Development of lithium beam probe and measurement of edge density profile on JT-60U Atsushi Kojima, 小島有志 JAEA 2009/2/18 at ASIPP 1 Introduction Edge Region in H mode Plasma ELMy H mode is a standard operational scenario for ITER. Pressure Before ELM ELM Crash Heat Load to Divertor Pedestal height ~kPa After ELM Pedestal width~cm Current Bootstrap Current by P r/a 0.7 0.8 0.9 1.0 •Short lifetime of divertor target due to type I ELM is a critical problem. =>ELM control techniques (RMP, pellet pacing) and small ELM operations (grassy ELM) are developed. Understandings of Edge plasma physics improves ELM controls and pedestal performance. Edge density profile during ELM cycle was not obtained in JT-60U. To investigate behaviors of edge density and edge current profiles with high time and spatial resolutions, NEW Lithium Beam Probe is developed. 2 Background and Objective 0.15 Toroidal rotation vary ELM size and frequency. →Why and How do ELMs change? small(co) small(bal) small(ctr) middle(co) middle(bal) middle(ctr) large(co) large(bal) large(ctr) q95~4 DWELM/Wped Background: Type I ELM behaviors have been investigated with tangential NBIs (co and counter directions) in JT-60U. PSEP~6 MW e*~0.25 0.1 ITER Maximum tolerable ELM size 0.05 Ctr 0 -100 -50 Co 0 50 100 VT,ped [km/s] Ref: K. Kamiya PFR. 2, 005 (2007). Objective: Development of LiBP with high resolutions (1ms, 1cm) for ELM dynamics Experimental observation of edge density profile during ELM cycle →Understanding of physics for ELM control ELM affected area ~ ELM size DWELM 3 Outline Outline: 1. Development of LiBP on JT-60U • Development of large-current and low-divergence Li beam • Edge density profile measurement using LiBP 2. Type I ELM Dynamics • ELM affected area in Co- and Ctr rotating plasmas 3. Summary 4 Lithium beam probe development on JT-60U. Edge diagnostics using LiBP edge ne from beam emission profile edge j from Zeeman polarimetry resolutions of 1ms and 1cm are desired. Development of Li ion gun Low beam energy ~ 10keV optimum penetration in neped=1~3x1019m-3 small Doppler broadening is a merit for Zeeman spectroscopy (0.08nm splitting@4T) Long Beam Line large beam current ~ 10mA extraction more than 1mA at 6.5m (effective beam intensity) low divergence angle ~ 0.4 degree long beam line, Zeeman spectroscopy Challenging diagnostic Li0 beam ⇒design study by beam simulation 5 Test stand of Lithium Beam System Li Ion Source HVT Na Vapor Neutralizer Ion Gun 70cm XY beam monitor (2.3m) b eucryptite (Li2O・2SiO2・Al2O3) soaking to porous tungsten disk(50mm) Neutralizer + Li0 Li Electron Beam Heating ~1500degC diagnostic region (6.5m) 300degC 6 Li ion gun using EB heated ion source is developed. Li0 Li+ b eucryptite Porous W EB Heating~1500℃ Na heater ~300℃ Mo 50mm 7Li, Beam Current [mA] porosity 30%, Temp~1500℃ Life time~3.5 A・sec (1g) 10kV 50mm EBIS (DIII-D 30keV) 10 JT-60U 10keV, 10mA, 50sec 6mm IS (CHS 15keV) 0.1 Li ion gun is newly developed. 50mm EBH Ion source has capability to extract 10mA Li ion beam. Extractor enables low energy (10keV) large current extraction (10mA). 15mm IS (ASDEX-U 70keV, LHD 20keV) 1 -20kV (Strong Extraction) 10mA, 50sec operation is demonstrated. 0 -10 -20 V extractor [kV] -30 7 A. Kojima, et al 2008 Rev. Sci. Instrum. 79 093502. 3mA, 0.2deg, FWHM=0.05nm Li0 beam is obtained at 6.5m. Effective Beam Intensity ~3mA FWHM of Beam Emission ~0.05nm Intentsiy [a.u] Li0 intensity at 6.5m [mA] 4 3 2 1 0 0 2 4 6 8 10 Extracted Ion Beam Current [mA] 12 1 Vacc=10keV Iacc=3.5mA 0.5 FWHM =0.05nm 0 668.8 w/o Bt, gas injection E48867 3.9T OH plasma + 669.2 669 Wave length [nm] 3mA, 0.2deg Li0 beam is obtained at plasma edge (6.5m from neutralizer) small divergence angle corresponds to good spectrum resolutions. FWHM of spectrum ~0.05nm < Zeeman splitting ~0.08nm@4T Etalon (DlFWHM=0.08nm) and interference (DlFWHM=1nm) filters are utilized. 8 Density profile (L to H mode) is successfully reconstructed. Ip=1.6MA, Bt=3.95T, d=0.34, q95=4.3 ELM free H H Signal [a.u] 0.2 E49228-t4.6 L mode Emission BG E49228-t5.25 H mode Li0 Li0 0.1 Li signal 0 0.7 0.8 0.9 Z along Beam Line [m] 1 0.7 0.8 0.9 Z along Beam Line [m] 3 Beam Chop Density [x1019 m-3] L 0.3 LiBP Thomson H mode 2 1 0 -0.2 L mode -0.15 -0.1 -0.05 R-Rsep [m] 0 Edge density measurement (DR~1cm, Dt~0.5ms) is demonstrated. Not Reconstructed Density profile during ELM cycle can be investigated. 9 1 Density loss fraction (type I ELM) is 30% at pedestal region. Ip=1.6MA, q95=4.3, d=0.34, PNB=11.7MW, bp=0.85, li=0.83, e*= 0.29 recovery 20 Density pedestal recovers in 10ms after ELM crash. -3 m ] e 0 10 time relative to ELM [ms] After ELM 1 t=-1~0ms t=1.5~2ms pivot 0.4 1.6MA Co Thomson ~30% e 0 -10 2 0 0.6 Type I ELM (fELM=37Hz) 2 neped Before ELM e 0.5sec ELM averaging 0 4 -Dn /n DDiv [a.u] e n [10 1 3 19 5cm 4cm 3cm 2cm 1cm n [10 2 19 -3 m ] E49228 t6.5-7.0 0.2 0 -10 -8 -6 -4 R-Rsep [cm] -2 0 • Density pedestal shoulder is 4cm from separatrix. • At pedestal region, density loss fraction due to type I ELM is 30%. 10 Density loss fraction of Ctr-rotation is smaller than Co-. -3 m ] 2 Ip=1.6MA, q95=4.3, d=0.34, fELM=45Hz, PNB=12.9MW, bp=0.81, li=0.83, e*=0.33 1 neped Co e 1 pre-ELM (Co) t=-1~0ms (Ctr) t=1.5~2ms (Ctr) V [100km/s] n [10 19 Ctr pivot t 0 0.6 0.4 1.6MA Ctr 0 -0.5 -1 -20 Co:30% Ctr:20% Vtped~20km/s Vtped~-60km/s -15 -10 -5 R-Rsep [cm] 0 e -Dn /n e 1.6MA Co 0.5 E49228 E49229 0.2 0 -10 0.4 -8 -6 -4 R-Rsep [cm] -2 • Density pedestal width is similar. 4cm~4.5cm from separatrix neped : Co > Ctr 0 • Ctr-rotating plasmas have smaller density loss fraction, 30% (Co) > 20% (Ctr) smaller affected area. YAG Thomson 0.2 0 -15 -10 -5 R-Rsep [cm] 0 11 Ctr-Rotating plasmas have weaker gradient. E49228-Co ion ion 0 200 P Co-rotation -DP /Dr [kPa/m] P 2 100 t= -2.5~0ms t= 10~12.5ms t= 2.5~3ms 4 2 0 200 Ctr-rotation 100 ion ion (CO) > (CO) > 0 Piped (CTR) DPiped/Dr (CTR) Wider gradient profile cause radial expansion of eigen function of unstable mode. ⇔ Small and narrow crash of ctr-rotating plasma may be caused by weaker gradient profile. -4 -2 R-Rsep [cm] 0 8 [kPa] -4 -2 R-Rsep [cm] FWHM=2.3cm 0 -6 i • • Piped DPiped/Dr FWHM=2.6cm ped 0 -6 P -DP /Dr [kPa/m] t= -2.5~0ms t= 10~12.5ms t= 2.5~3ms 4 E49229-Ctr 6 [kPa] [kPa] 6 6 4 2 0 -10 Co Ctr -5 0 5 10 15 time relative to ELM [ms] 12 20 4. SUMMARY 1. Development of lithium beam probe system • 10mA-class lithium beam is developed. • Edge density measurement is successfully demonstrated. 2. Edge density measurement • Edge density profile during type I ELM is observed for the first time. • Small normalized ELM energy loss of ctr-rotating plasma is caused by different pressure profile. • Now, we try to carry out the stability analysis to explain the different ELM size by toroidal rotations. 13 Behavior of edge plasma is obtained during ELM cycle. Edge Diagnostics on JT-60U E49228 t6.8s ne dl1 ne dl2 4 ELM onset E49228 3 Wdia [MJ] LiBP (DR~1cm, D t=0.5ms) 2 CXRS (DR~0.6cm,D t=2.5ms) 0 ECE 3 (DR~1.2cm, D t=20ms) 86kJ 89kJ fELM=37Hz 2.9 2.8 DaDiv [a.u] 2.7 neped (r/a~0.9) [1019m-2] recovery Thomson 2 1 2.4 2.2 Edge ne, Te, Ti during ELM are measured simultaneously with high time and spatial resolutions. Teped (r/a~0.86) [keV] Tiped (r/a~0.88) [keV] 2 1.8 6.8 6.81 6.82 6.83 Time [sec] 6.84 14 6.85 15 ne and Ti loss fractions have different Ip dependence. Ip=1.0MA, q95=4.1, d=0.39, fELM=75Hz , PNB=10.9MW, bp=1.3, li=0.83, e*= 0. 45 1.5 e 3 neped 1 1MA Co 0.5 0 0.6 t= -1~0ms(1MA) t= 2~2.5ms(1MA) 0.4 0 -10 1 1MA Co 1.6MA Co 0.3 0.2 Tiped 1.6MA Co 2 0 0.4 e -Dn /n 1.6MA Co Ti [keV] 2 -DTi/Ti e n [10 19 -3 m ] 2.5 t= -2.5~0ms (1MA) t= 3~5.5ms (1MA) t= -2.5~0ms (1.6MA) t= 3~5.5ms(1.6MA) 1MA Co 1MA Co 1.6MA Co 0.2 0.1 -8 -6 -4 R-Rsep [cm] -2 0 0 -10 -8 -6 -4 R-Rsep [cm] -2 0 • Density pedestal width is ~1cm wider than high Ip case. (bp=0.85->1.3) n/Dn and T/DT have different Ip dependence. Increases of ne and DT (conductive component) is dominant in high Ip case. (DWELMconv~TDn, DWELMcond~nDT) 16 Density Loss due to Grassy ELM is smaller than Type I ELM. fELM=200Hz D 0.2 0.5 2 5 5.02 5.04 5.06 100msec Time [sec] 5.08 -0.6 5.1 0.5 1.5 0 1 -0.5 0.5 0 6.4 fELM=500Hz 6.41 6.42 50msec6.43 Time [sec] 6.44 6.45 -3 1 0.5 e -0.4 m ] -0.2 19 0 1 t= -0.5~0ms (grassy) t= 0.5~1ms (grassy) t= -1~0ms (Type I) t= 2~2.5ms (Type I) 1.5 n [10 1.5 0 (Ip=1.0MA, q95=4.3, d=0.54, PNB=9.4MW) 0.4 0 0.6 -Dne/ne Density [x10 2 D [a.u] Density [x1019 m-3] R-Rsep= -6cm -4cm -2cm 0cm D [a.u] 19 -3 m ] large grassy and small type I ELMs (E48999) Grassy (200Hz) Grassy (500Hz) Type I (75Hz) 0.4 0.2 0 -10 -8 -6 -4 R-Rsep [cm] -2 0 • Difference of grassy and type I ELMs is small Increase of nesep. =>Enhanced recycling from divertor is small. • Grassy ELM (1MA, fELM~200Hz, grassy ELM in mixture ELMs) affects 20% of density, and radial extent is 5cm. (Type I -Dne/ne~30%, 10cm~) 17 • Grassy ELM with higher frequency has smaller crash (<5%~noise level). ion max(-DP /Dr) [kPa/m] 3-2. Evolution of pressure gradient are different. 250 1.6MA Co 200 1.6MA Ctr 1MA Co 150 37Hz 75Hz 100 50 0 45Hz 10 20 time relative to ELM [ms] 30 Evolutions of ion pressure gradient in each case show • Pressure gradient of 1.6MA ctr-rotations (fELM~45Hz) and 1MA co-rotation (fELM~75Hz) cases is not saturated. Pressure gradient may have limit and trigger ELM. •1.6MA co-rotations (fELM~37Hz) case is unclear. pressure gradient and edge current may play a role for the ELM trigger. • Stronger pressure gradient of co-rotation case suggest rotation effect on 18 stability limit. 2-1-2. Reduction of Ion Temperature in Ctr-Rotation is also smaller than Co-Rotation. 2 1 0 -10 0 10 time relative to ELM [ms] 3 Tiped Ti [keV] Ti [keV] 3 E49228 t6.5-7 Co 7cm 6cm 5cm 4cm 3cm Type I ELM (fELM=37Hz) 2cm 2 Ctr 1 20 • ELM loss fraction of ne and Ti is small in ctr-rotation. Observed small normalized ELM energy loss is caused by small loss fraction profile. t= -2.5~0ms (Co) t= 3~5.5ms(Co) t=-2.5~0ms (Ctr) t= 3~5.5ms (Ctr) 0 0.4 pedestal Ti increases monotonically. Co Ctr i 0.3 i -DT /T • Ti pedestal shoulder is located at 4cm~5cm, and the difference is unclear. Co 0.2 0.1 0 -10 -8 -6 -4 R-Rsep [cm] <DWELM/Wped> (Co,Ctr)=(8.2%, 6.1%) -2 19 0 1. Pedestal ne and Ti are observed by newly developed diagnostics (Lithium Beam Probe, Charge eXchange Recombination Spectroscopy). 20 Line density and pedestal density behave different. FIR interferometer (U1 port) ne dl1 n dl e 2 ELM collapse t :crash ~200ms E49228 3 2.5 Density crash and recovery in ELM cycle are observed by profile measurement. FIR interferometer (U2 port) time delay neped [1019m-3] 5.5 Enhanced recycling time delay increase of nesep increase of ∫nedl1 5.3 1.5 ∫nedl2 [1019m-2] U2 port 1 2 5.2 6 ∫nel1 [1019m-2] U1 port 5 1 4 nesep [1019m-3] 0 6.8 Flux to divertor 5.4 2 decrease of neped decrease of ∫nedl2 6.81 6.82 6.83 Time [sec] 6.84 3 6.85 increase of neped Relaxation and Pedestal recovery decrease of nesep t :recover ~10ms Time delay between neped and ∫nedl2 has information of pedestal recovery. 21 Core density recovers the lost density nelIN+OUT 19 Density [10 2 1 -2 m ] 0.2 19 nelIN = -0.15m~pivot point (recovery from crash) DnelIN+OUT nelOUT nelOUT = pivot point~+0.1m (decay of enhanced recycling) DNeL nelIN ~ nelOUT pivot 0 -10 Dnl [10 t=6.810 t=6.812 t=6.815 Before ELM nelIN -3 m ] 3 -5 0 R-Rsep [cm] ELM DDNeL ne dl22 = DnelIN + DnelOUT+DNeL 5 =DnelIN+OUT+DNeL 0 core region ELM 0.1 Dn l IN+OUT e Dn l IN 0 e Dn l OUT e Dn D lne dl2 core -0.1 -0.2 6.8 e 6.81 6.82 6.83 Time [sec] 6.84 6.85 core indicates core density DDn neeldl 2 behavior! drop of D ne dl2 corresponds to 2% density reduction of core region. It may recovers the lost pedestal density. 22 10mAを引き出し、良い温度分布を持つLiイオン源の開発に成功した。 モリブデンマウント 接触面の熱伝導が 悪く、温度が上がら ない 電子ビーム設計 タングステン温 度(℃) 加熱パワー(kW) 設計値 1386.0 1.5 電子加速電圧 (V) 1500.0 ビーム電流(A) 1 温度制限電流 (A/m2) 1360.0 フィラメント温度 (℃) 2096.0 イオン源温度分布 2007年式 電子ビーム加熱 電子ビームで直接加 熱(最大5kW) 1400 H19式>1400℃ 2007年式 H18式 >10mA イオン源温度 [℃] 2006年式 タングステンディスク ヒーター加熱(市販品) 1200 5000倍 1000 800 2006年式 <900℃ <2μA ポーラスタングステン 電子ビーム 600 -40 -20 0 X [mm] フィラメント 20 40 【課題】 ビーム開発はイオン源が命!! 大電流(タングステン表面積・表面温度) 、収束性(タングステン表面温度分布・表 面形状) 、長寿命(タングステン空孔率)、制御性(電子ビームパワー)、メンテナンス 性(イオン源構造)、耐熱性(構造材) 、加熱効率(加熱パワー、放射冷却対策)の要 求全てを満たすイオン源 【工夫】 • 1400度を超える電子ビーム加熱イオン源を独自に設計・製作 • フィラメント形状で温度分布を制御し、収束性の良い中心ピーク分布を実現 • イオン放出面を凹状にして収束性の向上 【結果】 2007年式電子ビーム加熱イオン源で設計値通りの高性能を得た。 23 新型イオン銃で10mA大電流Liビームの50秒間引出を達成した。 10mA、50秒間の長時間引き出し 中性化効率 Na蒸気圧 1 50 0.1 運転温度 280度95% 0 150 200 250 300 中性化セル温度 [℃] 0.01 電子ビームパワー 3 10mA, 50sec 10 2 5 プレ加熱(40秒) 0 -20 0 20 40 Time[sec] 1 60 0 80 【課題】 Naが電極・セラミックスに付着し、急激な絶縁劣化が問題化 10 Na飽和蒸気圧 [Pa] 中性化効率 [%] 100 ビーム電流 [mA] 【特徴・工夫】 1. 収束性 中心ピークの温度分布、凹状放出 面、 電極形状の最適化 2. 低エネルギー・大電流 引出電極で強引出 電場 Ref. Plasma Fusion Res. 2, S1104 (2007) ビーム電流 電子ビームパワー [kW] 15 0.001 350 【工夫】 • Naフラックスが絶縁用セラミックスを見込まないように対策 • 中性化効率95%での最適な運転 【結果】 10keV、10mAの大電流Liビームを50秒間安定に引き出す ことに成功。(電子ビームによる温度分布の緩和時間~10秒程 度) • 引出電極が低エネルギー大電流ビーム引出の鍵。 24 (ビーム電流を制御できる。計測に便利) 到達ビーム電流3mA、0.2度の高輝度・低発散Liビームを実現した。 1 中性化セル0m ビームモニター2.3m 0.1 1 6.5m Li0 670 670.5 671 波長 [nm] ビームの発光スペクトル Li7 Li6 Total Emission Center= 670.0nm 0.5 FWHM= 0.055nm 0 669.9 671.5 670 波長 [nm] 670.1 6.5m到達ビーム電流 [mA] Li+ 0.01 669.5 放射強度 [a.u] LiI (670.78) ビーム成分 放射強度 [a.u] 10 4 到達ビーム電流 到達ビーム電流 3mA ~3mA 3 ビーム径 5cm 発散角 0.2度 2 1 目標値1mA 0 0 2 4 6 8 10 イオンビーム電流 [mA] 12 【課題】 6.5m先でのビーム径を抑え、発散角がゼーマン偏光計測(0.08nm)に有効な ビーム生成・維持。6.5m先で60mmの計測器に合わせるコントロール。 【工夫】 ビームモニター(十字型のワイヤープローブ)によるビーム位置確認 【結果】 発散角0.2度(目標値0.4度)、ビーム径5cm、到達ビーム電流3mA(目標値 1mA) Heガス入射でゼーマン分離よりも小さいスペクトル幅を得て、JT-60に移設した。 25 ⇒世界最大のリチウムビームプローブ To be published to Rev. Sci. Instrum. 漏れ磁場を低減し、ビーム制御手法を確立し、プラズマ計測に成功した。 リチウムイオン銃 比透磁率 飽和磁束密度 SS400(C~ 0.16%) 1000 2T パーマロイ 20000 0.9 T ビーム幅方向の 3ch プロファイルモニ ター 22mm 磁気シールド設計計算 外部磁場300ガウス SS400 mm 中性リチウムビー ム 磁束密度 gauss 10.1 パーマロイ mm 2 磁束密度 パーマロイ mm ビームライン 40 磁束密度 1.03 2 0.185 S1 30 S2 34 S(二層) S3 S(三層) 291 35 162 1 【課題】 JT-60のポロイダルコイルによる漏れ磁場(300ガウス)を1/1000低減する。 6.5m先の22mm幅にビーム中心を合わせるビームコントロール。 XYビームモニター JT-60 【工夫】 • 三層式の磁気シールド(設計では0.2ガウスに低減)を設計・製作 • プラズマ表面にビーム幅方向の分布・位置計測チャンネルを設置 【結果】 ポロイダルコイル通電時も漏れ磁場の影響なく、XYビームモニターでビー ムラインの通過を確認し、プロファイルモニターでさらに詳細に位置を決め、プラズ 26 マ計測に成功した。 1.1MA / 2.5T, d=0.18 3 2 1 0 2 1 0 5.24 2 密度 [x1019 m-3] Da ペデスタル密度 ダイバータ部D ペデスタル密度 [x19 m-3] 世界で初めて周辺局在モードによる密度分布の崩壊を詳細に捉えた。 5.26 Time [s] 5.28 ELMによる 周辺密度崩壊 1 SOL ペデスタル 0 -10 -5 0 セパラトリクスからの距離 [cm] 5 【結果】 世界で初めて周辺局在モード(ELM)による周辺密度分布の崩壊を高時間・空間分解能で SOLからペデスタル領域にわたり詳細に捉えた。 時間分解能<0.5msec、空間分解能<1cm 【意義】 周辺プラズマの構造形成の理解に繋がり、ELMによる粒子・熱流束の定量評価から ITERにおけるダイバータ設計に大きく貢献できる。 27 イオン銃をJT-60に移設し、JT-60プラズマ入射に成功した。 透磁率 真空排気設備 SS400 2T パーマロイ 20000 0.9T 外部磁場[T] 3.0e-2 シールド効果 厚さ(SS400) 40mm S 30 磁束密度[T] 1.01e-3 S2 34 磁束密度[T] 厚さ(パーマロイ) 磁気 シールド 飽和磁束密度 1000 厚さ(パーマロイ) 磁束密度[T] 10 2mm 1.03e-4 2mm 1.85e-5 S(二層) S3 S(三層) 291 35 1621 イオン銃 JT-60の漏れ磁場(300G)を0.1G程度に 抑える磁気シールドを設計した。 ビームライン Liイオン銃、高電位テーブルをJT-60に 移設し、初期調整後プラズマ入射に成功し た。 10mA引出に向けて現在コンディショニン 28 グ中。 設計した入射光学系をJT-60に設置し、計測システムを整えた。 11 計測点 ペデスタル計測に特化し、スポット6mm ペデスタル10ch、Δch=9.5mm コア/SOL10ch、Δch=16mm ビーム幅を含めた分解能は1cm程度 データ収集系 20ch、1MHzサンプリングの高速データ収集系を利用し、密度揺動 計測にも備えている。 29 PEMによる偏光測定 2つのPEM(光弾性変調器)とポラライザーとを組み合わせて、特定波 長の偏光成分を光強度の周波数成分へ変換する。 下図の配置の場合、透過光I3の周波数成分は以下で与えられる(f1 = 20 kHz, f2 = 23 kHz)。J1(•), J2(•)は1次、2次のベッセル関数。f1, 2f1, 2f2は比例定 数。 S y I3 ( f1 ) f 1 3 J1( ) PEM pair 2 x S S I3 (2 f1) 2 f 1 1 2 J2 ( ) 22.5o 2 2 入射光 S S I3 (2 f 2 ) 2 f 2 1 2 J2 ( ) –22.5o 2 2 PEM1 I3(2f1)とI3(2f2)の比から偏光角g 0o PEM2 が分かる。 Polarizer I3(f1)、I3(2f1)、 I3(2f2)から円偏 光と直線偏光の比 tan(2c)=S3/(S12+S22)1/2が分かる。 透過光 I3 z バンドパスフィル ター(+エタロン) 検出器30 (PMT) 1 10 19 0.1 2 0 1 0 4.74 4.76 4.78 Time [s] 4.8 ペデスタル 0 -0.1 -0.05 0 セパラトリクスからの距離 [m] 0.05 Etalon+Filter 0.2 偏光成分強度 [a.u] 密度 [m-3] 小振幅ELM 3 1 Liビームの発光スペクトルBt~4T σ- π 1 σ+ 0.5 0.5 フィルター特性 0 0.2 0 円偏光成分 直線偏光成分 Li Beam Emission 19 Da ペデスタル密度 ダイバータ部D 2 10 ペデスタル密度 [x19 m-3] 小振幅ELMによる密度分布の崩壊、ゼーマン偏光成分の計測に成功した。 これらの比が磁 場のピッチ角に 相当する 0.1 0 -0.1 加速電圧による ドップラーシフト -0.2 -0.3 669.9 10keV 670 7.8keV 670.1 波長 [nm] 670.2 670.3 【結果】 世界で初めて小振幅ELMによる周辺密度分布の崩壊を高時間・空間分解能で捉えた。 加速電圧をスキャンしてドップラーシフトを変更し、ゼーマン偏光成分の基礎データ取得に成功した。 ⇒この手法では加速電圧を変更しても、引出電極によりビーム電流が制御できることが大きく生かさ れた。 【意義】 31 ELMによる粒子・熱流束の定量評価から、ITERにおけるダイバータ設計に大きく貢献できる。 周辺電流計測に利用するゼーマン偏光成分の検出に成功した。 【結果】 半値幅1nmの干渉フィルターと0.1nmのエタロン フィルターを組み合わせて用いることによりLiビー ムのゼーマン偏光成分(半値幅0.06nm)のみを取 り出すことに成功した。 【特徴】 加速電圧を下げても信号強度(ビーム電流)を保つ 事ができるため、 加速電圧をスキャンしてエタロ ンフィルターの調整が効率的に行える。 エタロン、フィルター Etalon+Filter の透過率 エタロン、フィルター の透過率 Etalon+Filter <ゼーマン偏光による周辺電流計測> 2つのPEM(光弾性変調器)と直線偏光器を組み 合わせて、偏光成分(σ-)を光強度の周波数成分 へ変換する。 1 0.75 0.5 0.5 0.25 0 669 669.5 1 670 670.5 波長 [nm] 0 671 1 0.75 0.5 σ- π σ+ 0.5 0.25 0 669.9 0.2 670 670.1 670.2 円偏光成分 直線偏光成分 0 670.3 Li Beam Emission 光ファイバー 偏光成分強度 [a.u] レンズ PEM 1 Li Beam Emission 観測窓 Li Beam Emission Etalon+Filter 直線偏光器 これらの比が 磁場のピッチ 角に相当する 0.1 0 -0.1 加速電圧による ドップラーシフト -0.2 -0.3 669.9 10keV 670 7.8keV 670.1 波長 [nm] 670.2 670.3 32 Liビーム(7.8keV) 視線 5 4 IP Ne D NBI 10 3 D 2 1 ne 5 Ip 0 直線偏光成分 15 0 NBI Power [MW] 0.8MA/3.8T, q95=7.5, d=0.5, Ne average [1019 m -3] IP [MA], D [a.u] L,Hモードでのゼーマン偏光成分信号の検出に成功した。 L,H(12MW),H(15MW) R20, R46 [a.u] 0.005 LiビームOFF 0 -0.005 【目的】 大・小振幅ELM発生時の周辺電流を観測し、 L-Hモードの差~周辺電流? 円偏光成分 周辺電流とELMの関係をからELMの物理機 構を解明する。 -0.01 0 3 6 9 12 Time [sec] Lモード 【結果】 周辺電流計測の基礎データとなるゼーマン 偏光成分のL,Hモードでの違いを得ることが でき、現在解析中である。 Hモード12MW Hモード15MW 33
© Copyright 2024 ExpyDoc