FM – PVC – supported Mid rise - travelling height maximum 150m Drawing according to article number 177690 - Type 8666-F BESCHREIBUNG Elevator suspension cable for indoor and panoramic elevators. ANWENDUNG To comply with the correct installation procedures please refer to the Datwyler installation manual which is available separately. KONSTRUKTION Core flexible: Core insulation: Data elements: Supporting members: ST = Steel, diameter in [mm] Outer sheath: class 5 PVC details according to page 36/37 HTF = High tensile fibre, PVC MECHANISCHE EIGENSCHAFTEN Free suspension length: Travelling height: Running speed: Acceleration: Operating temperature: Recommended loop diameter: maximum 80 m maximum 150 m maximum 6.3 m/s < 1.2 m/s2 -15 to +70 °C according to table, tolerance -50/+100 mm FARBCODE Core: G = with green-yellow core(s) Pair/quad: various colours or black with white numbers Coax: black, white numbered, grey EIGENSCHAFTEN Rated voltage Uo/U: Stand 11.07.2016 according to table Technische Änderungen vorbehalten. FM – PVC – supported Mid rise - travelling height maximum 150m NORMEN Anwendbare Normen Mantelfarbe EN 50214 grau VERSIONEN Artikel Nummer Produkt CuSuspension Loop Zahl device [mm] [kg/km] Normen Supporting members Cross sectional area Rated Gewicht voltage [V] [kg/100m] Datenelemente Overall dimensions [mm x mm] 165342 6599-F 144 LZ 1009 300 EN 50214 HTF 20 G 0.75 300/500 46.5 none 62.8 x 4.3 165344 6599-F 173 LZ 1009 300 EN 50214 HTF 24 G 0.75 300/500 54.9 none 73.1 x 4.3 156879 7770-F 173 LZ 1009 400 EN 50214 ST Ø 2.5 24 G 0.75 300/500 59.0 none 73.2 x 4.3 166618 6599-F 173 LZ 1009 300 EN 50214 HTF 18 G 1.00 300/500 47.3 none 58.6 x 4.4 166505 6599-F 230 LZ 1009 300 EN 50214 HTF 24 G 1.00 300/500 63.0 none 75.4 x 4.4 155425 7757-F 187 LZ 1009 450 EN 50214 ST Ø 2.5 4 + + + 300/500 300/500 250/250 250/250 65.9 G 1.00 16 x 0.75 2 x 4 x 0.25 1 x 2 x 0.25 7067/2-F 7954/2-F 176877 6900-F 173 LZ 1006 400 EN 50214 HTF 6 G 1.50 450/750 + 6 x 1.00 300/500 + 1 x 4 x 0.50 300/300 59.6 166612 7500-F 139 LZ 1006 400 EN 50214 HTF 12 G 1.00 300/500 + 1 x CX 75 Ω 53.0 EN 50214 HTF 12 G 1.00 300/500 + 1 x 4 x 0.34 300/300 52.5 EN 50214 ST Ø 2.5 4 + + + 450/750 300/500 300/300 300/300 84.3 4 G 1.50 450/750 + 16 x 1.00 300/500 + 3 x 2 x 0.50 300/500 89.6 2 x 1.50 450/750 + 1 x CX 75 Ω + 8 x 2 x 0.50 300/300 58.0 4 x 1.50 450/750 + 2 x CX 75 Ω + 8 x 2 x 0.50 300/300 71.6 4 x 1.50 450/750 + 2 x CX 75 Ω + 8 x 2 x 0.50 300/300 74.5 4 x 1.50 450/750 + 4 x CX 75 Ω + 8 x 2 x 0.50 300/300 82.5 177690 167088 168190 167018 168191 182058 185217 8666-F 7757-F 8483-F 8210-F 8210-F 8820-F 185217 142 250 275 149 201 201 249 LZ 1006 LZ 1009 LZ 1010 LZ 1006 LZ 1009 LZ 1009 LZ 1009 400 450 450 450 450 500 400 EN 50214 ST Ø 2.5 EN 50214 HTF EN 50214 HTF EN 50214 ST Ø 2.5 EN 50214 HTF G 1.50 16 x 1.00 2 x 2 x 0.50 1 x 2 x 0.50 74.8 x 5.0 6347/3-F 53.0 x 6.4 50.9 x 6.4 HF-2122-F 50.9 x 6.4 8607-F 78.5 x 5.8 7067/2-F 7954/2-F 79.7 x 6.1 7954/2-F 54.1 x 7.1 HF-2122-F 6651-F 64.3 x 7.0 HF-2122-F 6651-F 64.3 x 7.0 HF-2122-F 6651-F 72.8 x 7.0 HF-2122-F 6651-F 168185 8507-F 147 LZ 1006 400 EN 50214 HTF 12 x 2 x 0.50 300/300 44.9 6651-F 54.1 x 5.6 192360 8854/3H 56 LZ 1006 450 EN 50214 ST Ø 2.5 4 x 2 x 0.50 300/300 31.3 6651/3-H 28.0 x 9.0 191093 8512-F 232 LZ 1009 400 EN 50214 ST Ø 2.5 3 G 2.50 450/750 + 14 x 1.00 300/500 + 4 x 2 x 0.50 300/300 80.6 6651-F 79.0 x 5.7 192453 8884-F 58 LZ 1006 400 EN 50214 ST Ø 2.5 8 x 0.75 + 4 x FO 30.2 Stand 11.07.2016 300/500 40.8 x 4.3 GF-2314 Technische Änderungen vorbehalten. FM – PVC – supported Mid rise - travelling height maximum 150m G50/125 Stand 11.07.2016 Technische Änderungen vorbehalten.
© Copyright 2024 ExpyDoc