Power Supplies Catalogs > Industrial Controls Catalog > Power Supplies > Switched Mode SWITCHED MODE How to Select a Bulletin 1606 Power Quick Supply Guide Bulletin 1606 Special Module Specifications and Approximate Accessories Dimensions Introduction Certifications Product Selection Catalog Number Explanation Application Information Product Selection Build a Catalog Number 1606-XLS Performance — Single- and Three-Phase Single-Phase Input Voltage Output Output Output Input Power Voltage Current Circuit [W] [A] Protection∆ Steady State Input Current 120/230 [V AC] Parallel DC Cat. No. Operation OK Relay 100...240V AC, 110...300V DC 80 24…28 3.3 1.41/0.82 Yes — 1606-XLS80E 120 24…28 5 1.10/0.62 Yes 1606-XLS120E 120 24…28 5 1.10/0.62 Yes ★ 180 12…15 15 1.65/0.93 Yes 1606-XLS180B 240 24…28 10 2.22/1.22 Yes 1606-XLS240E 240 24…28 10 2.22/1.22 Yes ★ 1606-XLS240EA 240 24…28 10 2.22/1.22 Yes ◆ 1606-XLS240EC 6 A Slow Blow Fuse or Cat. No. 1489A1C060 6 A Slow Blow Fuse or Cat. No. 1489A1C060 1606-XLS120EA 240 48…56 5 2.22/1.22 Yes 1606-XLS240F 240 28…32 8 2.22/1.22 Yes 1606-XLS240K 480 24…28 20 4.56/2.48 Yes 1606-XLS480E 480 24…28 20 4.56/2.48 Yes ◆ 1606-XLS480EC 480 24...48 20 4.56/2.48 Yes ★ 1606-XLS480EA 200...240V AC 480 48…56 10 4.56/2.48 Yes 1606-XLS480F 100...240V AC, 110...300V DC 480 36…42 13.3 4.56/2.48 Yes 1606-XLS480G 200...240V AC, 220...300V DC 960 24…28 40 —/4.6 Yes 1606-XLS960EE 10 A Slow Blow Fuse or Cat. No. 1489A1C100 Three-Phase Input Voltage Output Output Output Input Steady Parallel DC Cat. No. Power Voltage Current Circuit State Operation OK [W] [A] Protection Input Relay Current 400...480 [V AC] 380…480V AC, 600V DC 480 24…28 20 380…480V AC, 600V DC 480 24…28 20 360…900V DC 480 24…28 20 380…480V AC, 600V DC 480 48…56 10 6 A Slow Blow Fuse or Cat. No. 1489A3C060 3 x 0.65 Yes 1606-XLS480E-3 Yes ◆ 3 x 0.85 Yes 1606-XLS480E-D 3 x 0.65 Yes 1606-XLS480F-3 1606-XLS480E-3C 380…480V AC, 600V DC 480 36…42 13.3 380…480V AC, 600V DC 960 24…28 40 380…480V AC, 600V DC 960 48...54 20 3 x 1.35 Yes 1606-XLS480G-3 Yes 1606-XLS960E-3 Yes 1606-XLS960F-3 ∆ Unit has internal (not accessible/replaceable) input fuse. Additional protection is not required if used on branch circuits UL test levels. Consult local codes and regulations for installation. ◆ The C suffix in the Cat. No. indicates that the product has conformal coating. ★ The A suffix in the Cat. No. indicates that the product carries the ATEX rating. 1606-XLE Essential — Single-Phase Input Voltage Output Output Output Input Power Voltage Current Circuit [W] [A] Protection Steady Parallel State Operation∇ Input Current 120/230 [V AC] DC Cat. No. OK Relay 100…120/200…240V AC 80 24…28 3.3 1.5/0.68 No — 1606-XLE80E 100…120/200…240V AC 120 24…28 5 2.34/1.23 No — 1606-XLE120E 100…120/200…240V AC 24…28 5 2.34/1.23 No — ◆ 90…132V AC 24…28 5 1.23/— No — 1606-XLE120EN 180…264V AC 24…28 5 —/1.17 No — 1606-XLE120EE 24…28 10 4.34/2.23 No — 1606-XLE240E 24…28 10 3.73/— Yes — 1606-XLE240EN 100…120/200…240V AC 90…132V AC 240 10 A Slow Blow Fuse or Cat. No. 1489A1C100/20∆ 1606-XLE120EC 180…264V AC 24…28 10 —/2.20 No — 1606-XLE240EE 100…120/200…240V AC 24…28 10 4.34/2.00 No — 1606-XLE240EP 100…120/200…240V AC 48…52 5 4.34/2.23 No — 1606-XLE240F 1606-XLE Essential — Three-Phase Input Voltage Output Output Output Input Power Voltage Current Circuit [W] [A] Protection Steady State Input Current 400...480 [V AC] Parallel Operation∇ DC Cat. No. OK Relay 380…480V AC, 600V DC 96 12...15 8 2 x 0.56 No — 380…480V AC, 600V DC 120 24…28 5 380…480V AC, 600V DC 240 24…28 380…480V AC, 600V DC 240 480V AC 480V AC 6 A Slow Blow Fuse or Cat. No. 1489A3C060 1606-XLE96B-2 3 x 0.60 1606-XLE120E-2 10 0.68 1606-XLE240E-3 48...56 5 3 x 0.60 1606-XLE240F-3 960 24 40 3 x 1.40 1606-XLE960DX-3N 960 48 20 3 x 1.40 1606-XLE960MX-3N 1606-XLP Compact — Single- and Two-Phase Single-Phase Input Voltage Output Output Output Input Steady Parallel DC Cat. No. 100…240V AC, 85…375V DC Power [W] Voltage Current Circuit State Operation OK [A] Protection Input Relay Current 120/230 [V AC] 15 5…5.5 3 12…15 1.3 24…28 0.6 25 5…5.5 5 0.60/0.30 30 10…12 3 0.60/0.25 24…28 1.3 0.60/0.35 10 A Slow Blow Fuse or Cat. No. 1489A1C100/ 15 A∆ 0.28/.017 Yes — 1606-XLP15A 0.28/.017 — 1606-XLP15B 0.28/.017 — 1606-XLP15E Yes — 1606-XLP25A Yes — 1606-XLP30B 1606-XLP30E 0.54/0.30 100…120/220…240V AC, 220…375V DC 100…200/200…240V AC, 220…375V DC Two-Phase — 1606-XLP30EQ 36 +/12/15V 2.8 0.65/0.40 No — 1606-XLP36C 50 12…15 4.2 1.00/0.60 Yes — 1606-XLP50B 24…28 2.1 0.77/0.44 Yes — 1606-XLP50E 24…28 2.1 1.00/0.60 Yes — 1606-XLP50EZ 48…56 1 1.00/0.60 Yes — 1606-XLP50F 54 12...15 4.5 0.91/0.54 Yes — 1606-XLP60BQ 54 12...15 4.5 0.97/0.61 Yes — 1606-XLP60BQT 60 24...48 2.1 0.98/0.58 Yes — 1606-XLP60EQ 60 24...48 2.1 1.05/0.66 Yes — 1606-XLP60EQT 72 24…28 3 1.60/0.80 Yes — 1606-XLP72E 90 12…15 7.5 1.90/0.90 Yes§ — 1606-XLP90B 95 24…28 3.9 2.00/0.95 No — 1606-XLP95E 100 24…28 4.2 2.10/1.00 Yes§ — 1606-XLP100E 48…56 2.1 2.10/1.00 Yes§ — 1606-XLP100F Input Voltage Output Power [W] Output Voltage Output Current [A] Input Circuit Protection Steady Parallel State Input Operation Current 400...480 [V AC] DC OK Relay Cat. No. 380…480V AC 90 24…28 3.75 2 x 0.36 No§ — 1606-XLP90E-2 380…480V AC 100 24…28 4.2 10 A Slow Blow Fuse or Cat. No. 1489A1C100 / 20 A∆ 2 x 0.40 Yes§ — 1606-XLP100E-2 ∆ Unit has internal (not accessible/replaceable) input fuse. Additional protection is not required if used on branch circuits UL test levels. § Single/parallel operation (inclined characteristic) selectable (jumper). Consult local codes and regulations for installation. Bulletin 1606 Back-of-Panel Brackets Instead of snapping the power supply onto a DIN Rail, you can mount it to the back of the panel. This set consists of two steel brackets which replace the existing DIN Rail aluminum brackets at the back of the unit. Note: You need one set per unit. Description Cat. No. Back-of-panel bracket for XLS and XLE power supplies, below 20 A 1606-XLB Back-of-panel bracket for XLS and XLE power supplies, 20 A and above 1606-XLC 1606 Special Modules Input Voltage Output Output Output Input Steady Power Voltage Current Circuit State [W] [A] Protection Input Current Parallel DC Cat. No. Operation OK Relay 120/230 [V AC] 18…36V DC 40 5.1 8 N/A N/A Yes — 1606-XLDC40A 14…32.4V DC 92 24 3.8 N/A N/A — — 1606-XLDC92D 100…240V AC, 110…300V DC 91 24 3.8 6 A SLOW BLOW FUSE OR 1489A1C060/20 A∆ 1.02/0.48 Yes 1606-XLSDNET4 100…240V AC, 110…300V DC 192 24 8 6 A SLOW BLOW FUSE OR 1489A1C060/20 A∆ 2.13/1.00 Yes 1606-XLSDNET8 100…120/200…240V AC 80 24…28 3.3 10 A SLOW BLOW FUSE OR 1489A1C100/20 A∆ 1.50/0.68 No — 1606-XLEDNET3 100…120/200…240V AC, 160…375V DC 60 24 2.5 10 A SLOW BLOW FUSE OR 1489A1C100/16 A∆ 1.30/0.70 Yes§ 1606-XL60DR 100…120/200…240V AC, 210…375V DC 120 5 10 A SLOW BLOW FUSE OR 1489A1C100/16 A∆ 2.60/1.40 Yes§ 1606-XL120DR 100…120/200…240V AC, 240…375V DC 240 10 10 A SLOW BLOW FUSE OR 1489A1C100/10 A∆ 6.00/2.60 Yes§ 1606-XL240DR 24V DC 720 Vin -.5V typ 30 N/A N/A‡ — — 1606-XLRED20-30 24V DC 960 Vin -.6V typ 40 N/A N/A♣ — — 1606-XLRED40 10…60V DC 384 Vin 1 -.9V typ 16◆ N/A N/A — — 1606-XLPRED 10…60V DC 480 Vin 1 -.9V 20◆ N/A N/A – – 1606-XLSRED typ 24...28 960 Vin 2.15 typ. 40 N/A N/A – – 1606-XLSRED40 24...28 1920 Vin 2.7 typ. 80 N/A N/A – – 1606-XLSRED80 24…60V DC 480 Vin 1 -.9V typ 20◆ N/A N/A – 1606-XLERED 1606 Special Modules with UPS Input Voltage Output Power [W] Output Voltage Output Current [A] Cat. No. 22.5…30V DC 240 22.5 10 ♠ 1606-XLS240-UPS 22.5…30V DC 240 22.5 10 1606-XLS240-UPSC 22.5...30V DC 240 12/22.5 5/10 1606-XLS240-UPSD 22.5...30V DC 240 22.5 10 1606-XLS240-UPSE 24…28.8V DC 480 22.5…27.8 20 1606-XLSBUFFER24 48…56V DC 960 45…54 10 1606-XLSBUFFER48 ‡ To be used alongside 20, 30, and 40 A power supplies. § Single/parallel operation (inclined characteristic) selectable (jumper). ♣ To be used alongside 40 A power supplies (or smaller). ∆ Unit has internal (not accessible/replaceable) input fuse. Additional protection is not required if used on branch circuits UL test levels. ◆ See product specifications for proper use. ♠ Cat. No. 1606-XLS240-UPS is a charging module, used along side a power supply and a battery assembly. The battery assembly must be ordered separately. Order Cat. No. 1606-XLSBATASSY1 for 7 Ah/ 12V battery assembly or Cat No. 1606-XLSBATASSY2 for 26 Ah/ 12V battery assembly. Consult local codes and regulations for installation.
© Copyright 2024 ExpyDoc