Lithium Ion Battery Solutions Smart Solutions for a Green

Lithium Ion Battery Solutions
Activated By Samsung SDI
Smart Solutions for a Green World
www.acme.in
Value to customer
Technology
Leadership
• Proven & Mainstream Tech. as No.1 LIB Maker Globally
• Improvement on Energy Density with New Technology
Safety &
Quality
• Improved Material / Structure / Safety / Quality
High
Efficiency
• 95% or Higher
• Remote Monitoring Capability
Longer
cycle life
• Improved Cycle Life
• New Structure & Material
Cost
Effective
• Wide Supply Chain
• Highest possibility of cost reduction driven by xEV
Cell Cycle Life Analysis (DOD Vs. Cycle Vs. Temp)
0.3C Charge & Discharge Condition (SOC 100% means 4.0V/Cell)
Cycle life before battery performance reduces to 70% of the initial capacity
Cell Model
ICR1865022F
DOD
25℃
35℃
45℃
55℃
DOD 10%
15000
14700
14100
12750
DOD 30%
10000
9800
9400
8500
DOD 50%
6000
5880
5640
5100
DOD 70%
5000
4900
4700
4250
DOD 100%
4000
3800
3760
3400
* Cycle guarantee condition : Charging 4.0V, Cut-off 3.0V, Charging/Discharging 0.3C.
* Life of 10+ years considering 1 cycle per day
LIB has a wide operating temp
range than Lead-Acid :
Better Chemistry : NCM Vs. LFP
NCM Battery has longer calendar life
than LFP battery under the same
storage conditions.
From Li-Ion Cylindrical Cell to Battery Enclosure
Battery Enclosure
Benefits of LIB System(Summary) :
Item
Lead Acid
SDI Li-ion Battery
Remarks
Installation Space
100
60 (40% Less Space)

System Weight
100
30 (70% Less Weight)

Operation Temp. (Range for
Standard Performance)
20~20℃ (Need Cooling
System)
-10~55℃

Charging Rate
Low Charging Rate (10hrs)
Fast Charging Rate (1.5~3hrs)

Life Cycle (Range for Standard
Performance)
2~3 Yrs
10 Yrs (1 cycle per day)

ICR18650-22F Cylindrical Li-Ion Cell
Capacity
Nominal
44 Ah Battery Tray
Tray Specifications
2,200mAh
Nominal Voltage
3.60 V
Cell Configuration 14Series 20 Parallel
Charging Method
CC-CV
Width
442 mm
Charging Voltage
4.20 V
Depth
433 mm
Height
96 mm
Volume
18,373 ㎤
Weight
Approx. 21 kg
Li-ion Cell
ICR18650-22 Cylindrical
Capacity
2,217 Wh / 44 Ah
Nominal Voltage
50.4 VDC
Charging Current
Standard
1.10 A
Discharging Cut-off
Voltage
2.75 V
Discharging Current
Max
4.4 A
Weight
Max
42.5 g
Storage
Temperature
-20 ~ 25 ℃
-20 ~ 45 ℃
-20 ~ 60 ℃
-20 ~ 80 ℃
1 Year
3 Months
1 Months
3 Days
LiB ESS Solutions for Telecom Sites
11 - 16 Tray Systems 484 – 704 Ah
Configuration
5 - 10 Tray Systems 220 – 440 Ah
16 Tray System
10 Tray System
Nominal Voltage
5 Tray System
IP 43/54 Enclosure Dimension
[mm] suitable for outdoor
application
Battery Stack Dimension
[mm]
Mass (kg – excluding
enclosure)
Enclosure Weight (Kg)
176 AH
88 AH
56VDC
704AH
440 AH
220 AH
Operating temperature
Over Current Protection
2 Tray System
42V ~ 56VDC
Charge Voltage
Nominal Charge Current
4 Tray System
50.4VDC
Operation Voltage
Nominal Capacity
2 - 4 Tray Systems 88 – 176 Ah
-10 to 55 deg C
352A
220A
110A
88A
44A
720A
450A
225A
180A
90A
650Wx655Dx2100H
(Footprint area= 650 x
600 ) Max.
650Wx655Dx1500H
(Footprint area= 650 x 600) Max.
650Wx655Dx900H
Footprint area= 650 x 600) Max.
442x433x 1696
(WxDxH)
442x433x 1060
(WxDxH)
442x433x 530
(WxDxH)
442x433x 424
(WxDxH)
442x433x 212
(WxDxH)
Approx. 336kg
Approx. 210kg
Approx. 105kg
Approx. 84kg
Approx. 42kg
Approx. 200kg
Charging Method
Approx. 150kg
Approx. 110kg
CC-CV
Head Office : Plot No.: 152 Sector 44, Gurgaon-122002(Haryana) India
Ph. +91-124-7117000, Fax +91-124-7117001, Email : [email protected], Website : www.acme.in
Note: Specification are subject to change without prior intimation.