M10362 – FIGHTER 1330 with additional heat, hot water accumulators and exhaust air unit. Application Apartment buildings, industrial premises or similar with a large hot water demands. Oil boiler alt. electrical boiler with shunt valve Small electrical boiler with several steps District heating Function FIGHTER 1330 prioritises charging of hot water at full power (heat pump module A + B) via a 3-way valve (19). When the hot water accumulators (90) are fully charged, the shuttle valve (19) switches to the heating circuit. When there is a heat demand, one compressor starts first. For greater demands, the next compressor starts. FIGHTER 1330 connects the additional heat when the power demand exceeds the heat pump’s capacity. Flow line sensor (89) and return sensor (94) must be placed on the main line to and from the radiators. A by-pass contactor (31) is recommended. Additional heating HWC Note! This is an outline diagram. Actual installations must be planned according to applicable standards. See the appropriate “Installation and Maintenance Instructions” for more information. TIF GB 0925-3 PAGE 1 (2) NIBE AB Sweden- Box 14, Järnvägsgatan 40, SE-285 21 Markaryd Tel: +46-(0)433 - 73 000 Fax: +46-(0)433 - 73 190 E-mail: [email protected] www.nibe.com M10362 – FIGHTER 1330 with additional heat, hot water accumulators and exhaust air unit. List of Components Pos VP1 4 5 6 15 19 20 31 34 35 36 37 38 39 43 44 49 52 63 81 85 88 89 90 94 96 98 99 103 104 106 108 109 114 116 121 Name Heat pump Rock/Ground collector Pressure gauge Venting Outside temperature sensor (UG) Reversing valve (RV) Boiler sensor (PG) Auxiliary relay/Contactor with bypass Control box Circulation pump HWC-pump (VVC) Exchanger, hot water Charge pump, hot water (VVL) Control valve, hot water Shunt valve (SV-P) Shut-off valve Non-return valve Safety valve Particle filter Control valve Expansion vessel Hot water sensor (HWS) Flow line sensor (FG) Hot water accumulator Return sensor (RG) Water heater Oil boiler Electric boiler Heating medium pump (VBP3) Expansion card 11 Mixing vessel Hot water charge sensor, regulator (VVLG) Circulation pump, boiler Exhaust air unit Remote heat exchanger HWC valve TIF GB 0925-3 PAGE 2 (2) Specification FIGHTER 1330 Manufacturer NIBE HR 10 A60DA, 230/24V NIBE NIBE NIBE NIBE Siemens HVAC Products PLEX 322 -60 UPS 32-80B VVG41.25-10, SQX62 NIBE Grundfos Siemens HVAC Products VST 20 Part No. 089388 Hot water circulation Max 40 kW charge power Included in FIGHTER 1330 With req. safety equipment Included in FIGHTER 1330 Included in FIGHTER 1330 NIBE NIBE NIBE NIBE NIBE EXP 11 (for HWC) NIBE RLE 162 Siemens Included in FIGHTER 1330 VST 20 max 40 kW charge power Included in FIGHTER 1330 089423 NIBE AKIL 500 Remarks Master Included in FIGHTER 1330 067042 NIBE AB Sweden- Box 14, Järnvägsgatan 40, SE-285 21 Markaryd Tel: +46-(0)433 - 73 000 Fax: +46-(0)433 - 73 190 E-mail: [email protected] www.nibe.com Accessories FIGHTER 1330
© Copyright 2025 ExpyDoc