phase:
220 - 240V
187 - 264V
50 Hz
1 ph
Motor Type:
Locked Rotor Current:
Main Winding Resistance at 25°C:
Start Winding Resistance at 25°C:
*
RSIR / RSCR *
8.0 / 3.6 A**
21.2 Ω
26.2 Ω
With Optional Run Capacitor
** Maximum current / Measured after 4 seconds
For rated performance,
(1) Measured 5cm. from the shell with insulated thermocouples
the suction line must be connected to the stub
(2) For tr ansi ent condi ti ons dur i ng 'Pul l Down'
mar ked 'AS' on the attached dr awi ng.
(3) Net weight is with oil but without electrics
(4) Measured at 40°C
Feb '14
Secop reserves the right to change the data without prior notice
Page 1
GVY40AA
Product Data Sheet
ELECTRICAL COMPONENTS:
ECC Starting Device:
Starting Device:
(1) Starting Device:
PTC Resistance:
Run Capacitor:
K 100-xx
PTC- 8100
PTC - 7100D1
-xx Protector short code
14 Ω
3.0 µF
PROTECTORS:
BDG ¾
Electrica ¾
SENSATA ¾
SENSATA 4TM
Type
AE 18 FJ x
T 0602 / xx
MRP 334HZ xxxx
4TM 189 NFBYY xx
Open °C
110 - 120 °C
115 - 125 °C
115 - 125 °C
115 - 125 °C
Close °C
71 - 53 °C
70 - 52 °C
70 - 52 °C
70 - 52 °C
U.T.C
1.50 A 70 °C
1.32 A 70 °C
1.35 A 70 °C
1.35 A 70 °C
Time Check Current
6.35 A
4.50 A
4.40 A
5.6 A (5-15s)
Max. Current
14.0 A
10.0 A
12.0 A
12.2 A (2s max.)
Code (if any)
F8
C6
T5
69
Type
Open °C
Close °C
U.T.C
Time Check Current
Max. Current
Code (if any)
Alt. protectors:
Code (if any)
AF 18 FJ x
MSP 334HZ xxxx
D1
Sensata 'xxxx' Codes: 3201 for terminal boards Mod.89,90
BDG 'x' Codes: 6 for terminal boards Mod.89,90
3166 for ter mi nal boar d Mod.91
8 for ter mi nal boar d Mod.91
3178 for UH pr otector wi th 6.3mm fast-on
4 for UH pr otector wi th 6.3mm fast-on
3175 for UH pr otector wi th M3.5 scr ew
5 for UH pr otector wi th M3.5 scr ew
Electrica 'xx' Codes: 74 for terminal boards Mod.89,90
26 for terminal board Mod.91
24 for UH protector with M3.5 screw
25 for UH protector with 6.3mm fast-on
Sensata 4TM 'xx' Codes: .. for different contact versions
4TM protectors are for use with UH and ECC terminal boards only.
Protectors with M 3.5 screws can be used on UH electric housings type SP-1454 (with connection board)
and SP-1821 (without connection board).
See drawings ELECTRICAL ASSEMBLY (FOR UH) number FTC15;16;17;18.
¾ protectors with 6.3mm fast-on can only be used on UH electric housing type SP-1821 (without connection board).
Feb '14
Secop reserves the right to change the data without prior notice
Page 2
GVY40AA
Product Data Sheet
PERFORMANCE:
220V 50Hz Without run capacitor
(Graphs are at ASHRAE conditions)
0,74
Amps
0,70
60°C COND.
0,66
55°C TEMP.
0,62
50°C
45°C
0,58
40°C
0,54
0,50
125
Input
Watts 115
60°C COND.
105
55°C TEMP.
95
50°C
85
45°C
75
40°C
65
1,75
C.o.P.
1,65
40°C TEMP.
45°C TEMP.
1,55
50°C
1,45
55°C
1,35
60°C
1,25
1,15
1,05
0,95
215
Capacity
Watts200
40°C COND.
45°C TEMP.
185
50°C
170
55°C
60°C
155
140
125
110
Test Conditions:
Condensing Temp:
Liquid Temp:
Gas Return Temp:
Ambient Temp:
95
80
ASHRAE
55°C
32°C
32°C
32°C
CECOMAF
55°C
55°C
32°C
32°C
65
-35
-30
-25
-20
-15
Evaporating Temperature (°C)
-10
-5
Evaporating Temperature °C
-30
-25
-23,3
-20
-15
-10
ASHRAE:
Capacity
C.o.P.
W
W/W
69
0,99
97
1,18
107
1,24
129
1,36
166
1,54
207
1,71
CECOMAF:
Capacity
C.o.P.
W
W/W
66
0,81
79
0,96
105
1,11
136
1,26
168
1,39
W
A
69
0,51
82
0,55
95
0,59
108
0,64
121
0,70
Input Power
Current
Feb '14
86
0,56
Secop reserves the right to change the data without prior notice
Page 3
GVY40AA
Product Data Sheet
PERFORMANCE:
220V 50Hz With run capacitor
(Graphs are at ASHRAE conditions)
0,60
Amps
0,55
60°C COND.
0,50
55°C TEMP.
50°C
0,45
45°C
0,40
40°C
0,35
0,30
115
Input
Watts
60°C COND.
105
55°C TEMP.
95
50°C
45°C
85
40°C
75
65
1,90
C.o.P.
1,80
40°C COND.
1,70
45°C TEMP.
1,60
50°C
55°C
1,50
60°C
1,40
1,30
1,20
1,10
1,00
Capacity
WATTS
215
40°C COND.
200
45°C TEMP.
185
50°C
55°C
170
60°C
155
140
125
110
Test Conditions:
Condensing Temp:
Liquid Temp:
Gas Return Temp:
Ambient Temp:
95
80
ASHRAE
55°C
32°C
32°C
32°C
CECOMAF
55°C
55°C
32°C
32°C
65
-35
-30
-25
-20
-15
Evaporating Temperature (°C)
-10
-5
Evaporating Temperature °C
-30
-25
-23,3
-20
-15
-10
ASHRAE:
Capacity
C.o.P.
W
W/W
69
1,04
97
1,26
108
1,33
130
1,46
167
1,66
209
1,85
CECOMAF:
Capacity
C.o.P.
W
W/W
56
0,85
79
1,03
106
1,19
136
1,35
170
1,50
W
A
66
0,34
77
0,38
89
0,43
101
0,49
113
0,56
Input Power
Current
Feb '14
81
0,40
Secop reserves the right to change the data without prior notice
Page 4