STD DRAW TG M50 ASTM_right hand_EN

1
2
3
4
115
115
6
7
8
RB
LD+200
9
1
5
460
X ( 1 : 10 )
115
6
A
A
100
FFL
40...50
Y
Z
400
X
B
2300
outside
2
1000
3
6
1288
4
10
1000
8
inside
B, C, E
B, C
1000
10
2144
C
A, D
B
1.
Tracked Gate M50 with shallow foundation, crash test certified according to
ASTM F 2656-07 M50/P1 (tested with 7 m Clear Width of Opening)
operating speed 0.4 m/sec
2.
guiding portal incl. posts SHS 260 x 260
containing:
4 nos. light beams (transmitter or receiver)
2 nos. key switches "open-close-stop"
3.
receiving portal incl. posts SHS 260 x 260
containing:
4 nos. light beams (transmitter or receiver)
4.
drive unit 1.5 kW, 400 V (three-phase), 50 Hz
control unit WE-tronic II, frequency converter
5.
ground track S10 to bolt on
6.
safety edges
7.
optional: push button "open-stop-close"
8.
foundation with reinforcement, concrete min. C20/25
6
3000
5
2000
A
1000
B
3000
500
1055
100
100
140
TH+162
TH+100
6
10
Z ( 1 : 10 )
C
9.
finger guard - Makrolon 6 mm
10.
flexible conduit pipes DN25 ... DN50
6
1
Gate leaf and portals:
RAL 6005
RAL 7016
RAL 7030
RAL 7035
RAL 9010
RAL ____
o260
D
Y ( 1 : 10 )
Drive cabinet:
Standard RAL 7035
in RAL colour of gate
special: __________
D
Access control equipment:
_________
_________
_________
_________
_________
Anti-climbing device:
without
serrated top rail
steel spikes ∅18, 100 mm long
barbed wire holder ___mm long
with __ rows of barbed wire
E
Emergency Fast Operation/EFO:
without
with EFO, gate speed up to 0.8 m/s
(only available for non-European countries
E
Cable details:
F
RB
5308
6308
7308
8308
9308
A
1460
2460
3460
4460
5460
B
3600
4400
5200
5900
6700
TH
2000
2500
3000
Weitergabe sowie Vervielfältigung dieses Dokuments, Verwertung und Mitteilung
seines Inhalts sind verboten, soweit nicht ausdrücklich gestattet. Zuwiderhandlungen
verpflichten zu Schadenersatz. Alle Rechte für den Fall der Patent-,
Gebrauchsmuster- oder Geschmacksmustereintragung vorbehalten.
1
2
3
4
20
The reproduction, distribution and utilization of this document as well as the
communication of its contents to others without explicit authorization is
prohibited.Offenders will be held liable for the payment of damages. All rights
reserved in the event of the grant of a patent, utility model or design.
5
Schutzvermerk nach ISO16016 beachten.
Copyright reserved.
LD
3,00 m
4,00 m
5,00 m
6,00 m
7,00 m
100 100
FFL
A
B; C
D
E
mains supply
control line
NYY-J 5x2.5 mm²
A-2YF(L) 2Y 4x2x0.8mm²
control line
A-2YF(L) 2Y 4x2x0.8mm²
weight
material
surface treatment
27700.142 kg
last change:
network-control board
light beams, safety edges
optional controller
key switch
pulverbeschichtet
Tracked Gate M50
righthand opening
ASTM
general tolerances acc.
DIN ISO 2768-mK
surface
date
08.02.2016
name
Reinke
design 08.02.2016
Reinke
replaces
origin
part-No.
format
DIN A2
dwg.-No.
2093974
2093973.iam
1:50
mm
ISO 1302
draft
scale
dim. unit
Salzkotten, Germany
Z-2093974
Version FS Index 3
revision
F