1 2 3 4 115 115 6 7 8 RB LD+200 9 1 5 460 X ( 1 : 10 ) 115 6 A A 100 FFL 40...50 Y Z 400 X B 2300 outside 2 1000 3 6 1288 4 10 1000 8 inside B, C, E B, C 1000 10 2144 C A, D B 1. Tracked Gate M50 with shallow foundation, crash test certified according to ASTM F 2656-07 M50/P1 (tested with 7 m Clear Width of Opening) operating speed 0.4 m/sec 2. guiding portal incl. posts SHS 260 x 260 containing: 4 nos. light beams (transmitter or receiver) 2 nos. key switches "open-close-stop" 3. receiving portal incl. posts SHS 260 x 260 containing: 4 nos. light beams (transmitter or receiver) 4. drive unit 1.5 kW, 400 V (three-phase), 50 Hz control unit WE-tronic II, frequency converter 5. ground track S10 to bolt on 6. safety edges 7. optional: push button "open-stop-close" 8. foundation with reinforcement, concrete min. C20/25 6 3000 5 2000 A 1000 B 3000 500 1055 100 100 140 TH+162 TH+100 6 10 Z ( 1 : 10 ) C 9. finger guard - Makrolon 6 mm 10. flexible conduit pipes DN25 ... DN50 6 1 Gate leaf and portals: RAL 6005 RAL 7016 RAL 7030 RAL 7035 RAL 9010 RAL ____ o260 D Y ( 1 : 10 ) Drive cabinet: Standard RAL 7035 in RAL colour of gate special: __________ D Access control equipment: _________ _________ _________ _________ _________ Anti-climbing device: without serrated top rail steel spikes ∅18, 100 mm long barbed wire holder ___mm long with __ rows of barbed wire E Emergency Fast Operation/EFO: without with EFO, gate speed up to 0.8 m/s (only available for non-European countries E Cable details: F RB 5308 6308 7308 8308 9308 A 1460 2460 3460 4460 5460 B 3600 4400 5200 5900 6700 TH 2000 2500 3000 Weitergabe sowie Vervielfältigung dieses Dokuments, Verwertung und Mitteilung seines Inhalts sind verboten, soweit nicht ausdrücklich gestattet. Zuwiderhandlungen verpflichten zu Schadenersatz. Alle Rechte für den Fall der Patent-, Gebrauchsmuster- oder Geschmacksmustereintragung vorbehalten. 1 2 3 4 20 The reproduction, distribution and utilization of this document as well as the communication of its contents to others without explicit authorization is prohibited.Offenders will be held liable for the payment of damages. All rights reserved in the event of the grant of a patent, utility model or design. 5 Schutzvermerk nach ISO16016 beachten. Copyright reserved. LD 3,00 m 4,00 m 5,00 m 6,00 m 7,00 m 100 100 FFL A B; C D E mains supply control line NYY-J 5x2.5 mm² A-2YF(L) 2Y 4x2x0.8mm² control line A-2YF(L) 2Y 4x2x0.8mm² weight material surface treatment 27700.142 kg last change: network-control board light beams, safety edges optional controller key switch pulverbeschichtet Tracked Gate M50 righthand opening ASTM general tolerances acc. DIN ISO 2768-mK surface date 08.02.2016 name Reinke design 08.02.2016 Reinke replaces origin part-No. format DIN A2 dwg.-No. 2093974 2093973.iam 1:50 mm ISO 1302 draft scale dim. unit Salzkotten, Germany Z-2093974 Version FS Index 3 revision F
© Copyright 2024 ExpyDoc