Who is who INFO Straumann ® Dental Implant System w w w. s t r a u m a n n . c o m Straumann® Dental Implant System Ø 3.3 mm System Overview Standard Plus Standard NN SURGERY Implants Standard Plus RN Tapered Effect RN RN Ø 3.5 mm Ø 4.8 mm Ø 4.8 mm Ø 4.8 mm Ø 4.8 mm Ø 3.3 mm Ø 3.3 mm Ø 3.3 mm Ø 3.3 mm Ø 4.1 mm Standard Plus RN Standard Standard Standard Plus Tapered Effect Standard – – – – 6.0 mm 043.030S 042.930S 043.131S 043.151S 043.721S 8.0 mm 043.031S 042.931S 043.132S 043.152S 043.722S 10.0 mm 043.032S 042.932S 043.133S 043.153S 043.723S 12.0 mm 043.033S 042.933S 043.134S 043.154S 043.724S 14.0 mm 043.034S – 043.135S – – 16.0 mm 043.035S SLA® Drills Round bur Round bur Round bur Round bur Ø 1.4 mm 044.022 Ø 2.3 mm 044.003 Ø 3.1 mm 044.004 Ø 1.4 mm 044.022 Pilot drill 1 Pilot drill 2 Pilot drill 1 Ø 2.2 mm 044.210 short 044.211 long Ø 2.8 mm 044.214 short 044.215 long Ø 2.2 mm 044.210 short 044.211 long Profile drills SP Profile drill 044.086 short 044.087 long TE Profile drill 044.701 short 044.708 long Alignment pin Ø 2.2 mm 046.458 Depth gauges Ø 2.2/2.8 mm 046.455 Taps Ø 3.3 mm 044.590 short 044.591 long Ø 4.1 mm 044.592 short 044.593 long Adapter tap 044.575 Healing caps, closure screws and protective caps 048.043 048.374 048.371 048.050 NN = Narrow Neck 048.373 048.028 RN = Regular Neck WN = Wide Neck SP = Standard Plus TE = Tapered Effect xxx.xxxS = Sterile Straumann® Dental Implant System System Overview NN (Narrow Neck) RN (Regular Neck) WN (Wide Neck) Ø 3.5 mm Ø 4.8 mm Ø 6.5 mm PROSTHETICS synOcta® Transfer parts Solid 048.017V4 048.016 048.090 048.010 048.013 048.014 screw-retained or cemented screw-retained 048.197V4 048.160/161/162 048.117V4 048.109 cemented Retentive anchor screw-retained or cemented cemented cemented 048.926/927/928V4 048.121 steco® TITANMAGNETICS® 048.013 048.198V4 LOCATOR® 048.013 048.065/066 048.091 048.070V4 048.124 048.130 Prosthetic restoration 048.017V4 Solid 048.017V4 048.060/061/062V4 048.122V4 synOcta® Hybrid 048.095 048.165/166 048.171 screw-retained cemented 048.140 cemented Case planning (V4 only) 048.935V4 048.936V4 048.937V4 048.920V4 048.929V4 048.921V4 ͷ/ͷͷ 048.916/917/918/919V4 048.930V4 048.600 048.602 048.620 ͷ/ͷͷ 048.612/613/617/618 048.605 048.931V4 048.933V4 048.934V4 048.932V4 048.603 048.608 048.609 048.606 Abutments 048.540 048.541 048.542 048.439 048.511 048.175 – 048.180 048.545 048.546 048.656••/657• 048.051/052 •• 048.248 •048.247 Temporary restorations/ Protective caps 048.050 • 048.651 •• 048.650 048.654••/655• 048.047/048/049V4 • 048.233 •• 048.234 Copings titanium 048.505 048.550 048.551 ••• 048.214 •• /241 • /240 • /571 048.450 048.515 048.189V2 • 048.573 Coping ceramic 048.680 Copings gold 048.500 048.635 ••• 048.204 •• 048.632 • 048.633 ••/••• 048.227 • 048.229 048.665 048.360V4 048.361V4 049.154 048.672 048.350 048.003V4 048.000V4 • 048.642 048.634 048.456 •• 048.638 • 048.639 •• 048.666 • 048.667 048.350 048.361V4 Copings plastic 048.676V4 048.670 •• • 048.662 048.663 •• 048.246 •048.245 048.678 • •• 048.244 048.243 048.032 048.054V4 Auxiliary parts/Screws 049.177 048.350 048.516 Transfer aids • crown 001-002_Prothetik_cart.indd Abs1:1-Abs1:3 •• bridge ••• bar ͷ not for hollow cylinder implants, 15 ° ͷͷ the long RN synOcta® angled abutments (048.610/048.611/048.615/048.616) are still available 048.059V4 V4 = 4 components per pack 18.03.2005 9:49:26 Uhr Ø 4.1 mm Standard Plus Ø 4.8 mm Tapered Effect Standard Standard Plus Standard Standard Plus WN Tapered Effect RN RN RN RN Ø 4.8 mm Ø 4.8 mm Ø 4.8 mm Ø 4.8 mm Ø 6.5 mm Ø 6.5 mm WN Ø 6.5 mm WN Ø 4.1 mm Ø 4.1 mm Ø 4.8 mm Ø 4.8 mm Ø 4.8 mm Ø 4.8 mm Ø 4.8 mm Standard Plus Tapered Effect Standard Standard Plus Standard Standard Plus Tapered Effect – 043.050S – 6.0 mm 043.230S 043.250S 043.630S 043.650S 043.051S 043.761S 8.0 mm 043.231S 043.251S 043.631S 043.651S – 043.052S 043.762S 10.0 mm 043.232S 043.252S 043.632S 043.652S 043.712S 043.053S 043.763S 12.0 mm 043.233S 043.253S 043.633S 043.653S 043.713S 043.054S 043.764S 14.0 mm 043.234S 043.254S – – 043.714S – – 16.0 mm – – – – – SLA® Round bur Round bur Round bur Round bur Round bur Ø 2.3 mm 044.003 Ø 3.1 mm 044.004 Ø 1.4 mm 044.022 Ø 2.3 mm 044.003 Ø 3.1 mm 044.004 Pilot drill 2 Twist drill Pilot drill 1 Pilot drill 2 Twist drill Twist drill Ø 2.8 mm 044.214 short 044.215 long Ø 3.5 mm 044.218 short 044.219 long Ø 2.2 mm 044.210 short 044.211 long Ø 2.8 mm 044.214 short 044.215 long Ø 3.5 mm 044.218 short 044.219 long Ø 4.2 mm 044.222 short 044.223 long SP Profile drill 044.088 short 044.089 long TE Profile drill 044.705 short 044.712 long SP Profile drill 044.084 short 044.085 long Ø 2.2 mm 046.458 Ø 2.2 mm 046.458 Ø 3.5 mm 046.450 Ø 4.2 mm 046.451 Ø 4.8 mm 044.594 short 044.595 long Adapter tap 044.577 048.033 048.034 048.037 048.029 TE Profile drill 044.703 short 044.710 long Adapter tap 044.579 048.375 048.038 048.039 048.053 048.030 SLA® = Sand-blasted, Large grit, Acid-etched 001-002_Prothetik_cart.indd Abs1:4-Abs1:6 18.03.2005 9:49:48 Uhr Important Notes Disclaimer of liability The Straumann dental implant is part of an overall concept and may only be used in conjunction with the associated original components and instruments according to Institut Straumann AG’s instructions and recommendations. Explanation of the symbols on labels and instruction leaflets Lot/batch number Article number Use of products made by third parties in conjunction with the Straumann® Dental Implant System will void any warranty or other obligation, express or implied, of Institut Straumann AG. Instructions as to application of our products take place verbally, in writing, by electronic media or in hands-on trainings corresponding to state of the art at the time of introduction of the product. The user of Straumann products has the duty to determine whethe or not any product is suitable for the particular patient and circumstances. Straumann disclaims any liability, express or implied, and shall have no responsibility for any direct, indirect, punitive or other damages, arising out of or in connection with any errors in professional judgment or practice in the use or installation of Straumann products. The user is also obliged to study the latest developments of the Straumann® Dental Implant System and their applications regularly. Sterile by gamma irradiation Nonsterile Lower limit of temperature …min. …max. Upper temperature limit …max. Temperature limitation …min. Please note The descriptions given are insufficient to allow immediate use of the Straumann® Dental Implant System. Guidance in the handling of these instruments by a doctor experienced in their use is strongly recommended. Caution: Federal (USA) law restricts this product to sale by or on the order of a dentist or physician. Availability Not all products listed in this brochure are available in all countries. Do not use on patients Validity Upon publication of this brochure, all previous versions are superseded. Do not reuse Caution As a general rule, our products must be secured against aspiration when used intra-orally. Refer to instructions for use Use before expiry date Delivery Federal law restricts these devices to sale by or on the order of a dentist or a physician. Protect from exposure to strong light or heat Units per package Unless stated otherwise, there is one unit in each package. Documentation You can obtain detailed instructions on the Straumann® Dental Implant System from your Straumann representative. Copyright and trademarks Straumann documents may not be reprinted or published, in whole or part, without the written authorization of Institut Straumann AG. Straumann® Dental Implant System, synOcta® and SLA® are registered trademarks of Institut Straumann AG, Switzerland. XXXX Straumann products carry the CE mark and fulfill the requirements of the Medical Devices Directive 93/42 EEC. Colored warning labels YELLOW = CAUTION: indicates hazards or unsafe handling which might cause minor injury or damage to property. ORANGE = WARNING: indicates hazards which might cause serious or fatal injury. RED = DANGER: indicates hazards which might cause immediate serious or fatal injury. Definition SLA® Sand-blasted, Large grit, Acid-etched National Distributor International Headquarters Institut Straumann AG Peter Merian-Weg 12 Postfach CH-4002 Basel Switzerland Phone +41 (0) 61 965 11 11 Fax +41 (0) 61 965 11 01 www.straumann.com Straumann products are CE marked 03/05 152.250/e C00305
© Copyright 2024 ExpyDoc