Who is who

Who is who
INFO
Straumann ® Dental Implant System
w w w. s t r a u m a n n . c o m
Straumann® Dental Implant System
Ø 3.3 mm
System Overview
Standard Plus
Standard
NN
SURGERY
Implants
Standard Plus
RN
Tapered Effect
RN
RN
Ø 3.5 mm
Ø 4.8 mm
Ø 4.8 mm
Ø 4.8 mm
Ø 4.8 mm
Ø 3.3 mm
Ø 3.3 mm
Ø 3.3 mm
Ø 3.3 mm
Ø 4.1 mm
Standard Plus
RN
Standard
Standard
Standard Plus
Tapered Effect
Standard
–
–
–
–
6.0 mm
043.030S
042.930S
043.131S
043.151S
043.721S
8.0 mm
043.031S
042.931S
043.132S
043.152S
043.722S
10.0 mm
043.032S
042.932S
043.133S
043.153S
043.723S
12.0 mm
043.033S
042.933S
043.134S
043.154S
043.724S
14.0 mm
043.034S
–
043.135S
–
–
16.0 mm
043.035S
SLA®
Drills
Round bur
Round bur
Round bur
Round bur
Ø 1.4 mm
044.022
Ø 2.3 mm
044.003
Ø 3.1 mm
044.004
Ø 1.4 mm
044.022
Pilot drill 1
Pilot drill 2
Pilot drill 1
Ø 2.2 mm
044.210 short
044.211 long
Ø 2.8 mm
044.214 short
044.215 long
Ø 2.2 mm
044.210 short
044.211 long
Profile drills
SP Profile drill
044.086 short
044.087 long
TE Profile drill
044.701 short
044.708 long
Alignment pin
Ø 2.2 mm
046.458
Depth gauges
Ø 2.2/2.8 mm
046.455
Taps
Ø 3.3 mm
044.590 short
044.591 long
Ø 4.1 mm
044.592 short
044.593 long
Adapter tap
044.575
Healing caps, closure screws
and protective caps
048.043
048.374
048.371
048.050
NN = Narrow Neck
048.373
048.028
RN = Regular Neck
WN = Wide Neck
SP = Standard Plus
TE = Tapered Effect
xxx.xxxS = Sterile
Straumann® Dental Implant System
System Overview
NN (Narrow Neck)
RN (Regular Neck)
WN (Wide Neck)
Ø 3.5 mm
Ø 4.8 mm
Ø 6.5 mm
PROSTHETICS
synOcta®
Transfer parts
Solid
048.017V4
048.016
048.090
048.010
048.013
048.014
screw-retained
or cemented
screw-retained
048.197V4
048.160/161/162
048.117V4
048.109
cemented
Retentive
anchor
screw-retained
or cemented
cemented
cemented
048.926/927/928V4
048.121
steco®
TITANMAGNETICS®
048.013
048.198V4
LOCATOR®
048.013
048.065/066
048.091
048.070V4
048.124
048.130
Prosthetic restoration
048.017V4
Solid
048.017V4
048.060/061/062V4
048.122V4
synOcta®
Hybrid
048.095
048.165/166
048.171
screw-retained
cemented
048.140
cemented
Case planning
(V4 only)
048.935V4
048.936V4
048.937V4
048.920V4
048.929V4
048.921V4
ͷ/ͷͷ 048.916/917/918/919V4
048.930V4
048.600
048.602
048.620
ͷ/ͷͷ 048.612/613/617/618
048.605
048.931V4
048.933V4
048.934V4
048.932V4
048.603
048.608
048.609
048.606
Abutments
048.540
048.541
048.542
048.439
048.511
048.175 –
048.180
048.545
048.546
048.656••/657•
048.051/052
•• 048.248
•048.247
Temporary restorations/
Protective caps
048.050
• 048.651
•• 048.650
048.654••/655•
048.047/048/049V4
• 048.233
•• 048.234
Copings titanium
048.505
048.550
048.551
••• 048.214
•• /241
• /240
• /571
048.450
048.515
048.189V2
• 048.573
Coping ceramic
048.680
Copings gold
048.500
048.635
••• 048.204
•• 048.632
• 048.633
••/••• 048.227
• 048.229
048.665
048.360V4
048.361V4
049.154 048.672
048.350
048.003V4
048.000V4
• 048.642
048.634
048.456
•• 048.638
• 048.639
•• 048.666
• 048.667
048.350
048.361V4
Copings plastic
048.676V4
048.670
••
•
048.662 048.663
•• 048.246
•048.245
048.678
•
••
048.244 048.243
048.032
048.054V4
Auxiliary parts/Screws
049.177
048.350
048.516
Transfer aids
• crown
001-002_Prothetik_cart.indd Abs1:1-Abs1:3
•• bridge
••• bar
ͷ not for hollow cylinder implants, 15 °
ͷͷ the long RN synOcta® angled abutments (048.610/048.611/048.615/048.616) are still available
048.059V4
V4 = 4 components per pack
18.03.2005 9:49:26 Uhr
Ø 4.1 mm
Standard Plus
Ø 4.8 mm
Tapered Effect
Standard
Standard Plus
Standard
Standard Plus
WN
Tapered Effect
RN
RN
RN
RN
Ø 4.8 mm
Ø 4.8 mm
Ø 4.8 mm
Ø 4.8 mm
Ø 6.5 mm
Ø 6.5 mm
WN
Ø 6.5 mm
WN
Ø 4.1 mm
Ø 4.1 mm
Ø 4.8 mm
Ø 4.8 mm
Ø 4.8 mm
Ø 4.8 mm
Ø 4.8 mm
Standard Plus
Tapered Effect
Standard
Standard Plus
Standard
Standard Plus
Tapered Effect
–
043.050S
–
6.0 mm
043.230S
043.250S
043.630S
043.650S
043.051S
043.761S
8.0 mm
043.231S
043.251S
043.631S
043.651S
–
043.052S
043.762S
10.0 mm
043.232S
043.252S
043.632S
043.652S
043.712S
043.053S
043.763S
12.0 mm
043.233S
043.253S
043.633S
043.653S
043.713S
043.054S
043.764S
14.0 mm
043.234S
043.254S
–
–
043.714S
–
–
16.0 mm
–
–
–
–
–
SLA®
Round bur
Round bur
Round bur
Round bur
Round bur
Ø 2.3 mm
044.003
Ø 3.1 mm
044.004
Ø 1.4 mm
044.022
Ø 2.3 mm
044.003
Ø 3.1 mm
044.004
Pilot drill 2
Twist drill
Pilot drill 1
Pilot drill 2
Twist drill
Twist drill
Ø 2.8 mm
044.214 short
044.215 long
Ø 3.5 mm
044.218 short
044.219 long
Ø 2.2 mm
044.210 short
044.211 long
Ø 2.8 mm
044.214 short
044.215 long
Ø 3.5 mm
044.218 short
044.219 long
Ø 4.2 mm
044.222 short
044.223 long
SP Profile drill
044.088 short
044.089 long
TE Profile drill
044.705 short
044.712 long
SP Profile drill
044.084 short
044.085 long
Ø 2.2 mm
046.458
Ø 2.2 mm
046.458
Ø 3.5 mm
046.450
Ø 4.2 mm
046.451
Ø 4.8 mm
044.594 short
044.595 long
Adapter tap
044.577
048.033
048.034
048.037
048.029
TE Profile drill
044.703 short
044.710 long
Adapter tap
044.579
048.375
048.038
048.039
048.053
048.030
SLA® = Sand-blasted, Large grit, Acid-etched
001-002_Prothetik_cart.indd Abs1:4-Abs1:6
18.03.2005 9:49:48 Uhr
Important Notes
Disclaimer of liability
The Straumann dental implant is part of an overall concept and
may only be used in conjunction with the associated original
components and instruments according to Institut Straumann AG’s
instructions and recommendations.
Explanation of the symbols on labels and instruction leaflets
Lot/batch number
Article number
Use of products made by third parties in conjunction with the
Straumann® Dental Implant System will void any warranty or other
obligation, express or implied, of Institut Straumann AG.
Instructions as to application of our products take place verbally, in
writing, by electronic media or in hands-on trainings corresponding to
state of the art at the time of introduction of the product.
The user of Straumann products has the duty to determine whethe or
not any product is suitable for the particular patient and circumstances.
Straumann disclaims any liability, express or implied, and shall have
no responsibility for any direct, indirect, punitive or other damages,
arising out of or in connection with any errors in professional judgment
or practice in the use or installation of Straumann products.
The user is also obliged to study the latest developments of the
Straumann® Dental Implant System and their applications
regularly.
Sterile by gamma irradiation
Nonsterile
Lower limit of temperature
…min.
…max.
Upper temperature limit
…max.
Temperature limitation
…min.
Please note
The descriptions given are insufficient to allow immediate use of
the Straumann® Dental Implant System. Guidance in the handling of
these instruments by a doctor experienced in their use is strongly
recommended.
Caution: Federal (USA) law restricts this
product to sale by or on the order of a
dentist or physician.
Availability
Not all products listed in this brochure are available in all countries.
Do not use on patients
Validity
Upon publication of this brochure, all previous versions are superseded.
Do not reuse
Caution
As a general rule, our products must be secured against aspiration
when used intra-orally.
Refer to instructions for use
Use before expiry date
Delivery
Federal law restricts these devices to sale by or on the order of a
dentist or a physician.
Protect from exposure to strong light or heat
Units per package
Unless stated otherwise, there is one unit in each package.
Documentation
You can obtain detailed instructions on the Straumann® Dental Implant
System from your Straumann representative.
Copyright and trademarks
Straumann documents may not be reprinted or published, in whole
or part, without the written authorization of Institut Straumann AG.
Straumann® Dental Implant System, synOcta® and SLA® are registered
trademarks of Institut Straumann AG, Switzerland.
XXXX
Straumann products carry the CE mark and
fulfill the requirements of the Medical Devices
Directive 93/42 EEC.
Colored warning labels
YELLOW = CAUTION:
indicates hazards or unsafe handling
which might cause minor injury or
damage to property.
ORANGE = WARNING:
indicates hazards which might cause
serious or fatal injury.
RED = DANGER:
indicates hazards which might cause
immediate serious or fatal injury.
Definition SLA®
Sand-blasted, Large grit, Acid-etched
National Distributor
International Headquarters
Institut Straumann AG
Peter Merian-Weg 12
Postfach
CH-4002 Basel
Switzerland
Phone +41 (0) 61 965 11 11
Fax +41 (0) 61 965 11 01
www.straumann.com
Straumann products are CE marked
03/05 152.250/e
C00305